TRANE 5MXCC005AC3HCA Evaporator A-Coil | 1.5 to 3 Tons

In stock

The Trane 5MXCC005AC3HCA 1.5 to 3-ton R-454B cased coil sits on your furnace and, matched with a matching Trane outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model number5MXCC005AC3HCA

1.5 to 3 tons36,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model number5MXCC005AC3HCA
ManufacturerTrane
Size1.5 to 3 tons
Width21 in
RefrigerantR-454B
MeteringTXV

A 21 in furnace, a modest load: the Trane 5MXCC005AC3HCA

People often assume a big furnace automatically calls for a big air conditioner. That is not always true. Many homes in Longueuil, Laval or the North Shore were built with a wide furnace but have been well insulated since, and their cooling needs remain reasonable. For this specific case, the Trane 5MXCC005AC3HCA evaporator coil combines a 21 in wide cabinet with a 1.5 to 3 ton size (36,000 BTU/h). It runs on R-454B.

Who this model is for

Mostly homeowners whose furnace is 21 in wide but who do not need five tons of capacity. A concrete example: a renovated two-storey home in Montreal, windows replaced, attic insulated, whose original furnace stayed the same. The width dictates the cabinet; the cooling load dictates the capacity.

If you recognize your home in this description, this coil spares you from paying for a size the building would never use.

How it compares with the series

At 21 in, the series offers three models:

  • the 5MXCC005AC3HCA, the one you are looking at: 1.5 to 3 tons;
  • the 5MXCC007AC3HCA: 1.5 to 3.5 tons;
  • the 5MXCC009AC3HCA: 3 to 5 tons.

All three have the same TXV and the same refrigerant. The choice therefore comes down to capacity. The narrower 5MXCA003AC3HCA (14-1/2 in) and 5MXCB004AC3HCA (17-1/2 in) also cover 1.5 to 3 tons: they suit a slimmer furnace. At the other end, the 5MXCD008AC3HCA and the 5MXCD010AC3HCA are 24-1/2 in wide.

One piece of advice: do not choose a wider size "to be safe". The width follows the furnace, not the other way around.

What is a "cased" coil?

It is a coil delivered in an insulated casing, ready to sit on the furnace. This simplifies installation, limits air leaks and protects the sheet metal from condensation. This one measures 21 × 20 × 21 in (width, height, depth) and weighs 49 lb net. Its A shape means air passes through two sloped faces rather than just one, which gives a good exchange surface within a height of 20 in.

Matching, step by step

Step one: we measure your furnace and note its model. Step two: we choose a Trane outdoor unit of the same capacity and the same refrigerant. Step three: we check the pair's AHRI number in the official directory. Only then do we order. Trane lists coils AHRI certified with its outdoor units and those of American Standard, RunTru and Ameristar (COR-PSD013B-EN); no ENERGY STAR match is published under the 5MXC prefix.

Why so many precautions? Because the coil has no efficiency rating of its own. Whatever seasonal ratings you are promised only mean something for the certified pair.

And in winter?

With a heat pump, this coil takes part in the heating. It carries the heat collected outdoors into the home's air, through your ducts. The furnace stays in place, with its blower and filters; it steps in as backup when it is very cold, at the threshold we set with you. With a simple air conditioner, there is no heating: the coil only cools.

The small details that make a difference in a large furnace

A wide furnace usually has a wide plenum too, and that is where the coil finds its place. The larger the surface, the more evenly the air spreads across it: that is an advantage, provided the cabinet is well sealed. A poorly made joint lets air bypass the coil; it then returns lukewarm to the rooms and the house cools poorly. That is why we seal every duct connection and check airtightness before closing up.

Another detail: the slope of the drain. Condensate must flow by gravity, without sitting in the pan. If your basement has no floor drain nearby, we add a condensate pump, which is handled without difficulty.

Our service areas

We deliver and install in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Depending on the municipality, homes do not have the same age or the same furnace: a Montreal plex, a Laval semi-detached or a South Shore two-storey will each call for their own approach, and we adapt the installation accordingly.

What we do not promise

We will not quote you an efficiency rating for the coil alone, since it has none. Nor will we guarantee an incentive before we have checked the match and the installation date. What we do promise is a measurement taken at your home, a verified match and a clear written quote.

Technical data

  • model: 5MXCC005AC3HCA, 5MXC series;
  • size: 1.5 to 3 tons (36,000 BTU/h);
  • refrigerant: R-454B;
  • expansion device: TXV;
  • positions: multipoise (upflow, downflow, horizontal left or right);
  • liquid connection: 3/8 in; suction connection: 3/4 in;
  • condensate drain: 3/4 in NPT;
  • dimensions: 21 × 20 × 21 in;
  • net weight: 49 lb;
  • refrigerant sensor: location shown on the dimensional drawing (COR-PSD013B-EN, "R454B Refrigerant Mitigation Sensor", MCB kit), function not described in the document.

Why the TXV matters

A thermostatic expansion valve continuously adjusts the amount of refrigerant sent into the coil. When the house is hot, it lets more through; when the load drops, it reduces. The coil thus keeps a steady output without anyone having to touch it, which is useful on days when the temperature changes from morning to evening.

Our work on site

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the coil and sealing the duct connections, with a transition built on site if needed;
  • installing the outdoor unit, brazed piping, nitrogen leak test, vacuum;
  • connecting the drain and the thermostat;
  • commissioning, airflow adjustment and a demonstration.

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.

Five points to confirm before signing

  1. The refrigerant: R-454B for both components.
  2. The 21 in width, checked at the furnace.
  3. The airflow the blower can actually deliver.
  4. The home's load calculation, to validate the 1.5 to 3 ton range.
  5. The installation date, which affects incentive eligibility.

Quick answers

Is the furnace still used? Yes, as a backup heat source and for its blower.

Can I reuse my outdoor unit? Usually not: the refrigerant and the certified match rule it out.

Incentives

Hydro-Québec evaluates the complete system, not the coil alone. We check the official list against the installation date and tell you clearly what applies to your project.

A Trane 1.5 to 3 ton coil, installed by AirGreen

Ask for a free on-site estimate: we measure the furnace, check the electrical service and write up a quote for the complete system. Financing lets you spread the cost over time.

01 · What it is for

The heat pump coil for your furnace

The 5MXCC005AC3HCA sits in the plenum of a furnace or air handler. Connected to a matching Trane outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Trane outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerTrane
Model5MXCC005AC3HCA
TypeCased evaporator coil
Line5MXC
Nominal size1.5 to 3 tons (36,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D21 × 20 × 21 in
Net weight49 lb
Model number5MXCC005AC3HCA
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
TRANE
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5 to 3-ton Trane coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.