MIDEA MCPM3036BN10TH Evaporator A-Coil | 3 Tons
The Midea MCPM3036BN10TH 3-ton R-454B cased coil sits on your furnace and, matched with the Midea MDV-V18WMN10T outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberMCPM3036BN10TH
514 316-2973 · sales@airgreen.ca
Quick facts
MCPM3036BN10TH: the 3-ton Midea evaporator coil for narrow 17-1/2 in furnaces
In many basements across Montreal, Laval and Longueuil, the furnace doesn’t have much width to spare. The Midea MCPM3036BN10TH evaporator coil was designed for that situation: its cabinet is 17-1/2 in wide, the narrowest of the four coils in this series that we carry. It is part of the ATOM X line, runs on R-454B refrigerant and has a nominal size of 3 tons, or 36,000 BTU/h.
Our team installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Here is what you need to know to decide whether it suits your home.
What this coil does, in plain terms
The coil is the part that exchanges heat with the air in your home. It sits in the plenum, right above the furnace or the blower cabinet. Air passes through its cold tubes, cools down, loses some of its humidity, then goes back out through your vents. The water that collects runs down the pan to the drain.
On its own, it produces nothing: it relies on the outdoor unit, which sends it refrigerant. For the MCPM3036BN10TH, the matching outdoor unit is the Midea MDV-V18WMN10T. The two units are selected, ordered and installed together.
Cooling only, or heating too
With a central air conditioner, the job stops at summer cooling. With a heat pump, the same coil works in the other direction in winter and warms the air moving through your ductwork. The system is an “add-on” type: the heat pump is added to your existing furnace instead of replacing it.
In practice, this opens up three common scenarios:
- converting an electric furnace to a central heat pump;
- replacing an old central air conditioner with a new system;
- keeping the furnace as backup heat for the coldest days.
Why the 17-1/2 in width matters so much
A coil that is too wide for the furnace means building a transition. It can be done, and we build an insulated transition on site when needed, but a width that matches the furnace makes the job simpler and leaves fewer connections to seal.
The cabinet is 17-1/2 in wide, 20 in high and 21 in deep. Its installation position is multiposition. Before ordering, we measure the furnace: it is the only reliable way to know whether this model slides straight in.
Four possible outdoor units: which one to choose?
This is one of the distinctive features of this model. Midea certifies it with four outdoor units, each with its own AHRI number:
- MDV-V18WMN10T, AHRI 216046591, cooling 18,000 BTU/h, heating 18,000 BTU/h at 47 °F, SEER2 15.2, HSPF2 9.1;
- MDV-V24WMN10T, AHRI 216054429, cooling 23,000 BTU/h, heating 24,000 BTU/h at 47 °F, SEER2 16.0, HSPF2 8.6;
- MDV-V30WMN10T, AHRI 216046593, cooling 30,000 BTU/h, heating 30,000 BTU/h at 47 °F, SEER2 16.0, HSPF2 9.0;
- MDV-V36WMN10T, AHRI 216046594, cooling 34,000 BTU/h, heating 36,000 BTU/h at 47 °F, SEER2 16.0, HSPF2 8.9.
A small, well-insulated bungalow doesn’t have the same needs as a two-storey home with large windows. That is why we don’t impose a random pairing: we look at the floor area, the insulation and the available airflow, then choose the matching outdoor unit.
Reading the efficiency ratings correctly
The coil has no efficiency rating of its own. The SEER2 and HSPF2 ratings above belong to the matched system, meaning a specific coil paired with a specific outdoor unit. The AHRI number is the link between the two. If another company gives you a quote, ask for this number: it lets you compare two quotes on the same basis.
The MCPM3036BN10TH compared with the others in the series
Four Midea coils in this series sit side by side, all cased, all on R-454B and all with a TXV. What sets them apart is capacity and width:
- the MCPM3036CN10TH offers the same 3-ton size, but in a 21 in wide cabinet;
- the MCPM4860CN10TH steps up to 5 tons, with a 21 in width and an MDV-V48WMN10T outdoor unit;
- the MCPM4860DN10TH is a 5-ton coil that is 24-1/2 in wide, paired with the MDV-V60WMN10T.
If your furnace is narrow and 3 tons of capacity is enough, the BN is the logical choice. If it is wider, the 3-ton CN avoids narrowing or widening anything.
A system that works all year
In summer, a single outdoor unit replaces window units and sends cool air to every room through the ducts you already have. One thermostat controls everything, in both the warm and cold seasons. In winter, the heat pump provides the base heat and the furnace stays available for the harshest days.
The expansion device and safety
This coil is fitted with a TXV, which meters the refrigerant sent into the tubes according to demand. The manufacturer’s sheet also mentions compatibility with a refrigerant detector suited to R-454B. The connections are 3/8 in for the liquid line and 3/4 in for the suction line.
Questions we are often asked
Can I keep my current air conditioner? Generally not. This coil runs on R-454B and needs the outdoor unit that Midea specifies. We therefore install the complete system, which avoids mixing two generations of equipment.
My furnace isn’t 17-1/2 in wide. What happens? Nothing serious. We take measurements at your home and, if needed, build an insulated transition on site. It is better to find out at the visit than on delivery day.
Will my furnace still be useful? Yes. It keeps its blower, its filters and its role as backup heat. Together with you, we set the outdoor temperature below which it takes over from the heat pump.
Is the coil alone eligible for a rebate? No, eligibility depends on the matched system. That is why we always talk about the coil and outdoor unit as a set.
Quick spec sheet
- model: MCPM3036BN10TH, ATOM X line;
- type: cased evaporator coil;
- nominal size: 3 tons (36,000 BTU/h);
- refrigerant: R-454B;
- dimensions W × H × D: 17-1/2 × 20 × 21 in;
- warranty: 10 years compressor, 10 years parts, 10 years labour (Midea 2025 list, Descair).
What our installation includes
AirGreen is a heating and cooling company based in Montreal, holding RBQ licence 5645-9605-01. For this system, our work always follows the same sequence:
- a preliminary visit to measure the furnace and examine the blower and the electrical panel;
- installation of the coil in the plenum and sealing of the connections;
- outdoor unit on a base or bracket, brazed piping, nitrogen test and vacuum;
- connection of the condensate drain and the thermostat;
- commissioning and airflow adjustment, with an explanation at your home.
Before you buy, check these points
- an R-454B coil can only be paired with an outdoor unit using the same refrigerant;
- the blower must be able to deliver the system’s airflow;
- rebates are calculated on the complete system, never on the coil alone.
LogisVert rebate
The matched Midea system appears on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list when we prepare your quote and put the application together with you.
Get your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Midea system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The MCPM3036BN10TH sits in the plenum of a furnace or air handler. Connected to the Midea MDV-V18WMN10T outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Midea MDV-V18WMN10T outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
MIDEASee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Midea coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.