TRANE 5MXCA003AC3HCA Evaporator A-Coil | 1.5 to 3 Tons
The Trane 5MXCA003AC3HCA 1.5 to 3-ton R-454B cased coil sits on your furnace and, matched with a matching Trane outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model number5MXCA003AC3HCA
514 316-2973 · sales@airgreen.ca
Quick facts
5MXCA003AC3HCA: the narrowest of the Trane 5MXC series, made for compact furnaces
In a row house in Longueuil or a small bungalow in Laval, the furnace is often squeezed into a basement corner between a water heater and a concrete wall. The Trane 5MXCA003AC3HCA evaporator coil was designed for exactly that kind of space: at 14-1/2 in wide, it is the narrowest of the eight models we sell in this series. It covers a 1.5 to 3 ton size (36,000 BTU/h), runs on R-454B and comes in an insulated cabinet.
We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, always with the outdoor unit that matches it.
What an evaporator coil actually does
Picture a radiator running in reverse. Instead of heating the air, its aluminum and copper tubes cool it: the refrigerant arrives cold from the outdoor unit, evaporates inside the tubes and absorbs heat from the air that the furnace blower sends across it. Moisture in the air condenses on the fins, drips into a pan and runs off to the drain.
Without this component, an outdoor unit is useless: it is the link between the refrigerant and the air in your rooms.
A width of 14-1/2 in: the advantage and the constraint
The coil has to fit the top of the furnace. Too wide, and it overhangs; too narrow, and air leaks around the cabinet. At 14-1/2 in wide, the 5MXCA003AC3HCA suits the slimmest units. Its full dimensions are 14-1/2 × 20 × 21 in (width, height, depth) with a net weight of 44 lb: a package one technician can carry alone down a narrow basement staircase.
The constraint is that this width is not universal. Before any order, we measure your furnace. If the gap is small, we build an insulated transition on site rather than force a part that does not fit.
An air conditioning system, or a heat pump that keeps the furnace in reserve
Paired with a central air conditioner, this coil provides summer cooling. Paired with a heat pump, it does the opposite as well: in winter the cycle reverses and the refrigerant delivers the heat collected outdoors into your ducts. This is the "add-on" approach: the furnace stays in place, with its blower, filters and ductwork, and becomes your backup heat.
The temperature at which the furnace takes over is set with you at commissioning. That choice depends on your comfort, your insulation and your electricity bill.
Choosing between the 5MXCA003AC3HCA and its seven siblings
The whole series shares the same refrigerant (R-454B), the same TXV and the same type of cabinet. What changes is the width and the capacity range:
- 5MXCA003AC3HCA (this one): 14-1/2 in wide, 1.5 to 3 tons;
- 5MXCB004AC3HCA: 17-1/2 in, 1.5 to 3 tons;
- 5MXCB006AC3HCA: 17-1/2 in, 1.5 to 3.5 tons;
- 5MXCC005AC3HCA: 21 in, 1.5 to 3 tons;
- 5MXCC007AC3HCA: 21 in, 1.5 to 3.5 tons;
- 5MXCC009AC3HCA: 21 in, 3 to 5 tons;
- 5MXCD008AC3HCA: 24-1/2 in, 3 to 3.5 tons;
- 5MXCD010AC3HCA: 24-1/2 in, 3 to 5 tons.
A simple rule: start with the width of the furnace, then look at capacity. If your unit is narrow and your need falls between 1.5 and 3 tons, this model is the right candidate. If the furnace is wider, a wider coil will avoid the transition.
What Trane publishes about matching
The manufacturer's documents state that these coils are AHRI certified with Trane, American Standard, RunTru and Ameristar outdoor units (COR-PSD013B-EN). On the other hand, no ENERGY STAR match is published under the 5MXC prefix. We would rather say so plainly than let you believe otherwise.
The coil has no efficiency rating on its own. Seasonal ratings belong to the matched system, identified by an AHRI number. Before ordering, we check that number in the official directory, so the figures in your quote match those of your installation.
5MXCA003AC3HCA specifications
- type: cased evaporator coil, 5MXC series;
- nominal size: 1.5 to 3 tons (36,000 BTU/h);
- refrigerant: R-454B;
- expansion device: TXV;
- positions: multipoise (upflow, downflow, horizontal left or right);
- liquid connection 3/8 in, suction connection 3/4 in;
- condensate drain: 3/4 in NPT;
- dimensions: 14-1/2 × 20 × 21 in, net weight 44 lb;
- leak detection: the dimensional drawing (COR-PSD013B-EN) shows the location of a refrigerant sensor ("R454B Refrigerant Mitigation Sensor", MCB kit); the document does not describe its function.
Shape, expansion and positions
The A-coil forms a roof with two slopes: air rises through the centre of the furnace and passes through both faces. The TXV adjusts the refrigerant flow to the load, which steadies the discharge temperature. Because the unit is multipoise, it can be installed just as well on an upflow furnace as on a furnace lying on its side in an attic.
An insulated cabinet saves time and keeps the air better contained
This model arrives already housed in its insulated casing. In practical terms, nobody has to build a box around the coil out of sheet metal and insulation: we set it, connect it and seal it. In a space as tight as a row-house basement, every hour not spent cutting sheet metal is an hour less dust and noise for the family. A factory-built cabinet also limits air leaks between the furnace and the coil, and the insulation keeps the casing from beading with droplets when the air is humid in July.
The 3/8 in (liquid) and 3/4 in (suction) connections are the ones we braze to the outdoor unit's piping; the 3/4 in NPT drain takes a tube that runs to a drain or a condensate pump, depending on your basement layout.
What we do on installation day
- Measuring the furnace, checking the blower and the electrical panel.
- Installing the cabinet in the plenum, a custom transition if needed, sealing the duct joints.
- Setting the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum.
- Connecting the condensate drain and the thermostat.
- Commissioning, airflow adjustment, and a walk-through with the household.
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is carried out under our RBQ licence 5645-9605-01.
Three checks before you buy
- The coil and the outdoor unit must use the same refrigerant, R-454B, and be installed together.
- The furnace must measure about 14-1/2 in and deliver enough air: the blower is responsible for the system's airflow.
- The published ratings apply only to the certified match.
Frequently asked questions
Can I keep my old outdoor air conditioner? Generally not. The coil requires the unit specified by the manufacturer, with the same refrigerant.
My furnace is wider: what then? We measure it and, if needed, build an insulated transition on site.
What if I only have an air conditioner? Then the coil only cools; heating requires a heat pump.
Incentives
Financial assistance depends on the complete system, never on the coil alone. We check Hydro-Québec's official list against your installation date and tell you what applies.
A Trane 1.5 to 3 ton coil, installed by AirGreen
Book a free estimate visit: we measure the furnace, look at the electrical service and give you a written quote for the complete system. Financing lets you spread the cost of the project.
The heat pump coil for your furnace
The 5MXCA003AC3HCA sits in the plenum of a furnace or air handler. Connected to a matching Trane outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Trane outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 14-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
TRANESee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 1.5 to 3-ton Trane coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.