YORK CTM24B5ABS1 Evaporator A-Coil | 2 Tons

In stock

The York CTM24B5ABS1 2-ton R-454B cased coil sits on your furnace and, matched with a matching York outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCTM24B5ABS1

2 tons24,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCTM24B5ABS1
ManufacturerYork
Size2 tons
Width17-1/2 in
RefrigerantR-454B
MeteringTXV

CTM24B5ABS1: 2 tons in a cabinet 17-1/2 in wide, for the furnace that does not fit the mould

Not every furnace has the same width. When yours goes beyond the usual size, the York CTM24B5ABS1 evaporator coil spares you a lot of acrobatics. This cased A-coil from the York CTM range delivers 2 tons (24,000 BTU/h) and measures 17-1/2 in wide. It runs on R-454B. AirGreen installs it in the Montreal, Laval, Longueuil, North Shore and South Shore areas.

Why width matters so much

The coil sits on top of the furnace. If the cabinet is narrower than the plenum, the air finds ways to leak; if it is wider, it overhangs. That is why it pays to choose a width close to yours. Here, it is 17-1/2 in by 23 in high. When a gap remains anyway, we build an insulated transition right at your home.

What 2 tons means for your home

The 2-ton size is found in townhouses, compact bungalows and some plex units. We offer it only after calculating the load. A unit stronger than necessary starts and stops constantly, leaves moisture in place and wears out its components. It is better to have a size matched to your needs than a unit chosen out of habit.

A sample house

Imagine a townhouse in Longueuil whose furnace, wider than average, takes up almost the whole basement alcove. The load calculation points to 2 tons. The narrower CTM24A5ABS1 would require a transition to cover the opening. The CTM24B5ABS1, at 17-1/2 in, fits the plenum better. Fewer custom parts, fewer joints to seal, and a cleaner installation.

What you will feel day to day

When the capacity matches the load, the system runs for a long time at low speed. The air is more even from room to room and the summer humidity drops noticeably. With a heat pump, winter brings the same gentle heat through the existing vents, and the furnace waits its turn for the deep cold.

Weight, a reassuring detail

Despite its width, the CTM24B5ABS1 weighs 38 lb net, which is less than its narrower neighbour of the same capacity. For the crew carrying the unit down a basement staircase, this is noticeable.

The coil up close

  • model: CTM24B5ABS1, cased coil;
  • nominal capacity: 2 tons, 24,000 BTU/h;
  • refrigerant: R-454B;
  • dimensions: 17-1/2 × 23 in;
  • metering device: TXV;
  • connections: 3/8 in liquid, 3/4 in suction;
  • nominal airflow: 800 CFM;
  • positions: upflow, downflow, horizontal left or right;
  • warranty: 10-year limited warranty on parts.

The role of the TXV

The TXV is a thermostatic expansion valve. It lets into the coil just the amount of refrigerant that the warm air needs. In a heat wave, it opens wider; in the shoulder seasons, it closes down. The coil stays well fed without flooding the compressor.

Built-in leak detection

R-454B is an A2L refrigerant, which requires a detector. The one on the CTM24B5ABS1 is factory-installed (code S), on the coil plate, and connected to the RDS control board. When the concentration passes 15% of the LFL, the call for the compressor stops and the indoor fan starts up, to dilute the air.

The outdoor unit that goes with it

This coil pairs with a York outdoor unit of the same capacity and the same refrigerant. Among the models published by York is the HH8 heat pump (LX series) using R-454B, variable-speed, ENERGY STAR certified for Canada and the United States. A heat pump of this type can heat in winter through the same ducts that cool in summer; with a central air conditioner, the coil only cools.

The efficiency ratings (SEER2, EER2, HSPF2) attach not to the coil alone but to the certified combination, identified by an AHRI number. We look up that number before placing the order so that the figures promised are the ones you will get.

Placing this coil among its siblings

  • CTM18A5AAS1: 1.5 tons, 14-1/2 in. For small volumes.
  • CTM24A5ABS1: 2 tons, 14-1/2 in. Same capacity as this one, but for a narrower furnace.
  • CTM24B5ABS1: 2 tons, 17-1/2 in. This page.

All three run on R-454B, with a TXV and a cabinet. The only thing separating the two 2-ton models is width: 14-1/2 in versus 17-1/2 in. Measure your furnace, or let us do it, and the answer becomes obvious.

What we do on installation day

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. Our crew:

  • measures the furnace and checks the blower and the electrical panel;
  • sets the coil in the plenum and seals the duct connections;
  • installs the outdoor unit, brazes the piping, runs the nitrogen test and pulls the vacuum;
  • connects the condensate drain and the thermostat;
  • sets the airflow, which sits around 350 to 450 CFM per ton of the outdoor unit, and explains the whole system to you.

Questions people ask us

Can I keep my current air conditioner? Generally not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.

Is the furnace still useful? Yes. It keeps its blower and provides backup when it is too cold outside for the heat pump alone.

Checkpoints before buying

  • The same refrigerant on both sides, installed at the same time.
  • Ratings valid for the certified match only.
  • A furnace of the right width, with a blower able to deliver the system's airflow.

A word on noise and air

A cabinet better fitted to the furnace reduces whistling at the joints, and a properly set blower avoids unpleasant drafts at the vents. These are details that appear on no spec sheet, but that you will notice from the first week, especially if your living rooms are close to the furnace.

Incentives

Hydro-Québec programs apply to the complete system, never to the coil alone. We check your match against the official list according to the installation date and explain what applies.

Why use an installer rather than going it alone

A coil is only one part of the system. The match, the refrigerant charge, the vacuum, the airflow and the drain decide the lifespan of the whole. By entrusting everything to a single crew, you avoid the back-and-forth between the seller, the electrician and the refrigeration technician, and you know whom to call back if an adjustment needs to be revisited after the first season.

We also go over the basics with you: where the filter is, how to read the thermostat, which noise is normal and which one deserves a call.

Let us take the measurements

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CTM24B5ABS1 sits in the plenum of a furnace or air handler. Connected to a matching York outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching York outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
ModelCTM24B5ABS1
TypeCased evaporator coil
LineCTM
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Airflow800 CFM
Dimensions W × H × D17-1/2 × 23 in
Net weight38 lb
Model numberCTM24B5ABS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
YORK
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton York coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.