An ADD-ON central heat pump designed to improve an existing system without replacing it
At AirGreen, we work every day with homeowners who want to optimize their existing HVAC system without replacing the whole central system. The CANAIR 4CDH R-454B "ADD-ON" Central Heat Pump | 2 tons was designed precisely for this kind of project. It works with an existing electric furnace or central system, adding efficient heating and cooling capacity suited to Quebec's climate.
In Montreal, Laval, Longueuil, on the North Shore and the South Shore, much of the housing stock still relies on central systems that work but use a lot of energy. In these situations, a well-designed ADD-ON solution raises the building's overall efficiency, lowers energy costs and improves comfort, without changing the existing infrastructure.
A design truly suited to Quebec's harsh winters
Heating down to -30°C, backed by NEEP figures
The CANAIR 4CDH R-454B is ENERGY STAR® cold climate certified. For the 2-ton (24,000 BTU) version, NEEP data for this system (AHRI 216621487) show:
Rated capacity: 24,000 BTU
Heating at -8°C: 19,700 BTU/h (COP 2.66)
Heating at -15°C: 21,000 BTU/h (COP 1.8)
Heating at -30°C: up to 12,100 BTU/h (COP 1.31)
In practice, the heat pump keeps heating when temperatures drop well below freezing, which reduces the use of the furnace's electric element. In deep cold, that element covers the share of heat that is missing. The inverter compressor keeps the indoor temperature stable, without sudden swings or excessive heating cycles.
Consistent efficiency all year round
The energy performance of this ADD-ON central heat pump is particularly attractive for Quebec homes:
SEER2: 16.0 and EER2: 10.0, for efficient cooling during increasingly hot summers
HSPF2 (region IV): 9.5, for sustained heating efficiency
COP of 2.66 at -8°C (NEEP), a key indicator of winter performance
These values translate into a reduction in annual electricity use compared with electric heating alone, especially where the heating season is long.
R-454B refrigerant: a responsible, forward-looking choice
The CANAIR 4CDH Central Heat Pump uses R-454B refrigerant, an A2L fluid with a global warming potential of 466, compared with 2,088 for the R-410A of earlier generations. This choice meets current environmental requirements and the expectations of clients who want to limit their carbon footprint.
An ADD-ON solution designed for existing central systems
Direct integration with no major rebuild
The main advantage of an ADD-ON central heat pump is how it fits into an existing system. The CANAIR 4CDH R-454B 2T pairs the 4CDH2024C21 outdoor unit with a CEB-24MX1421 cased coil (14.5 × 21 × 18 in.), set on the furnace and connected to the existing ductwork.
At AirGreen, we install this configuration when:
the ducts are in good condition and properly sized,
the air distribution is balanced,
but the main heating system is costly to run or performs poorly.
In these cases, the ADD-ON is a targeted, rational upgrade: no demolition, no invasive work and no loss of comfort during the transition.
Compact format and installation flexibility
The side-discharge outdoor unit is slimmer than traditional top-discharge models. This makes installation easier in tight urban settings, such as some narrow Montreal backyards, or wherever space around the building is limited.
The cased coil installs vertically or horizontally, so it can be fitted precisely to the existing mechanical room. This is a real advantage in older homes, where technical space is often tight.
Quiet, stable, everyday comfort
Discreet operation, indoors and out
Acoustic comfort is often underestimated when choosing a central heat pump. The CANAIR 4CDH 2T has an outdoor sound level of about 60 dB(A), which keeps it discreet even in dense residential neighbourhoods.
Indoors, the existing furnace blower moves the air across the coil. AirGreen checks and adjusts that airflow at start-up, for an even temperature in every room served by the ductwork. The inverter compressor modulates its output continuously, with no abrupt starts.
Refrigerant safety
Like every R-454B (A2L) system, this ADD-ON central heat pump includes refrigerant leak detection, connected and checked during installation. A central system runs many hours every year: careful commissioning helps extend the equipment's life and reduce the risk of costly breakdowns.
Backup heat stays with your furnace
With an ADD-ON system, the electric backup heat is the existing furnace's. The heat pump supplies most of the heat for most of the winter, and the furnace tops up during deep cold.
During the assessment, AirGreen also checks the capacity of the existing electrical panel, to avoid surprises.
Hydro-Québec LogisVert aid and the value of the project
This combination (AHRI 216621487) is on Hydro-Québec's LogisVert list of October 27, 2026, with an indicative amount of $2,364. Only Hydro-Québec confirms the aid granted. In our approach, this aid is never looked at on its own. We include it in an overall analysis covering:
the total cost of the HVAC installation,
the projected energy savings,
the system's durability,
and the client's real return on investment.
AirGreen expertise at the heart of every installation
Installing an ADD-ON central heat pump takes specific expertise. It is not just a matter of connecting an outdoor unit to an existing system. Success depends on several factors:
choosing the tonnage for the heating needs,
assessing the ductwork,
balancing the airflow,
and setting the furnace's backup heat correctly.
The most common mistakes are poor integration with the existing system or a poor initial setup. Our method aims to remove these risks from the assessment stage. Our refrigeration technicians work under AirGreen's RBQ licence 5645-9605-01. To see installations completed by our teams, visit our Our projects page.
A coherent, durable and scalable central solution
The CANAIR 4CDH R-454B "ADD-ON" Central Heat Pump | 2T is for homeowners who want to upgrade their HVAC system thoughtfully. It combines energy efficiency, compatibility with existing systems, reliable cold-climate operation and compliance with current standards.
Take the next step with AirGreen
For a detailed assessment, a clear estimate or advice suited to your building, contact AirGreen directly at 514-316-2973 or sales@airgreen.ca. Our teams support you at every step, from the first assessment to the final installation, throughout Montreal, Laval, Longueuil, the North Shore and the South Shore.
Warranty: 10 years on the compressor, 10 years on parts and 6 years on labour, directly from the distributor.