GENERAL AIRSTAGE INFINITE COMFORT 48LMAH1M Central Heat Pump of 4 Tons in Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: AOUH48LMAH1
48,000BTU/h · nominal capacity
−26 °Cheats down to
51,000BTU/h at −15 °C
Optional Wi-FiR-410A12-yr compressor, 12-yr parts
Talk to a technician · 514 316-2973
Outdoor unitAOUH48LMAH1
Air handler (indoor) AMUG48LMAS
AHRI207657378

GENERAL AIRSTAGE INFINITE COMFORT 48LMAH1M Central Heat Pump, 48,000 BTU: heating a large house from the basement

Fujitsu AIRSTAGE or GENERAL AIRSTAGE, what arrives in your basement is identical: the AMUG48LMAS multi-position air handler and the AOUH48LMAH1 outdoor unit, combined in the 48LMAH1M system. Model numbers, manufacturer’s spec sheet, warranty: nothing differs. On January 1, 2026, Fujitsu General Limited took the name GENERAL Inc., and that is the only change.

This system is designed for the large house: two full floors, a basement, rooms far apart from one another, and owners who want the heat pump to carry the heating as far into winter as possible. The manufacturer lists the AOUH48LMAH1 among its extra-low-temperature heating models; in the basement, the AMUG48LMAS takes the furnace’s place and feeds the entire ductwork.

To be said before anything else: according to the spec sheet, this system does not carry ENERGY STAR certification, and LogisVert does not count it among its listed units.

GENERAL or Fujitsu AIRSTAGE: the same machine

Behind the new name, there is a transaction. In August 2025, Fujitsu General Limited changed hands: Paloma Rheem Holdings, Rheem’s parent company since 1988, acquired it, and the name GENERAL Inc. has replaced the old one since January 1, 2026. Kawasaki, Japan, remains home base for the head office and R&D centre, while nothing changes in the factories, the model numbers or the warranty program of AIRSTAGE products. GENERAL is not a brand invented for the occasion, either, since the manufacturer has used it since 1946.

The Fujitsu brand is being withdrawn gradually; in the meantime, the same machine carries one name or the other depending on the box. We publish both pages so you can check for yourself that nothing sets them apart. Rheem Canada has managed sales in Canada since February 2026, our orders still go through Groupe Master, and we install these systems as an AIRSTAGE Elite Plus installer.

SpecificationGENERAL AIRSTAGEFujitsu AIRSTAGE
Indoor unitAMUG48LMASAMUG48LMAS
Outdoor unitAOUH48LMAH1AOUH48LMAH1
AHRI certificate207657378207657378
Nominal capacity48,000 BTU48,000 BTU
RefrigerantR-410AR-410A
Power supply208/230 V208/230 V
SEER216.616.6
HSPF210.010.0
EER28.88.8
Heating capacity at −8 °C34,400 BTU34,400 BTU
Heating capacity at −15 °C51,000 BTU51,000 BTU
COP at −15 °C1.921.92
Heating down to−26 °C−26 °C
ENERGY STARNoNo
Indoor unit dimensions (W × D × H, in)21 x 21.69 x 5721 x 21.69 x 57
Outdoor unit dimensions (W × D × H, in)38.19 x 14.56 x 52.538.19 x 14.56 x 52.5
Indoor sound level (min / max)29 / 47 dB(A)29 / 47 dB(A)
Outdoor sound level54.0 dB(A)54.0 dB(A)
Airflow1,640 CFM1,640 CFM
Wi-FiOptionalOptional
LogisVert grant (Hydro-Québec, list of October 27, 2026)Not listedNot listed
Warranty (compressor · parts · labour, years)12 · 12 · 612 · 12 · 6
ManufacturerGENERAL Inc. (Kawasaki, Japan)GENERAL Inc. (Kawasaki, Japan)
Product pageThis pageFujitsu AIRSTAGE INFINITE 48,000 BTU

Compare at your leisure with the Fujitsu page for the 48LMAH1M, with identical values.

A central heat pump for a large house starts with a well-placed unit. In the basement, the AMUG48LMAS stands upright, in upflow, ideally near the centre of the ductwork so that the runs to distant rooms stay reasonable. The house air enters through the return air, crosses the all-aluminum coil, then leaves through the plenum toward the grilles on both floors.

