HAXXAIR DC31D2J Evaporator A-Coil | 2 Tons
The Haxxair DC31D2J 2-ton R-454B cased coil sits on your furnace and, matched with the Haxxair HVHDZ-24V2D outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberDC31D2J
514 316-2973 · sales@airgreen.ca
Quick facts
Haxxair DC31D2J: the 2-ton evaporator coil that gives small furnaces a second wind
Picture a duplex in Longueuil, a compact bungalow in Laval or a townhouse on the Plateau: a furnace in the basement, ductwork serving every room, and summers still spent with window air conditioners. The Haxxair DC31D2J evaporator coil is the part that changes that routine. It is a cased A-coil rated at 2 tons (24,000 BTU/h), it runs on R-454B refrigerant, and it mounts directly on your existing furnace.
Connected to the Haxxair HVHDZ-24V2D outdoor unit, it cools your home in summer. With a heat pump, it also heats in winter through the same ductwork. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Which homes this size makes sense for
Two tons is the smallest size in the series. It is aimed at homes where the cooling load stays modest: a townhouse, a small bungalow, or a plex unit that has its own furnace.
The temptation is to go bigger "just to be safe." That is a common mistake. An oversized system reaches the set temperature in a few minutes, then shuts off before it has removed the moisture from the air. The result is a house that feels cool but clammy. A well-sized system runs longer, dries the air and does not create cold drafts near the vents.
Our visit is first about confirming that load. If the calculation points to a larger size, we will tell you plainly: the decision rests on the house, not on what is sitting on the shelf.
An A-coil in its insulated cabinet
The coil has two slanted faces that meet at the top. Air from the furnace rises through the centre and passes through both faces. The insulated cabinet wraps the whole assembly: it sits on the furnace like a ready-to-fit part, which speeds up installation and limits air leaks around the coil.
The manufacturer lists two positions: upflow (standard) and downflow, with the separately sold DWNFLWP-175 kit. The metering device is a TXV R-454B (J), a valve that adjusts the refrigerant flow to the actual load at any given moment.
What happens in the plenum, season after season
In summer, the refrigerant evaporates inside the coil tubes and absorbs heat from the air passing through. Moisture condenses on the fins, drops into the pan and leaves through the 3/4 in NPT condensate drain.
In winter, with a heat pump, the cycle reverses. The refrigerant, warmed by the outdoor unit, gives up its heat to the air in your home. The furnace keeps its blower and its filters and takes over only when the outdoor temperature falls below the threshold we set with you.
Turning an electric furnace into a central heat pump
This is the most common project for this model. An electric baseboard or furnace converts each kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from outdoors to indoors: in mild temperatures, it delivers two to three times more heat than the electricity it uses. That efficiency drops as it gets colder, which is why keeping the furnace as backup for the coldest days makes sense.
The same project replaces a tired old central air conditioner. Rather than repair a unit that runs on a different refrigerant, we install a new, matched system, coil and outdoor unit together.
The numbers that belong to the system, not the coil
The DC31D2J has no efficiency rating of its own. Ratings belong to the certified system, tied together by an AHRI number. Paired with the HVHDZ-24V2D unit, the system carries AHRI 218160009, with a SEER2 of 16.0 and an HSPF2 of 8.2. The outdoor unit delivers 24,000 BTU/h in cooling and 24,000 BTU/h in heating at 47 °F.
When you compare two quotes, ask for the AHRI number on each: it is what lets you compare complete systems, and it is what subsidy programs look up.
DC31D2J or a neighbouring model in the DC series?
The series has four cased coils, all using R-454B and all with a TXV R-454B (J). What changes is the size and the matching outdoor unit.
- DC31D2J: 2 tons, paired with the HVHDZ-24V2D unit. The choice for small spaces.
- DC37D3J: 3 tons, paired with the HVHDZ-36V2D unit, for larger homes.
- DC49B3J: 4 tons, 21 in wide, paired with the HVHDZ-48V2D unit.
- DC61C4J: 5 tons, 24-1/2 in wide, paired with the HVHDZ-60V2D unit.
You do not pick a coil larger than the outdoor unit, or the other way around: the two are sold as a pair. The right approach is to start from the load of the house, then let the size follow.
DC31D2J specifications
- type: cased evaporator coil, DC series;
- size: 2 tons (24,000 BTU/h);
- refrigerant: R-454B;
- net weight: 41 lb;
- liquid line connection: 3/8 in ODS; suction connection: 3/4 in ODS;
- condensate drain: 3/4 in NPT;
- metering device: TXV R-454B (J);
- warranty: 10-year limited warranty on the coil, with registration (Aspen).
With A2L-class refrigerants, a refrigerant detection system (RDS) is required. The Aspen A2LZS or A2LZR kit (with relay) is installed at the factory or on site, and the RBL list includes the A2LZR kit.
How the installation goes at your home
AirGreen is a heating and cooling company based in Montreal; our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and its outdoor unit, here is the essence of the job:
- we measure the furnace and check the blower and the electrical panel;
- we mount the coil in the plenum, with a transition built on site if needed, and seal the connections;
- we install the outdoor unit on a pad or bracket, braze the piping, pressure-test with nitrogen and pull a vacuum;
- we connect the condensate drain and the thermostat;
- we commission the system, set the airflow and explain how it works.
Frequently asked questions about this coil
Can it heat? Yes, when paired with a heat pump. With a central air conditioner, it only cools.
Can I keep my current air conditioner? Usually not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.
My furnace is a different width. What then? We measure it and, if needed, build an insulated transition on site.
What to check before you buy
- R-454B requires an outdoor unit with the same refrigerant, installed at the same time.
- The published ratings apply to the certified pairing, not to the coil alone.
- The blower must deliver the airflow the system needs, and the furnace width must be suitable: we confirm both at the visit.
LogisVert subsidy
The paired Haxxair system appears on Hydro-Québec’s list of eligible heat pumps. Eligibility depends on the complete system and the installation date. We check the official list when we prepare your quote and put the application together with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Haxxair system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The DC31D2J sits in the plenum of a furnace or air handler. Connected to the Haxxair HVHDZ-24V2D outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Haxxair HVHDZ-24V2D outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- We check the furnace width before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
HAXXAIRSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Haxxair coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.
