An ADD-ON central heat pump designed for Quebec's real-world conditions
At AirGreen, we have been installing central heat pump systems for over 15 years in a wide range of settings: single-family homes in Montreal, duplexes and triplexes in Laval, multi-unit buildings in Longueuil, light commercial buildings on the South Shore and isolated properties on the North Shore. This field experience taught us one essential thing: a good HVAC system does not just perform on paper, it has to be suited to the building's climate, architecture and electrical reality.
The CANAIR 4CDH R-454B "ADD-ON" Central Heat Pump | 3 tons (36,000 BTU) follows exactly this logic. It is a high-efficiency central system that heats down to -30°C while fitting into an existing installation. Its ADD-ON approach clearly improves a building's energy performance without a complete overhaul of the HVAC system.
In practice, this model suits homeowners who want to modernize their heating as well as property managers looking for a reliable, durable solution with controlled running costs.
Understanding the ADD-ON approach: a realistic, effective HVAC strategy
Smart integration with the existing system
An ADD-ON central heat pump is not a simple replacement. It becomes the main source of heating and cooling, working alongside an existing electric furnace that stays as backup. This configuration lets you:
use the heat pump as the main source for most of the year;
limit the use of electric elements to periods of extreme cold;
keep the ductwork and HVAC layout already in place;
reduce structural work and disruption to occupants.
In Montreal and dense urban areas, this approach is often the smartest, both technically and financially.
A particularly relevant solution for existing buildings
In many existing buildings, a complete conversion to a new central system is not possible without major changes. The CANAIR 4CDH ADD-ON model then improves energy performance while respecting the building's constraints, especially electrical capacity and mechanical space.
Heating performance suited to Quebec winters
Heating down to -30°C, backed by NEEP figures
According to NEEP data for this combination (AHRI 216621493), the 3-ton (36,000 BTU) CANAIR 4CDH delivers:
29,200 BTU/h at -8°C (COP 2.5);
36,000 BTU/h at -15°C (COP 1.9);
up to 28,600 BTU/h at -30°C (COP 1.61);
steady efficiency thanks to variable-speed inverter technology, with a smooth hand-off to the furnace's backup heat when needed.
Predictable, controlled behaviour
The CANAIR 4CDH behaves predictably as the outdoor temperature changes. This makes it easier to set the switch-over points between the heat pump and the backup heat precisely, which is crucial to optimizing overall energy use.
Efficient, balanced central air conditioning
In cooling mode, the nominal capacity of 36,000 BTU meets the needs of medium to large homes and some multi-unit buildings. Thanks to inverter modulation:
the temperature stays even from room to room;
abrupt swings are limited;
humidity is better controlled, especially during heat waves.
A mechanical design built for real installations
Side-discharge outdoor unit
The side-discharge format of the 4CDH2036C21 outdoor unit is a real advantage during installation:
easier placement in narrow backyards;
better use of space on flat roofs;
installation possible near walls or fences, within the required clearances.
For AirGreen crews, this design means a faster, cleaner installation better suited to urban settings.
A cased coil that works with your furnace
The CEB-36MX2121 cased coil (21 × 21 × 24 in.) is installed on the existing furnace:
vertical or horizontal configuration;
easy access to the coil for maintenance;
air moved by the existing furnace blower, with airflow checked and adjusted by AirGreen to suit the duct pressure;
3/8 in. and 3/4 in. refrigerant line connections.
This versatility makes it easier to fit the system into existing mechanical rooms without major rebuilding.
R-454B refrigerant: a responsible technical choice
Choosing R-454B refrigerant makes sense from a regulatory, environmental and technical standpoint:
global warming potential of 466, compared with 2,088 for R-410A;
A2L classification, with the leak detection required for these refrigerants;
compliance with current HVAC requirements.
Refrigerant leak detection is connected and checked during installation, which is especially important in multi-unit buildings.
Measurable efficiency and LogisVert aid
Performance ratings
For this 36,000 BTU combination (AHRI 216621493):
SEER2 of 15.8 and EER2 of 10.7, for efficient cooling all season;
HSPF2 (region IV) of 9.4, for solid heating efficiency;
ENERGY STAR® cold climate certification, required for LogisVert eligibility.
Hydro-Québec LogisVert aid
This combination (AHRI 216621493) is on Hydro-Québec's LogisVert list of October 27, 2026, with an indicative amount of $3,504. Only Hydro-Québec confirms the aid granted. At AirGreen, we support our clients in Montreal, Laval, Longueuil, the North Shore and the South Shore with:
an upfront technical check;
the documents needed for the application;
support until the application is filed.
Everyday comfort and reliability
automatic defrost of the outdoor unit;
inverter compressor, which modulates its output instead of constantly starting and stopping;
discreet operation, indoors and out (about 62.5 dB(A) outdoors).
These elements, often overlooked at purchase, play a decisive role in the system's durability and long-term satisfaction.
Warranty and a long-term view
The system is covered by:
10 years on the compressor;
10 years on parts;
6 years on labour, directly from the distributor, with the option of an extended labour warranty.
For owners and property managers, this coverage is a key factor in budget planning and risk management.
Why trust AirGreen with the installation
Installing an ADD-ON central heat pump takes much more than a simple hookup. It requires:
an on-site assessment of heating needs;
a clear understanding of how the heat pump and the existing furnace interact;
precise airflow balancing;
settings suited to the local climate and how the building is actually used.
At AirGreen, every installation is done by experienced refrigeration technicians, under AirGreen's RBQ licence 5645-9605-01, with a rigorous, transparent method. We deliberately avoid common mistakes such as:
needless oversizing;
a poorly set blower airflow;
poor coordination between the heat pump and the backup heat.
To see installations completed by our teams, visit our Our projects page.
Conclusion
The CANAIR 4CDH R-454B "ADD-ON" Central Heat Pump | 36,000 BTU is a structured, reliable and coherent solution for Quebec buildings that want better energy efficiency without compromising comfort.
For a personalized analysis, a detailed quote or to check LogisVert eligibility in Montreal, Laval, Longueuil, the North Shore or the South Shore, contact AirGreen directly at 514-316-2973 or sales@airgreen.ca. Our team will take the time to assess your building and offer a solution suited to your situation.
Warranty: 10 years on the compressor, 10 years on parts and 6 years on labour, directly from the distributor.