GOODMAN CAUTA3022A3 Evaporator A-Coil | 2 to 2.5 Tons

In stock

The Goodman CAUTA3022A3 2 to 2.5-ton R-32 uncased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAUTA3022A3

2 to 2.5 tons30,000 BTU/h nominal
13 inwidth
R-32refrigerant
R-32Add-on heat pumpUncasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAUTA3022A3
ManufacturerGoodman
Size2 to 2.5 tons
Width13 in
RefrigerantR-32
MeteringTXV

CAUTA3022A3: replace an old central air conditioner with a 13 in Goodman coil of 2 to 2.5 tons

Is your central air conditioner many years old, running on the refrigerant of another era, and are you thinking of replacing it? The Goodman CAUTA3022A3 is an uncased A-shaped evaporator coil running on R-32, whose nominal size of 30,000 BTU/h corresponds to 2 to 2.5 tons. Its 13 in width suits furnaces with a narrow outlet.

It is installed by our crews in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, often during complete replacements.

The real subject: a new system, not an isolated part

The coil of an old air conditioner and its outdoor unit form a pair. When one of the two gives out, it is rarely wise to change only the other. R-32 also requires pairing the coil with an outdoor unit using the same fluid. That is why we always propose replacing the complete system, in a single visit.

The CAUTA3022A3 is the indoor half of this pair. It goes in the furnace plenum, while the Goodman outdoor unit of the same capacity sits outside, on a stand.

A 2 to 2.5 ton size: who is it for?

This size suits homes more spacious than those in the 1.5 to 2 ton size: two-storey cottages, large bungalows, semi-detached homes with several bedrooms. In these cases, the cooling load is larger and a more generous coil is called for.

We do not pick the biggest just in case, though. A load calculation is based on the walls, windows, exposure and ventilation of your home. If the result falls below the size, we propose a smaller model from the series, because an oversized unit shuts off too soon and leaves the air damp.

Thirteen inches: an asset in cramped mechanical rooms

It is fairly common for a good-sized home to have a furnace with a narrow outlet. This happens when the furnace was chosen for its small footprint rather than its capacity. For these cases, the 13 in of this coil avoids building a transition and simplifies the installation.

If your furnace is wider, two other versions of the same capacity exist: the CAUTA3022B3 in 16-1/2 in and the CAUTA3022C3 in 20 in. We measure before deciding.

What happens in the plenum

Two sloped faces form the A. The furnace air passes through them, the refrigerant evaporates in the tubes under the control of a TXV metering device, and the heat of the air is absorbed. The moisture that condenses is collected in the pan, then removed through the drain.

Uncased, the coil is installed in the existing plenum or in a casing made to the measurements of the space. It can be set in upflow or downflow position.

And heating? The coil plays a part there too

If you pair it with a heat pump rather than a simple air conditioner, the same coil serves to heat in winter. The furnace then stays in place as backup heat. You can therefore use the replacement of your air conditioner to move to a two-season solution, without redoing the ducts.

Choosing within the CAUTA series

  • Capacity: 1.5 tons (CAUTA1818A3 and B3), 1.5 to 2 tons (CAUTA2422A3, B3, C3) or 2 to 2.5 tons (CAUTA3022A3, B3, C3: the family of this page);
  • Width: 13 in (A3), 16-1/2 in (B3) or 20 in (C3);
  • Everything else is common: R-32, TXV metering device, uncased.

The CAUTA3022A3 is therefore the smallest width of the largest capacity in the series.

Efficiency: what the coil does not tell you on its own

The SEER2, EER2 and HSPF2 ratings are not attached to the coil. They characterize a certified match-up, identified by an AHRI number, and that number is what we confirm before ordering. When comparing two offers, it is to this number that you should turn.

The ENERGY STAR list, when we last consulted it, contained no R-32 match-up with this coil. AHRI remains the reference for the outdoor unit chosen.

Signs that a replacement should be considered

An air conditioner that is running out of breath gives clues: the air from the registers is less cold, the unit runs nonstop on hot days, the house stays damp, the electricity bill climbs. It also happens that the indoor coil is clogged or that the condensate pan lets water through. When several of these signs pile up, it is a good time to compare a new system with one more repair.

During the visit, we examine the old coil, note its condition and show it to you if needed. That way, the decision rests on what you see with your own eyes.

The manufacturer

Goodman is a brand of Daikin Comfort Technologies, which also includes the Daikin and Amana brands. Its R-32 coils are made for new-generation heat pumps and central air conditioners, on a furnace or on a modular blower.

CAUTA3022A3 characteristics

  • uncased evaporator coil of the CAUTA line;
  • nominal size 2 to 2.5 tons (30,000 BTU/h);
  • R-32 refrigerant, leak sensor designed for the life of the coil;
  • width of 13 in;
  • liquid 3/8 in, suction 3/4 in;
  • TXV metering device;
  • upflow or downflow installation;
  • 10-year limited warranty on parts, with online registration within 60 days not required in Quebec.

How a replacement goes at AirGreen

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. For a replacement, we:

  • measure the furnace and check the blower and the electrical panel;
  • remove the old coil and install the new one, with leak-tight joints;
  • set the outdoor unit, braze the piping, test with nitrogen and pull a vacuum;
  • reconnect the condensate drain and the thermostat;
  • start everything up, adjust the airflow and explain how it works.

To check before ordering

  • The width of the furnace outlet: 13 in for this model.
  • The airflow the blower can actually deliver.
  • The refrigerant of the outdoor unit: R-32, like the coil.
  • The AHRI number of the match-up.

After the installation: what we leave you with

At the end of the job, we explain the thermostat, the location of the drain and how often to change the filter. We also leave you a written summary of the airflow settings chosen, so that you can show it to another technician if the need ever arises.

Incentives

Hydro-Québec assesses the complete system and not the isolated coil for its programs. We consult the official list at the time of the quote, according to the installation date, and present clearly what applies to your case.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAUTA3022A3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAUTA3022A3
TypeUncased evaporator coil
LineCAUTA
Nominal size2 to 2.5 tons (30,000 BTU/h)
RefrigerantR-32
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D13 in
Model numberCAUTA3022A3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 13 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2 to 2.5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom