GOODMAN CAUTA3022B3 Evaporator A-Coil | 2 to 2.5 Tons
The Goodman CAUTA3022B3 2 to 2.5-ton R-32 uncased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAUTA3022B3
514 316-2973 · sales@airgreen.ca
Quick facts
CAUTA3022B3: a Quebec winter with a 2 to 2.5 ton, 16-1/2 in Goodman coil on your furnace
In Quebec, a heat pump is judged in January. The Goodman CAUTA3022B3 is the indoor coil that lets a central heat pump connect to the air system of an existing furnace. It is A-shaped, uncased, runs on R-32, with a nominal size of 30,000 BTU/h that corresponds to 2 to 2.5 tons, and a width of 16-1/2 in.
We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, in homes where people want to rely less on electric heating without giving up the furnace.
The role of the coil when it is cold
In summer, the coil acts as the evaporator: it removes heat from the air of the house. In winter, with a heat pump, the cycle reverses. The outdoor unit captures heat from the outside air, the refrigerant carries it indoors, and the coil gives it to the air moving through your ducts. The same unit cools in summer and heats in winter.
Because the coil sits in the path of the furnace air, the heat is distributed through the same registers as before. No new duct is needed.
The furnace keeps a role: backup
A heat pump loses efficiency as the cold intensifies. In an “add-on” installation, the furnace therefore stays in place with its blower, its filters and its heating elements. It takes over when the outdoor temperature drops below a threshold that we set together.
This threshold is a matter of balance: too low, and you use more energy than necessary with the furnace. Too high, and the heat pump works when it is less efficient. We set it according to the insulation of your home, your electricity rate and your tolerance for the cold.
Why 2 to 2.5 tons for this type of home
The 2 to 2.5 ton size suits homes large enough to need sustained heating and cooling output, such as a two-storey cottage or a large bungalow. A house of this size benefits from a sturdier system in the warm season. But we repeat: the load calculation decides. If the house calls for less, we propose a smaller size from the series.
Comparing with the CAUTA neighbours
Within the same 2 to 2.5 ton capacity, you can choose among three widths:
- CAUTA3022A3: 13 in;
- CAUTA3022B3: 16-1/2 in, this page;
- CAUTA3022C3: 20 in.
For smaller homes, the CAUTA2422 (1.5 to 2 tons) and CAUTA1818 (1.5 tons) exist in 13 in and 16-1/2 in, and the CAUTA2422C3 in 20 in. R-32, the TXV metering device and the uncased design do not change from one model to the next.
A January evening, in practice
Imagine a January evening in Longueuil, with a clear sky and a sharp cold that is not extreme. The thermostat calls for heat. The outdoor unit starts, draws what heat is left in the outside air and sends it indoors through the refrigerant piping. The coil passes it to the air the blower circulates. The registers blow a soft, steady warmth, without the jolts of electric elements.
If the temperature drops overnight below the agreed threshold, the furnace kicks in as well. You touch nothing: the whole system switches from one mode to the other on its own and you keep the house at the desired temperature.
Measuring the right width
The CAUTA3022B3 is 16-1/2 in wide. The furnace outlet must be of that order so that the air passes through the whole coil. When this is not the case, we build an insulated transition on site, or we propose moving to another width.
Winter efficiency ratings
The HSPF2 ratings, which describe heating performance, as well as the SEER2 and EER2 ratings for cooling, are not attached to the coil alone. They describe a certified system, with an AHRI number. We confirm that number before placing the order.
The ENERGY STAR list contained, when we last checked, no R-32 match-up with this coil. We therefore refer you to the AHRI directory for the outdoor unit chosen.
And in summer, the same coil cools
When the warm season returns, the coil resumes its role as evaporator. The air of the house, warmer than the refrigerant evaporating in its tubes, gives up its heat to it. The water the air contained condenses on the fins and goes to the drain. The result is a cool house, and above all a less damp one, with a single unit and a single thermostat for both seasons.
Why uncased, and why Goodman
The CAUTA3022B3 is supplied uncased: we insert it into the existing plenum or into a casing made to the measurements of the space. This is useful when space is tight or the plenum is in good condition. Goodman, a brand of Daikin Comfort Technologies along with Daikin and Amana, designs its R-32 coils for new-generation heat pumps and central air conditioners, on a furnace or on a modular blower.
CAUTA3022B3 technical data
- CAUTA line, uncased coil;
- nominal size 2 to 2.5 tons (30,000 BTU/h);
- R-32 refrigerant; leak sensor designed for the life of the coil;
- width of 16-1/2 in;
- liquid 3/8 in, suction 3/4 in;
- TXV metering device;
- upflow or downflow installation;
- 10-year limited warranty on parts; registration within 60 days is not required in Quebec.
Our installation steps
AirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. Here is how we proceed:
- taking the furnace measurements, checking the blower and the electrical panel;
- setting the coil and sealing the connections leak-tight;
- installing the outdoor unit, brazed piping, nitrogen test, vacuum;
- connecting the drain and the thermostat;
- startup, adjustment of the airflow and of the backup threshold, demonstration.
Our promise on the load calculation
Before writing anything into a quote, we calculate the heating and cooling load of your home. If the 2 to 2.5 ton range is too generous, we say so and propose a smaller model from the series. If it is right, we specify where the match-up falls within that range. You receive the result in writing.
Before deciding
- Measure the furnace outlet: 16-1/2 in for this model.
- Check with us that the blower provides the required airflow.
- Plan for an R-32 outdoor unit, installed at the same time.
- Ask for the AHRI number.
Incentives
The complete system, and not the coil alone, is assessed by Hydro-Québec programs. At the time of the quote, we consult the official list according to the installation date, then tell you what is coming to you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and prepare a written quote for the complete Goodman system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CAUTA3022B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 16-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2 to 2.5-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.