HAXXAIR DC37D3J Evaporator A-Coil | 3 Tons

In stock

The Haxxair DC37D3J 3-ton R-454B cased coil sits on your furnace and, matched with the Haxxair HVHDZ-36V2D outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDC37D3J

3 tons36,000 BTU/h nominal
casedtype
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 218160010
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDC37D3J
ManufacturerHaxxair
Size3 tons
RefrigerantR-454B
MeteringTXV R-454B (J)
Outdoor unitHVHDZ-36V2D

DC37D3J, the 3-ton Haxxair evaporator coil: the middle of the range and often the right compromise

When a customer in Brossard or Saint-Eustache calls us to replace an old central air conditioner, the question almost always comes up: "What size do I need?" For a good share of the bungalows and cottages in the region, the answer lands around 3 tons. The Haxxair DC37D3J evaporator coil fills that slot: 36,000 BTU/h nominal, insulated cabinet, A shape, R-454B refrigerant.

It mounts on a furnace or a blower cabinet and pairs with the Haxxair HVHDZ-36V2D outdoor unit. We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Our visit, step by step

Before recommending this coil, we follow the same approach every time.

  • We take the width of the furnace and look at the space available in the plenum.
  • We check the blower: it is the part that has to push the required airflow through the coil.
  • We examine the electrical panel and the spot where the outdoor unit will go.
  • We calculate the load of the house room by room, rather than relying on floor area alone.

If that calculation shows that a neighbouring size suits you better, we say so. A heat pump that is too big heats or cools in short cycles and leaves moisture in the house; one that is too small works non-stop.

What this coil does day to day

Air from the house rises toward the furnace, passes through the coil and comes out cooled in summer. The water removed from the air condenses, drops into the pan and leaves through the 3/4 in NPT drain. If a heat pump is connected, winter reverses the path of the heat: the outdoor unit picks it up outside and the coil releases it into the existing ductwork.

The furnace does not disappear for all that. It keeps its blower, its filters and its role as backup heat, switching on below an outdoor temperature threshold that we set with you. This is what is called an "add-on" heat pump.

The certified system around the DC37D3J

A coil on its own has no efficiency rating. Ratings attach to the complete system. Here, the DC37D3J coil and the HVHDZ-36V2D unit make up the AHRI 218160010 system, with a SEER2 of 16.5 and an HSPF2 of 8.2. The outdoor unit delivers 34,000 BTU/h in cooling and 34,000 BTU/h in heating at 47 °F.

Haxxair also states that its pairings are ENERGY STAR cold climate certified for Canada, with a continuously variable speed compressor and R-454B refrigerant, which has a GWP of 470.

How it compares with its neighbours

In Haxxair’s DC series, each coil is tied to a single outdoor unit. Here is how the DC37D3J compares.

  • Smaller: DC31D2J, 2 tons, with the HVHDZ-24V2D unit. It suits compact spaces.
  • This model: DC37D3J, 3 tons, with the HVHDZ-36V2D unit.
  • Larger: DC49B3J, 4 tons, 21 in wide, with the HVHDZ-48V2D unit.
  • Largest: DC61C4J, 5 tons, 24-1/2 in wide, with the HVHDZ-60V2D unit.

All share the same TXV R-454B (J) metering device and the same refrigerant. Since the DC37D3J and the DC31D2J have the same 3/4 in ODS suction connection, moving from one to the other does not change the piping logic; the load calculation is what decides.

Why an electric furnace benefits from this project

An electric furnace turns electricity into heat on a one-for-one basis. A heat pump moves heat instead of making it: in mild temperatures, it delivers two to three times more heat than the energy it uses. The colder it gets, the more that efficiency drops, and the furnace then takes over.

In summer, the same installation replaces window air conditioners. One outdoor unit, cool air in every room, a single thermostat for both seasons.

When to plan the work

Many homeowners wait for the first heat wave to call, and that is when schedules fill up. A central air conditioner replacement is better prepared in spring or fall: the furnace is easy to reach, and we take the time to measure, order the right pairing and check subsidy eligibility before the hot season.

If your furnace is electric and you are thinking of converting it, fall is also a good time to compare last winter’s heating bills with what a heat pump could change. Bring them to the visit: they help us set the threshold at which the furnace takes over.

DC37D3J specifications

  • type: cased evaporator coil, DC series;
  • size: 3 tons (36,000 BTU/h);
  • refrigerant: R-454B;
  • net weight: 51 lb;
  • liquid line connection: 3/8 in ODS; suction connection: 3/4 in ODS;
  • positions: upflow (standard); downflow with separately sold kit (DWNFLWP-175);
  • warranty: 10-year limited warranty on the coil, with registration (Aspen).

Leak detection is a requirement for A2L refrigerants: a refrigerant detection system (RDS) is required, and the Aspen A2LZS or A2LZR kit (with relay) is installed at the factory or on site. The RBL list includes the A2LZR kit.

What our installation includes

At AirGreen, a heating and cooling company based in Montreal, refrigeration, ventilation and electrical work is covered by our RBQ licence 5645-9605-01. For this system:

  • mounting the coil in the plenum, with a custom transition if needed;
  • the outdoor unit on a pad or bracket, brazed piping, nitrogen test and vacuum;
  • connecting the drain and the thermostat;
  • commissioning, airflow adjustment and a clear explanation of how it works.

Three questions we often hear

Can my old air conditioner stay? Usually not: R-454B requires the outdoor unit specified for this coil.

Is the furnace still useful? Yes, as backup heat during the coldest weather.

Does this coil heat on its own? No: it heats only when paired with a heat pump. With a central air conditioner, it cools.

Points to confirm before ordering

  • The outdoor unit must use the same refrigerant and be installed at the same time.
  • The published ratings apply to the certified pairing.
  • The furnace width and the blower capacity are confirmed on site.

LogisVert subsidy

The paired Haxxair system appears on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation. We consult the official list when we prepare the quote and put the application together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Haxxair system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The DC37D3J sits in the plenum of a furnace or air handler. Connected to the Haxxair HVHDZ-36V2D outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Haxxair HVHDZ-36V2D outdoor unit
Certified systemMatched with the HVHDZ-36V2D, the system carries AHRI 218160010.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerHaxxair
ModelDC37D3J
TypeCased evaporator coil
LineDC
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV R-454B (J)
Liquid connection3/8 in ODS
Suction connection3/4 in ODS
Net weight51 lb
Matched outdoor unitHVHDZ-36V2D
System AHRI number218160010
System SEER2 / HSPF216.5 / 8.2
Model numberDC37D3J
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • We check the furnace width before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
HAXXAIR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Haxxair coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.