Central Heat Pump ADD-ON ARCOAIRE N4H5S Performance | 4 Tons - 48,000 BTU (Coil EVD4X 24.5 in.) - R410A
Four tons on the furnace, provided the assessment confirms it
The ADD-ON system adds a heat pump to an existing electric furnace: a coil is installed on the furnace and the outdoor unit heats and cools through the same ducts. The furnace's electric elements are only used as backup. The Central Heat Pump ADD-ON ARCOAIRE N4H5S Performance | 4 Tons - 48,000 BTU (Coil EVD4X 24.5 in.) - R410A pairs the N4H5S48AKAAA outdoor unit with the EVD4X48M24A coil.
At this size, the most common mistake is not a lack of capacity but too much of it. A 4-ton system suits a large house; installed in a house that does not need that much, it cools in bursts and leaves the air humid. This page explains how we decide whether this size is the right one for you.
Which homes suit the 4-ton size
The 4-ton size is often found in a large two-level house with a finished basement, a heavily glazed house facing south or west, or an extended house whose duct system now serves more rooms than it did originally, in Laval as on the South Shore. These examples are only a guide. A large, recent, well-insulated house may do with a smaller size, while a more modest house that is very sunny and leaky may need more.
Why we size on cooling
In an ADD-ON, the electric furnace stays in place, and its heating elements cover the coldest days. The heat pump therefore does not have to cover the winter peak on its own, and we size it on the house's cooling load. This choice protects what matters in summer: cycles long enough to remove humidity, a stable temperature and a compressor that does not start over and over.
Conversely, choosing the size based on heating would often push toward a unit that is too big for summer. The furnace's electric elements are there precisely to avoid that compromise.
What the on-site assessment measures
The on-site assessment is done room by room. During the visit, we record:
- the area and orientation of the windows, their type and the shading they get;
- the insulation of the walls, attic and basement, as it can be observed or documented;
- the overall airtightness of the house and known sources of air leakage;
- internal heat gains: kitchen, appliances, number of occupants;
- the layout of the rooms and how the duct system serves them.
The result gives a cooling load and a heat loss for each room, then for the whole house. That is the basis on which we recommend a size, not the size of the old unit.
When the house falls between two sizes
Sometimes the assessment places the house between two sizes. We then look at two things. First, the capacity of the duct system and the furnace blower: a larger size makes no sense if the ducts cannot carry the air it requires. Second, the house's summer profile: a humid house, or one that gets a lot of afternoon sun, does not behave like a shaded one. We present both options and the reason for our recommendation.
The Performance series and the 24.5 in. coil
The N4H5S48AKAAA unit belongs to Arcoaire's Performance series. At this size, the EVD4X48M24A coil is shared by several series of outdoor units; what sets them apart is the outdoor unit, and the ratings of each pairing are confirmed before the quote.
The coil is a 24.5 in. format, designed for the wide cabinets often found on high-capacity furnaces. If your furnace's width differs, a sealed sheet-metal transition joins the two.
System ratings
The pairing of the N4H5S48AKAAA outdoor unit and the EVD4X48M24A coil is not listed with SEER2 ratings in the AHRI certification directory. We confirm the ratings of the complete system before the quote; they also determine grant eligibility.
We confirm them for the size chosen after the on-site assessment: if your house calls for a neighbouring size, those are the ratings of that pairing you receive in writing. This page therefore shows no efficiency rating.
The manufacturer designs the EVD4X coil for air conditioning ("AC applications only"). For a heat pump, AirGreen confirms at the visit a coil approved for heating and the pairing’s AHRI rating, before the quote.
Winter, in two steps
In cool weather, the heat pump heats alone. When the cold deepens and it can no longer hold the set point, the thermostat brings in the furnace's electric elements as auxiliary heat. The auxiliary heat threshold is set at commissioning based on the estimated heat loss and your preferences. During the outdoor unit's defrost, a plume of vapour forms and the furnace's elements may come on briefly so that the air at the registers stays warm.
The heat pump's air is less hot than the air from the electric elements and its cycles are longer; heat is spread more evenly through a large house.
Dehumidification, one more reason to size correctly
In summer, the coil cools the air and removes humidity, which drains through the condensate line. This dehumidification happens mostly during long cycles: at the start of a cycle, the coil must first cool down before it condenses water. An oversized unit reaches the set point before it has dried the air, and the house stays cool but clammy. A properly sized unit runs longer and leaves the house drier, which you clearly feel during heat waves in Montreal.
LogisVert
This pairing does not carry an amount on Hydro-Québec's LogisVert list of October 19, 2026. If the grant matters for your project, we will point you to an eligible pairing of comparable size.
Installation on the existing furnace
The coil sits on the furnace's air outlet, and a compatible thermostat decides when the heat pump heats alone and when the electric furnace takes over. We check the condition of the furnace, the airflow of its blower and the duct sizes before the quote. The outdoor unit goes on a stand, above the snow line, on a dedicated circuit.
Checks specific to a large size
A 4-ton system asks more of the house than a small one. Before the quote, we check that the furnace blower can deliver the airflow the coil requires, that the main ducts and the returns can carry it, and that the electrical panel has the capacity needed for the outdoor unit's dedicated circuit, on top of the electric furnace that stays in service for backup.
The outdoor unit, bulkier than a small size, goes on a sturdy stand above the snow line, out of roof drip and away from bedroom windows. The insulated refrigerant line set is brazed under nitrogen, pressure-tested and evacuated, then the R-410A charge is adjusted at commissioning, along with the airflow and the thermostat's auxiliary heat threshold.
Maintenance
Replace the system filter according to its format, keep the outdoor unit clear of snow and leaves, and plan annual HVAC maintenance of the coil, condensate drain and electrical connections. In winter, white vapour during defrost is normal.
At this size, the coil handles a large volume of air. A clean filter and a clean coil keep the capacity the assessment planned for; a clogged filter, on the other hand, gives up part of the benefit of careful sizing. The electric furnace keeps its usual maintenance: blower, heating elements and connections.
AirGreen, for the life of the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.
Request your free estimate for the Central Heat Pump ADD-ON ARCOAIRE N4H5S Performance | 4 Tons - 48,000 BTU (Coil EVD4X 24.5 in.) - R410A. We assess the home room by room and confirm the right size and your grant eligibility before signing.
Available while supplies last.
Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.