Plan for a cabinet 57 in. high and 21 in. wide, plus the plenum above it and the return-air connection. The basement’s clear height is therefore measured at the visit, as is the service space: the manufacturer requires 21 in. of free space in front of the unit and a minimum clearance on its three other sides. When an old furnace already occupies the ideal spot, we generally reuse that location and its connections.

The basement is not always the right answer, and the unit allows for that. Truly multi-position, it can also blow in downflow from an upper floor or lie horizontally in a service space; there is no kit to buy for these setups, since the downflow and horizontal-right kits ship free with the unit. In a large house, that choice sometimes keeps a finished basement intact.

A large house needs a lot of air, and that air has to travel. Airflow can reach 1,640 CFM, with up to 1.0 in. WC of allowable static pressure, a high value, and a fan motor run by adaptive control. The ductwork still has to keep up: a return that is too small or ducts crushed over years of renovations will hold back any unit. We inspect them before pricing anything.

AHRI certificate 207657378 gives the system an HSPF2 of 10.0, a SEER2 of 16.6 and an EER2 of 8.8. Its nominal capacities, according to the manufacturer: 51,000 BTU/h in heating, 45,500 BTU/h in cooling. At −8 °C, the published heating capacity is 34,400 BTU; at −15 °C, it is 51,000 BTU, for a COP of 1.92. These are different test points, to be read separately, and the figure of 51,000 therefore appears for two distinct measurements: we report it as is. The heating range extends down to −26 °C outdoors.

For peak cooling, the EER2 of 8.8 is nothing remarkable. This system is chosen for winter, not for breaking records in July.

Back to certification, since it matters for your budget. No ENERGY STAR, no cold-climate recognition, and no LogisVert listing on the Hydro-Québec list as it stood on October 27, 2026: the “extra-low-temperature” designation comes from the manufacturer, and it entitles you to nothing. For a house this size, the lack of a grant is noticeable, and we would rather you know it before the visit than at signing.

Even with an extra-low-temperature model, a large house needs a plan B for the harshest nights. That role goes to the electric backup heat kit supplied by the manufacturer, field-installed in the air handler, which supplements the heat pump when demand exceeds what it delivers. The load calculation will tell us how much backup to plan for.

In the basement, the indoor unit runs between 29 dB(A) and 47 dB(A) depending on speed. Outside, the outdoor unit is rated at 54 dB(A) and stands 52.5 in. tall; on a large lot, there is a choice of location, and it sits on a base or bracket, sheltered from snow sliding off the roof and away from bedroom windows.

What AirGreen’s installation includes:

  • inspection of the existing ducts, plenum and return air, and a load calculation;
  • removal of the old unit where applicable, then installation of the AMUG48LMAS with a filter access hatch;
  • base or bracket, 208/230 V power supply, refrigerant line in 3/8 in. and 5/8 in. diameters, cable and drain to the outdoor unit;
  • commissioning by a refrigeration technician and a check of the air delivered to the farthest room.

Wi-Fi is available as an option. Outdoor unit and indoor unit operate in fully communicating mode, and the optional external input/output interface lets you interlock the heat pump with a third-party system already in the house.

A large house works its filter hard: check it often, especially during the months when the blower runs a lot. The condensate drain and the outdoor unit also deserve a look every season. The spec sheet shows a warranty of 12 years for the compressor, the same for parts, and 6 years for labour.

If winter is not your priority, or if you are keeping another heat source, the same indoor unit is also paired with the AOUG48LMAS1 outdoor unit in the 48LMAS1 system, which is not classed among the extra-low-temperature models. We can price both.

The 48LMAH1M suits these profiles well:

  • large two-storey houses with a basement, already fitted with ducts or ready to receive them;
  • owners set on an outdoor unit designed for extra-low-temperature heating who accept investing without a grant;
  • not projects where ENERGY STAR certification is required.

Sainte-Anne-de-Bellevue: have your basement and ducts assessed

In Sainte-Anne-de-Bellevue, the visit starts in the basement: clear height, location of the old unit, condition of the plenum and return air. It ends outside, where the outdoor unit will go. The quote that follows is free, written, and contains no make-believe grant amount.

Reach AirGreen, an HVAC contractor, at 514 316-2973. Our territory: Montreal, Laval and Longueuil, as well as the North Shore and the South Shore.