SENVILLE SENDC-24CO-B Evaporator A-Coil | 2 Tons

In stock

The Senville SENDC-24CO-B 2-ton R-454B cased coil sits on your furnace and, matched with the Senville SENDC-24HF-OG outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberSENDC-24CO-B

2 tons24,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 217447534
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSENDC-24CO-B
ManufacturerSenville
Size2 tons
Width17-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unitSENDC-24HF-OG

SENDC-24CO-B: the smallest cased coil in the Senville line, for homes that don't need more

In the Senville SENDC central series, the SENDC-24CO-B is the entry size: two tons, or a nominal 24,000 BTU/h, in an insulated cabinet 17-1/2 in wide. It sits on top of a furnace or a blower cabinet, takes R-454B refrigerant from the matched SENDC-24HF-OG outdoor unit and cools the air moving through your ductwork. With a heat pump outside, the same coil also provides heating. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

A small home, a small coil

Think of the row townhouse, the compact bungalow, the plex unit with its own furnace. These homes don't need a lot of cooling, and that is exactly where a two-ton size makes sense.

Equipment that is too big for the house shuts off as soon as the thermostat is satisfied, after only a few minutes. The air gets cold, but the moisture never had time to condense on the coil: the living room feels cool and yet clammy. A properly sized unit runs longer, dries the air and gives steadier comfort.

We don't pick a size at random for you. During the visit, we calculate the real load of the house. If the result calls for a larger size, we say so plainly: the decision follows the needs of the building, not what is sitting in our warehouse.

What the coil does, from July to January

The coil is the heat exchanger placed in the furnace's airstream. In summer, liquid refrigerant enters it, evaporates inside the tubes and absorbs heat from the air passing through. The moisture in that air condenses on the fins, drops into the pan and leaves through the drain.

In winter, if the outdoor unit is a heat pump, the cycle reverses: the heat captured outside is delivered to the air of the house through that same exchanger. The furnace keeps its blower, its filters and its role as backup heat. It takes over when the outdoor temperature falls below the threshold we set with you.

A specific match: the SENDC-24HF-OG

This coil is not an interchangeable part. The manufacturer specifies a single outdoor unit for it, the SENDC-24HF-OG. Together they form a certified system with AHRI number 217447534: cooling of 24,000 BTU/h, heating of 25,000 BTU/h at 47 °F, SEER2 16.0, HSPF2 9.5.

These ratings describe the system, not the coil alone. The coil has no efficiency rating of its own. When you compare two quotes, ask for the AHRI number of each: it is the only way to check that you are talking about the same system.

What Senville publishes about its matched outdoor units:

  • heating down to -30 °C in Hyper Heat mode, and down to -25 °C in regular mode;
  • cooling from 0 to 50 °C outdoors;
  • variable-speed compressor;
  • R-454B refrigerant, GWP 470;
  • SENDC-CO / SENDC-HF-OG matches certified ENERGY STAR cold climate, for the Canadian and U.S. markets;
  • compatible with a third-party 24 V thermostat, or the Senville wired Wi-Fi controller.

A-shape, insulated cabinet, TXV metering

The two faces of the coil slope toward each other and meet at the top, like the letter A. Air rises through the middle and passes through both faces, which suits upflow furnaces well. Because the unit arrives in its insulated cabinet, there is no housing to fabricate: installation goes faster and air leakage is better controlled.

The metering device is a TXV: a valve that doses the refrigerant sent to the coil according to the load at that moment. As for orientation, the manufacturer lists multi-position installation: upflow, downflow, horizontal right and left. A furnace lying on its side in an attic or a crawl space therefore remains an option.

