27,000BTU/h · 2 heads
−25 °Cheats down to
ENERGY STAR® cold climateOptional Wi-FiR-454BUp to 4 heads
Talk to a technician · 514 316-2973
Outdoor unit BMS500-AAM027-1CSXRDPossible indoor models BMS500-AAU006-1AHWXD, BMS500-AAU009-1AHWXD, BMS500-AAU012-1AHWXD, BMS500-AAU018-1AHWXDAHRI 215223333· ENERGY STAR 3554586
In short

The Thermopompe Double Zone BOSCH Régulier R-454b | Compresseur 27 000 BTU | Montréal, Laval, Longueuil, Rive Sud & Rive Nord multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 21,600 BTU/h at −8 °C, heats down to −25 °C. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 215223333
21,600BTU/h at −8 °C
−25 °Cstill heating
2 → 4heads, on the same unit
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

BMS500-AAM027-1CSXRD

Outdoor unit

One compressor for the whole house. It supplies up to 4 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · Deep cold

At −15 °C, it still delivers 70 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

06 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

07 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling23.0
Scale 1 – 30
HSPF2 · seasonal heating9.3
Scale 1 – 15
EER2 · cooling in peak heat12.5
Scale 1 – 20
COP at −15 °C2.0
Scale 0 – 4
08 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVertPer the listDepends on each model

We compare both options on your floor plan during the estimate.

09 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up.
10 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)27,000 BTUSheet
SEER2 (seasonal cooling efficiency)23.0AHRI
EER2 (instant cooling efficiency)12.5AHRI
HSPF2 (seasonal heating efficiency, region IV)9.3AHRI
Heating
Capacity at −8 °C21,600 BTU/hSheet
Capacity at −15 °C18,900 BTU/h · COP 2.0Sheet
Heats down to−25 °CSheet
Zones and heads
Zones on this product2 Zones (Double Zone)Sheet
Maximum zones4 Zones (Quad Zone)Sheet
Possible indoor modelsBMS500-AAU006-1AHWXD, BMS500-AAU009-1AHWXD, BMS500-AAU012-1AHWXD, BMS500-AAU018-1AHWXDSheet
Installation
Electrical
Voltage220 VSheet
RefrigerantR-454BSheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI215223333AHRI
ENERGY STARYes · cold climate · ID 3554586Sheet
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
11 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 21,600 BTU/h at −8 °C, 18,900 at −15 °C.

How many heads can I connect?

Up to 4 on this outdoor unit. This product is configured for 2 heads.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3554586.

Down to what temperature does it heat?

Down to −25 °C.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.