SAMSUNG Hylex Standard Central Heat Pump | 2 Tons - Montreal

In stock
SKU: 218158142
Provincial Subsidy (LogisVert): 0 $ (Updated: November 26, 2025)
Model Number (External): AC024FCUDCG
Model Number (Interior): HH24MCAC11H1
AHRI: 218158142
ENERGY STAR®: No
ENERGY STAR® (Cold Climate): No / No
# ENERGY STAR ID: -
Heating Capacity (Heat Pump): -25 °C
Cooling Capacity: 24,000 BTU
Gas (Freon): R-454B
WiFi: Included

SEER2 (Seasonal Air Conditioning Efficiency)

1 15.2 30

HSPF2 (Seasonal heating efficiency)

1 8.0 15

EER2 (Instantaneous efficiency in air conditioning)

1 10.5 20

COP at -8 °C (Heating energy efficiency)

1 1.69 3
Size: 2 Tons
Nominal Power: 24,000 BTU
Power at -8°C: 14900 BTU
Power at -15°C: 18200 BTU
Interior Dimensions (L x D x H): 15 x 22 x 36 in
Dehumidification: pt/h
Sound Pressure Level (Indoor): TBD dB(A)

CFM (Airflow)

1 809 1500
External Dimensions (L x W x H): 37 x 13 x 39.31 in
Piping: 3/8 - 3/4
Sound Pressure Level (Exterior): 52.0 dB(A)
Voltage: 220 V
MCA (Minimum Circuit Ampacity): 25 A
MOP (Maximum Overcurrent Protection): 30 A
Warranty (Compressor - Parts - Labor): 12-12-0 years
Additional Warranty: Possible

(French brochure coming soon)

A Modern Central HVAC Solution Designed for Greater Montreal's Reality

In the field of residential HVAC in Montreal, Laval, Longueuil, the North Shore, and the South Shore, needs are evolving rapidly: replacement of old systems, increased energy efficiency, compatibility with existing infrastructures, and reliable performance in Quebec winters. The SAMSUNG Hylex Standard 2-ton central heat pump precisely addresses these challenges.

At AirGreen, we regularly install this type of system in modernization projects where homeowners wish to keep part of their existing installation while significantly improving their thermal comfort. This model stands out for its universal inverter design, capable of effectively replacing a traditional central unit without requiring a complete system overhaul.


Why the SAMSUNG Hylex 2-ton stands out in HVAC projects

Exceptional compatibility with existing systems

One of the major advantages of the Hylex is its ability to reuse existing ducts, piping, and even some wiring. Concretely, this allows for:

  • Reduced costs of HVAC installation in Montreal
  • Decreased construction time
  • Less invasive work in the home

According to technical documentation, the Hylex operates with only 2 low-voltage wires between the indoor and outdoor units, significantly simplifying installation.

In several projects carried out in Laval and Longueuil, we have replaced old central units while keeping the ducts and refrigerant lines, which saved our clients several thousand dollars in labor.


Real performance adapted to Quebec winters

The heat pump offers heating capacity down to -25°C, with stable performance even at low temperatures. This makes it a viable solution for Quebec's climate.

Key data:

  • Nominal capacity: 24,000 BTU
  • Effective heating down to: -25°C
  • Capacity at -8°C: 14,900 BTU
  • Capacity at -15°C: 18,200 BTU

Inverter technology allows for continuous power modulation, avoiding the typical on/off cycles of older systems. The result:

  • More stable temperature
  • Reduced energy consumption
  • Less mechanical wear

R-454B Refrigerant: a more responsible choice

The Hylex uses R-454B gas, a refrigerant with a low global warming potential (GWP). This is a key element for environmentally conscious homeowners and for future energy standards.

This type of refrigerant is gradually becoming the standard in HVAC installations in Montreal and Montérégie, particularly in recent residential projects.


Smart operation and advanced connectivity

The system is compatible with the Samsung SmartThings platform, allowing for:

  • Energy consumption monitoring
  • Real-time error notifications
  • Remote adjustment via WiFi
  • Automatic comfort optimization

With a compatible controller, the heat pump can even use advanced functions such as:

  • Adjustment based on occupant habits
  • Intelligent energy management

These features are particularly appreciated in modern homes on the South Shore and Greater Montreal, where clients seek to automate their comfort.


HVAC Installation: what we've learned in the field

Real Case – Replacement in Montreal (Rosemont)

A client had an old, inefficient central unit with a gas furnace. We installed a Hylex in a bi-energy (dual fuel) configuration:

  • Heat pump for moderate temperatures
  • Furnace as auxiliary heating in extreme cold

Result:

  • Significant reduction in energy costs
  • Improved comfort
  • Installation completed in 1.5 days thanks to system compatibility

Common mistakes to avoid

In our HVAC installation projects in Laval and Longueuil, certain mistakes often recur:

  1. Incorrect sizing
    • A 2-ton unit must match the actual thermal load
  2. Ignoring coil compatibility
    • The Hylex works with a specific TXV coil
  3. Forgetting the ACU (control module)
    • Mandatory component for system operation
  4. Installation without airflow optimization
    • Direct impact on performance and lifespan

At AirGreen, we systematically validate these elements before any installation.


Detailed technical specifications

Main specifications

  • Outdoor model: AC024FCUDCG
  • Indoor model: HH24MCAC11H1
  • AHRI: 218158142
  • Voltage: 220V
  • MCA: 25A
  • MOP: 30A

Energy performance

  • SEER2: 15.2
  • HSPF2: 8.0
  • EER2: 10.5
  • COP at 5°F: 1.69

Dimensions

  • Indoor: 15 x 22 x 36 inches
  • Outdoor: 37 x 13 x 39.31 inches

Sound level

  • Outdoor: approximately 50–52 dB(A)
    Compared to traditional systems at 68 dB, this is a notable noise reduction.

Installation flexibility: a strategic advantage

The Hylex can be installed in several configurations:

  • With an air handler (AHU)
  • With a furnace + A-coil
  • As a hybrid dual-energy system

It also allows for:

  • Piping length up to 164 feet
  • Height difference up to 98 feet

This opens up significant possibilities for:

  • Row houses
  • Properties with limited access
  • Multi-unit projects

Why choose AirGreen for your HVAC installation

Real field expertise

We have installed hundreds of systems in:

  • Montreal
  • Laval
  • Longueuil
  • North Shore
  • South Shore

Each project is meticulously analyzed:

  • Thermal load calculation
  • Duct validation
  • Energy optimization

Transparency and quality of execution

  • Clear pricing before work
  • No surprise fees
  • Installation according to best practices:
    • Vacuum pulling
    • Leak tests
    • Complete calibration

Reliable after-sales service

  • Prompt support
  • Accurate diagnostics
  • Structured customer follow-up

Conclusion: an ideal central heat pump for smart replacements

The SAMSUNG Hylex Standard 2-ton central heat pump is particularly suited for replacement projects in Greater Montreal. Its compatibility, cold climate performance, and installation flexibility make it a strategic solution for upgrading an existing HVAC system without rebuilding everything.


Contact AirGreen

For HVAC installation in Montreal, Laval, Longueuil, the North Shore, or the South Shore, contact our team now. We will offer you a tailored, precise, and optimized solution for your property.