YORK CTM24A5ABS1 Evaporator A-Coil | 2 Tons
The York CTM24A5ABS1 2-ton R-454B cased coil sits on your furnace and, matched with a matching York outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTM24A5ABS1
514 316-2973 · sales@airgreen.ca
Quick facts
From the plenum to the thermostat: installing the CTM24A5ABS1, a 2-ton York coil for a narrow furnace
This model is easier to understand by following the work of a crew, from the first measurement to the first cool air. The York CTM24A5ABS1 evaporator coil delivers 2 tons, or 24,000 BTU/h, in a cabinet 14-1/2 in wide. It runs on R-454B refrigerant and pairs with a York outdoor unit of the same capacity. Townhouses, bungalows and plex units in Montreal, Laval, Longueuil, on the North Shore and on the South Shore are its usual territory.
Step one: the visit and the calculation
Before talking about equipment, we come to your home with a tape measure and a notebook. We note the width of the furnace, the condition of the blower, the electrical service and the possible route of the piping to the outside. We also assess the load of the house. If the number justifies 2 tons, the CTM24A5ABS1 comes into play. If it calls for more or less, we change models, because the decision follows your needs, not our inventory.
A system that is too big shuts off before it has dried the air: the room cools down but stays sticky. A properly sized unit runs longer and dries the air better.
Step two: checking the 14-1/2 in width
This is the measurement that decides everything. This coil lines up with a 14-1/2 in furnace. When the furnace is a different size, we build an insulated transition on site to connect the two without air leaks. If your furnace is clearly wider, the 17-1/2 in CTM24B5ABS1 is worth a look: it offers the same capacity.
Step three: setting the cabinet
The A-coil is delivered in an insulated cabinet. We slide it into the plenum, in the path of the warm air, and then we seal the duct joints. It weighs 40 lb net, and its dimensions of 14-1/2 × 23 in leave room to spare in most basements. York provides for multi-position installation: upflow, downflow, and horizontal left or right.
Step four: the outdoor unit and the piping
Outside, we install the unit on a pad or a bracket. The copper piping is brazed: 3/8 in for the liquid line, 3/4 in for the suction line. We then run a nitrogen leak test and pull a vacuum before releasing the refrigerant. For long distances, larger lines may be required, according to the outdoor unit's guide.
Step five: drain, thermostat and commissioning
The condensate flows from the pan to a drain that we connect. We wire the thermostat, adjust the nominal airflow of 800 CFM and show you how the whole system responds. This adjustment matters: York indicates about 350 to 450 CFM per ton of the outdoor unit and an external static pressure of 0.2 to 0.6 in. w.c.
What the coil says about itself
- type: cased evaporator coil, CTM range;
- capacity: 2 tons, 24,000 BTU/h;
- refrigerant: R-454B;
- metering device: TXV, which doses the refrigerant according to the load of the moment;
- width: 14-1/2 in, height 23 in;
- warranty: 10-year limited warranty on parts.
The leak sensor, already in place
R-454B belongs to the A2L family, which requires monitoring. A sensor is factory-mounted (code S) on the coil plate and wired to the RDS control board. Above 15% of the LFL, the compressor no longer receives a call and the indoor fan switches on. We verify it at commissioning.
Pairing with the right outdoor unit
The CTM24A5ABS1 is not sold with an efficiency rating of its own. SEER2, EER2 and HSPF2 describe a certified system: one coil, one outdoor unit, one AHRI number. That number is what lets you compare two quotes honestly. We confirm it in the AHRI directory before ordering.
York notably cites the HH8 heat pump (LX series), using R-454B, with a variable-speed compressor and ENERGY STAR certified for Canada and the United States. You do not need to remember the model numbers: we match them for you.
An example to fix ideas
Take a suburban bungalow on the South Shore, whose electric furnace is a few winters old and whose occupants sweat every July with two window air conditioners. The load calculation confirms that 2 tons are enough. We measure the furnace: 14-1/2 in wide, exactly the width of the cabinet. No transition to build, one plenum to open, one coil to slide into place. In a case like this, the CTM24A5ABS1 is the natural choice, and the installation stays simple.
Conversely, if the same furnace were wider, we would move to the CTM24B5ABS1 rather than force the fit. The unit does not change capacity; only the box changes size.
What you will feel at home
A well-sized system makes itself forgotten. The air moves gently, the temperature holds and the humidity drops. You will notice above all the absence of those cold spikes followed by clamminess that an oversized unit produces. In winter, with a heat pump, the heat arrives through the usual vents, with no baseboards added and no new units in the rooms.
What happens to the furnace?
It stays. Its blower pushes air through your ducts, its filters keep working and it provides backup when the cold becomes too sharp for the heat pump. We set with you the outdoor temperature at which it takes over. In summer, the same coil replaces the window air conditioners: one unit outside, cool air in every room.
Choosing between this model and its neighbours
- CTM18A5AAS1: 1.5 tons, 14-1/2 in wide.
- CTM24A5ABS1: 2 tons, 14-1/2 in wide (this page).
- CTM24B5ABS1: 2 tons, 17-1/2 in wide.
All three use R-454B, with a TXV and a cabinet. Two questions are enough: how many tons does your house call for, and how wide is your furnace? The CTM18A5AAS1 suits the smallest volumes. The CTM24A5ABS1 covers the 2-ton size when the furnace is narrow. The CTM24B5ABS1 offers the same capacity in 17-1/2 in.
To check before signing
- R-454B refrigerant requires a compatible outdoor unit, installed at the same time as the coil.
- The advertised ratings belong to the certified match.
- The furnace blower must be able to deliver the system's airflow; we check it on site.
Maintenance and follow-up after installation
After commissioning, there is little left for you to do: keep the filter clean, keep the vents clear and watch that the drain runs freely. If an adjustment needs to be revisited after the first season, a single call is enough, since we installed the whole system. We also keep the match references on file, which makes any future verification easier.
Hydro-Québec incentives
The coil alone opens no rights: it is the complete system that counts. We consult the official list according to the installation date and tell you what applies, at the time of the quote.
Who we are, and how to move forward
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. We work under RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work.
Request a free on-site estimate. We measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing lets you spread out the cost of the project.
The heat pump coil for your furnace
The CTM24A5ABS1 sits in the plenum of a furnace or air handler. Connected to a matching York outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching York outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 14-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.