SENVILLE SENDC-36CO-B Evaporator A-Coil | 3 Tons
The Senville SENDC-36CO-B 3-ton R-454B cased coil sits on your furnace and, matched with the Senville SENDC-36HF-OG outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberSENDC-36CO-B
514 316-2973 · sales@airgreen.ca
Quick facts
The Senville SENDC-36CO-B coil: three tons for the narrow furnace of a bungalow or cottage
Picture the scene: a basement, a furnace against the wall, ducts rising toward every room and an old window air conditioner wheezing through each summer. The SENDC-36CO-B is cut out for that setting. It is a cased evaporator coil of 3 tons (36,000 BTU/h), 17-1/2 in wide, that runs on R-454B refrigerant and matches the Senville SENDC-36HF-OG outdoor unit. We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Where this model fits
The three-ton size suits a good share of the bungalows and cottages of Greater Montreal. The logic is simple: keep the furnace, keep the ducts, and add an exchanger in the plenum so that the system also cools, and heats if it is connected to a heat pump.
The furnace doesn't disappear. It keeps its blower, its filters and its role as backup heat for the harshest nights. This is what we call an "add-on" installation.
What happens in the plenum
When the outdoor unit works in cooling mode, the refrigerant reaches the coil as a liquid, boils at low temperature inside the tubes and absorbs heat from the house air. The water that forms on the fins drops into the pan and reaches the drain. The air comes out cooler and drier.
In heating mode, the direction of the cycle changes: the exchanger gives up to the air the heat recovered outside. The furnace steps in only below the outdoor temperature threshold that we set together.
The certified match
The manufacturer publishes a single match for this coil: the SENDC-36HF-OG outdoor unit, under AHRI number 217447535. The system figures are cooling of 36,000 BTU/h, heating of 38,000 BTU/h at 47 °F, SEER2 15.8, HSPF2 9.4.
Watch out for one misleading detail: these ratings belong to the whole system, never to the coil taken alone. If a quote doesn't cite an AHRI number, it is missing the piece that lets you compare it seriously with the others. That number is also the reference used for incentive programs.
On the matched outdoor units, Senville states:
- heating down to -30 °C in Hyper Heat mode (-25 °C in regular mode);
- cooling from 0 to 50 °C outdoors;
- variable-speed compressor;
- R-454B refrigerant, GWP 470;
- ENERGY STAR cold climate certification for all SENDC-CO / SENDC-HF-OG matches, Canada and the United States;
- compatible with a third-party 24 V thermostat, or the Senville wired Wi-Fi controller.
SENDC-36CO-B specifications
- type: cased A-coil;
- size: 3 tons (36,000 BTU/h);
- refrigerant: R-454B;
- dimensions (W × H × D): 17-1/2 × 23-1/2 × 21 in;
- net weight: 59.5 lb;
- condensate drain: 2 threaded 3/4 in female connections;
- metering device: TXV;
- orientations: multi-position, meaning upflow, downflow, horizontal right and left;
- leak detection: built-in R-454B refrigerant leak detector (15-year life); if a leak occurs, the indoor fan starts at high speed;
- manufacturer warranty: Senville SENDC central series (IG/OG units), 5 years parts, 10 years compressor; labour not covered; registration required; pressure test and vacuum by a licensed heating and cooling technician.
The SENDC-36CO-B next to its three neighbours
The series has four cased coils. To find your way around, let's look at what really sets them apart:
- SENDC-24CO-B: 2 tons, 17-1/2 in wide, SENDC-24HF-OG outdoor unit. Same width as this model, lower capacity;
- SENDC-36CO-B (this page): 3 tons, 17-1/2 in, SENDC-36HF-OG outdoor unit;
- SENDC-36CO-C: also 3 tons, but 21 in wide, with the same SENDC-36HF-OG outdoor unit;
- SENDC-60CO-C: 4-5 tons, 21-5/8 in, matched with the SENDC-48HF-OG or SENDC-60HF-OG units.
The choice between the three-ton -B and -C therefore doesn't come down to nominal cooling capacity: both show 36,000 BTU/h. It comes down to the width of the furnace. A narrow furnace calls for the -B model; a wider furnace, the -C. When the width matches neither, we fabricate an insulated transition right on site.
What stays common to the whole series: R-454B, TXV metering and the insulated cabinet. No surprises there.
Shape and installation
The A-coil has two sloped faces that meet at a point. The furnace air rises through the middle and passes through both faces, a common arrangement on upflow furnaces. Delivered in its insulated cabinet, it mounts directly on the furnace, with less sheet-metal work and better air sealing.
What your bill and your comfort gain
An electric furnace turns every kilowatt-hour consumed into the same amount of heat. A heat pump moves heat instead of making it: in mild weather, it supplies two to three times more than the energy it uses. Its efficiency decreases with the cold, which explains why the furnace stays as the relay.
In summer, a single outdoor unit serves every room through the ducts, with no window units to install and store. The humid heat of July becomes easier to live with because the air is dried as it passes through.
Senville in a few lines
The manufacturer distributes wall-mounted, multi-zone and central heat pumps in Canada. The SENDC series pairs a variable-speed outdoor unit, a cased coil and a 24 V thermostat, with an ENERGY STAR cold climate certification for each match.
Questions we often get
Can this coil provide heat? Yes, with a heat pump: cooling in summer, heating in winter. With a central air conditioner, it is cooling only.
Can my current air conditioner stay? Generally not. R-454B requires the outdoor unit the manufacturer specifies, so we install the complete system.
Is the furnace still used? Yes, for its blower and as backup heat below the threshold programmed with you.
Our installation in Greater Montreal
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and its outdoor unit, the installation includes:
- measuring the furnace, and checking the blower and the electrical panel;
- mounting the coil in the plenum, with a transition fabricated on site if needed, and sealing the duct connections;
- installing the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test and vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and an explanation of how everything works at home.
What to check before choosing
- R-454B refrigerant: the outdoor unit must be the same type and installed at the same time.
- The published ratings apply to the certified match, not to the coil alone.
- Furnace width and a blower able to deliver the system's airflow: checked during the visit.
LogisVert incentive
The matched Senville system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation. We consult the official list at the time of the quote and put the application together with you.
A 3-ton Senville coil, installed by AirGreen
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Senville system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The SENDC-36CO-B sits in the plenum of a furnace or air handler. Connected to the Senville SENDC-36HF-OG outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Senville SENDC-36HF-OG outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
SENVILLESee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Senville coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.