SENDC-24CO-B specifications

  • type: cased evaporator coil, SENDC range;
  • nominal size: 2 tons (24,000 BTU/h);
  • refrigerant: R-454B;
  • dimensions (W × H × D): 17-1/2 × 18 × 21 in;
  • net weight: 42 lb;
  • condensate drain: 2 threaded 3/4 in female connections;
  • metering device: TXV;
  • leak detection: built-in R-454B refrigerant leak detector (15-year life); if a leak occurs, the indoor fan starts at high speed;
  • warranty: Senville SENDC central series (IG/OG units), 5 years parts, 10 years compressor; labour not covered; registration required; pressure test and vacuum by a licensed heating and cooling technician.

Choosing between the SENDC-24CO-B and its neighbours in the series

Four cased coils make up this series. Here is how to place them, based on what the manufacturer publishes:

  • SENDC-24CO-B (this model): 2 tons, 17-1/2 in wide, SENDC-24HF-OG outdoor unit;
  • SENDC-36CO-B: 3 tons, same 17-1/2 in width, SENDC-36HF-OG outdoor unit;
  • SENDC-36CO-C: 3 tons, 21 in wide, SENDC-36HF-OG outdoor unit;
  • SENDC-60CO-C: 4-5 tons, 21-5/8 in wide, SENDC-48HF-OG or SENDC-60HF-OG outdoor units.

All share R-454B and TXV metering. What really separates the models is therefore twofold: the capacity your home needs, and the width of your furnace. If the furnace measures 17-1/2 in, the choice is between this model and the SENDC-36CO-B, depending on the calculated load. If it is wider, the 21 in and larger models come into play. Otherwise, we fabricate an insulated transition on site.

Common questions

Can this coil provide heat? Yes, when it is matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.

Can I keep my current air conditioner? Generally not. The coil runs on R-454B and must be matched with the outdoor unit the manufacturer specifies. We install the complete system.

My furnace is a different width. What now? We measure it and, if needed, fabricate an insulated transition.

Is the furnace still useful? Yes. It keeps its blower and handles backup heat for the coldest days.

What a heat pump changes at home

An electric furnace converts each kilowatt-hour into an equal amount of heat. A heat pump moves heat from outside to inside: in mild temperatures, it delivers two to three times more than the electricity it uses. That efficiency drops as the cold deepens, which is why it makes sense to leave the furnace in place as backup.

In summer, a single outdoor unit replaces window air conditioners and distributes cool air through the existing ducts. One thermostat controls both seasons.

Why Senville for an existing furnace

Senville distributes wall-mounted, multi-zone and central heat pumps in Canada. In the SENDC series, the variable-speed outdoor unit, the cased coil and the 24 V thermostat are designed to work together, and each match is certified ENERGY STAR cold climate. It is a direct way to convert an electric furnace into a heat pump without redoing the air distribution.

Our installation in Greater Montreal

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and its outdoor unit, the installation includes:

  • measuring the furnace, and checking the blower and the electrical panel;
  • mounting the coil in the plenum, with a transition fabricated on site if needed, and sealing the duct connections;
  • installing the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test and vacuum;
  • connecting the condensate drain and the thermostat;
  • commissioning, airflow adjustment and an explanation of how everything works at home.

What to check before you buy

  • R-454B requires an outdoor unit with the same refrigerant, installed at the same time.
  • The published ratings apply only to the certified match.
  • The width of the furnace and the ability of its blower to deliver the system's airflow: we confirm both on site.

LogisVert incentive

The matched Senville system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list at the time of the quote and prepare the application with you.

A 2-ton Senville coil, installed by AirGreen

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Senville system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The SENDC-24CO-B sits in the plenum of a furnace or air handler. Connected to the Senville SENDC-24HF-OG outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Senville SENDC-24HF-OG outdoor unit
Certified systemMatched with the SENDC-24HF-OG, the system carries AHRI 217447534.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerSenville
ModelSENDC-24CO-B
TypeCased evaporator coil
LineSENDC
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Dimensions W × H × D17-1/2 × 18 × 21 in
Net weight42 lb
Matched outdoor unitSENDC-24HF-OG
System AHRI number217447534
System SEER2 / HSPF216.0 / 9.5
Model numberSENDC-24CO-B
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
SENVILLE
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Senville coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom