MIDEA MCPM4860CN10TH Evaporator A-Coil | 5 Tons
The Midea MCPM4860CN10TH 5-ton R-454B cased coil sits on your furnace and, matched with the Midea MDV-V48WMN10T outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberMCPM4860CN10TH
514 316-2973 · sales@airgreen.ca
Quick facts
MCPM4860CN10TH: a 5-ton Midea evaporator coil, 30 in high, for larger homes
When a home spreads over several levels, the basement has been finished and an addition has been built over the years, capacity becomes more important. The Midea MCPM4860CN10TH evaporator coil meets that need with a nominal size of 5 tons, or 60,000 BTU/h. Its cabinet is 21 in wide by 30 in high, it belongs to the ATOM X line and it uses R-454B refrigerant.
We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, for homeowners who want air conditioning, and heating with a heat pump, without redoing their ductwork.
What 5 tons asks of the home
A large capacity is not just a catalogue choice. Two things get checked first:
- the electrical service, which must accommodate the outdoor unit’s circuit;
- the air distribution, meaning ducts and a blower able to reach the airflow the system calls for.
We examine both at the visit. And if the picture of the home suggests that two more modest systems would serve it better than one big one, we tell you frankly, even if it changes the quote.
How the coil fits with the furnace
The coil is A-shaped and sits in the plenum, in the path of the air heated or cooled by your blower. Its insulated cabinet is delivered ready to install. The full dimensions are 21 in wide, 30 in high and 21 in deep, in a multiposition configuration.
The 30 in height is something to measure: a low plenum or limited space above the furnace can complicate things. We check it on site before any order. As for the 21 in width, it must match that of the furnace; otherwise, we build an insulated transition.
Who is this model relevant for?
The typical profile is a large property: a finished basement where people really live, an added storey, a cathedral-ceiling living room or a sunroom turned into living space. These spaces add air volume to treat, often without the original furnace having been reviewed. It is the largest common residential size, and it deserves a serious look before it is chosen.
In Laval or on the North Shore, where large homes are common, we often see this scenario. On the South Shore and in Montreal, it shows up more in extended homes or plexes where several levels are occupied.
What we look at during the visit
We start with the furnace: its width, the condition of the plenum, the blower’s capacity. We then move on to the electrical panel, because the outdoor unit needs its own circuit. Finally, we go through the main ducts to judge whether air can circulate at the required airflow. A written quote follows, with the complete Midea system and its AHRI number.
Two outdoor units to choose from
The MCPM4860CN10TH pairs with two certified Midea outdoor units:
- MDV-V48WMN10T, AHRI 216054430, cooling 48,000 BTU/h, heating 48,000 BTU/h at 47 °F, SEER2 16.0, HSPF2 8.9;
- MDV-V60WMN10T, AHRI 216054431, cooling 52,000 BTU/h, heating 54,000 BTU/h at 47 °F, SEER2 16.0, HSPF2 8.9.
The efficiency ratings go with the set, not with the coil alone. When you compare quotes, the AHRI number tells you whether you are really talking about the same system.
Between the 5-ton CN and DN
The series has two 5-ton coils. This one is the narrower of the two:
- the MCPM4860CN10TH is 21 in wide and comes with the MDV-V48WMN10T outdoor unit;
- the MCPM4860DN10TH is 24-1/2 in wide and comes with the MDV-V60WMN10T.
The two 3-ton coils in the series, the MCPM3036BN10TH and the MCPM3036CN10TH, are smaller in capacity. The BN fits in 17-1/2 in, the CN in 21 in. All have a TXV, a cabinet and the same refrigerant, so the decision comes down to capacity and the width of your furnace.
What the coil does, season after season
In summer, the refrigerant evaporates in the tubes, absorbs heat from the air passing through and dries the home slightly; the condensation runs to the drain. In winter, with a heat pump, the direction of the cycle reverses and the air receives the heat captured outdoors. The furnace serves as backup when the temperature drops below a threshold that we set with you.
With a central air conditioner, the function remains cooling only. The heat pump is what adds heating.
What changes when you replace the old equipment
Replacing an old central air conditioner with a new system, or switching from an electric furnace to a heat pump, redistributes your heating costs. Part of the season shifts to the heat pump, which moves heat instead of making it. The furnace stays there for the cold peaks. Since the system is controlled by a single thermostat, you keep simple operation.
A matter of patience when choosing
Equipment of this size isn’t chosen in a rush. Take the time to compare quotes, to ask for the AHRI number of each system and to ask your questions about airflow. We would rather answer ten questions before signing than explain a surprise after installation.
Spec sheet
- model: MCPM4860CN10TH, ATOM X line;
- type: cased evaporator coil;
- nominal size: 5 tons (60,000 BTU/h);
- refrigerant: R-454B, with TXV;
- connections: 3/8 in liquid, 3/4 in suction;
- leak detection: R-454B compatible refrigerant detector;
- manufacturer’s warranty: 10 years compressor, 10 years parts, 10 years labour.
Our work, step by step
AirGreen is a heating and cooling company in Montreal. Our refrigeration, ventilation and electrical work falls under RBQ licence 5645-9605-01. On this type of project, we proceed as follows:
- visit, furnace measurement, blower and panel check;
- installation of the coil in the plenum and sealing of the connections;
- outdoor unit on a pad or bracket, brazed piping, nitrogen test, vacuum;
- connection of the drain and the thermostat;
- commissioning, airflow adjustment and explanations at your home.
Common questions
Can I keep my current air conditioner? Generally not. This coil uses R-454B and requires the manufacturer’s outdoor unit. We install the complete set.
My furnace isn’t the same width. We measure it and, if needed, build an insulated transition on site.
Is the furnace still useful? Yes, with its blower, its filters and its role as backup heat.
To confirm before buying
- R-454B refrigerant requires an outdoor unit of the same type, installed at the same time;
- the published ratings apply to the certified pairing;
- the furnace must have the right width and a suitable blower, which we confirm at the visit.
LogisVert rebate
The matched Midea system appears on Hydro-Québec’s list of eligible heat pumps. The amount varies with the installation date and your situation. We check the official list at the quote and put the application together with you.
Take the next step
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Midea system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The MCPM4860CN10TH sits in the plenum of a furnace or air handler. Connected to the Midea MDV-V48WMN10T outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Midea MDV-V48WMN10T outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
MIDEASee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton Midea coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.