SHARP Dual Zone Heat Pump | R32 -30°C

In stock
SKU: AE-X3M24CU
24,000BTU/h
−30 °Cheats down to
$3,000LogisVert, indicative
ENERGY STAR® cold climateENERGY STAR Most EfficientWi-Fi includedR-32

Arrive le 1er janvier 2027

Talk to a technician · 514 316-2973
Outdoor unit AE-X3M24CUPossible indoor models AY-XPC9CU, AY-XPC12CU, AY-XPC18CU, AY-XPC18CU-BAHRI 217512785· ENERGY STAR 4439340
In short

The Sharp CU 24 000 multi-zone heat pump heats and cools 0 rooms with a single outdoor unit. it delivers 25,000 BTU/h at −8 °C, heats down to −30 °C and qualifies for a $3,000 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

One outdoor unit, and the most powerful in its class at −8 °C.

Compared with the 59 multi-zone systems of 24,000 BTU we sell. Every number on this page carries its source.

ENERGY STAR Most EfficientNEEP 507381AHRI 217512785LogisVert · October 1, 2026
+SEER2 24.0Rank 1 (tied) of 59. Class median: 21.0.
+25,000 BTU/h at −8 °CRank 1 (tied) of 57. Class median: 17,400 BTU/h.
+$3,000 LogisVert grantRank 1 (tied) of 45. Class median: $2,088.
25,000BTU/h certified at −8 °C
−30 °Cstill heating
2.53COP at −8 °C
$3,000LogisVert, indicative
02 · Videos

Before the numbers, watch it run.

03 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

04 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones
24,000BTU
3

Sharp CU 24 000

25,000 BTU/h
at −8 °C
$3,000
LogisVert

Up to 0 heads on this outdoor unit. Tap another box to see that size.

05 · Deep cold

At −15 °C, it still delivers 88 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
8,800 → 30,000 BTU/h
-8 °C
7,600 → 25,000 BTU/h
-15 °C
8,400 → 21,200 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
06 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

07 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling24.0
Scale 1 – 30Median: 21
Rank 1 (tied) of 59 in its class.
HSPF2 · seasonal heating11.5
Scale 1 – 15Median: 10
Rank 1 (tied) of 59 in its class.
EER2 · cooling in peak heat14.0
Scale 1 – 20Median: 12.5
Rank 4 (tied) of 57 in its class.
COP at −15 °C2.3
Scale 0 – 4Median: 2
Rank 3 (tied) of 51 in its class.
ENERGY STAR Most EfficientCold climate · ID 4439340 · ENERGY STAR database
08 · LogisVert grant

A grant you can calculate, not guess.

25,000 BTU/h÷ 1,000 ×$120=$3,000

The capacity at −8 °C comes from Hydro-Québec’s list of October 1, 2026. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 217512785). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
09 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 59 multi-zone systems of 24,000 BTU we sell, using the LogisVert list figures. Weaknesses too, said plainly.

10 · Head-to-head

Against three other brands in its class.

Same rated size, other manufacturers. Pick the opponent.

11 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone0 wall units
On the wall1 outdoor unit0 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$3,000 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

12 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

27.94 in
AE-X3M24CUDepth 13 in
33.47 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
25 A max. breaker
MCA  A · 220 V
Outdoor unit
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, 25 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
13 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

23
43
54
27
58
20 dB(A)3040506070
23 Reference head, lowest speed43 Reference head, highest speed27 Class indoor median54 Outdoor unit58 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
14 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

Most EfficientENERGY STARAmong the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
8,800BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
−30 °CColdest certified pointNEEP still lists 13,000 BTU/h at a COP of 1.72 at −22 °F.
675R-32 GWPGlobal warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
15 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)24,000 BTUSheet
Certified cooling at 35 °C24,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)24.0AHRI
EER2 (instant cooling efficiency)14.0AHRI
HSPF2 (seasonal heating efficiency, region IV)11.5AHRI
HSPF2, region V (coldest)9NEEP
Heating
Capacity at +8.3 °C26,000 BTU/h · COP 4.35NEEP
Capacity at −8 °C25,000 BTU/h · COP 2.53NEEP
Capacity at −15 °C21,200 BTU/h · COP 2.3NEEP
Capacity at -30 °C (max.)13,000 BTU/h · COP 1.72Sheet
Modulation range8,800 – 25,000 BTU/hNEEP
Heats down to−30 °CSheet
Zones and heads
Possible indoor modelsAY-XPC9CU, AY-XPC12CU, AY-XPC18CU, AY-XPC18CU-BSheet
Indoor dimensions (W × D × H)34.61 x 9.02 x 11.38 inSheet
Vertical louversAutoSheet
Horizontal louversManualSheet
Airflow (reference head)438 CFMSheet
Indoor sound (reference head)23 – 43 dB(A)Sheet
Installation
Outdoor unit (W × D × H)33.47 x 13 x 27.94 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound54 dB(A)Sheet
Electrical
Voltage220 VSheet
MOP (maximum overcurrent protection)25 ASheet
RefrigerantR-32Sheet
Wi-FiIncludedSheet
Certifications and warranty
AHRI217512785AHRI
ENERGY STARYes · cold climate · ID 4439340ENERGY STAR
ENERGY STAR Most EfficientYesENERGY STAR
LogisVert grant (indicative)$3,000LogisVert
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
16 · Official brochures

The manufacturer’s documentation, as PDF.

17 · Description

Everything we have written about this system.

A DualZone heat pump designed for Quebec's harsh winters

At AirGreen, we install HVAC systems in single-family homes, duplexes, condos, and small multi-unit buildings throughout Montreal, Laval, Longueuil, and on the North and South Shores . The SHARP CU Dual Zone Heat Pump | R32 -30°C is one of the solutions we recommend when our clients want to heat and cool two separate spaces with a single, high-performance outdoor compressor that is reliable and suitable for extreme temperatures.

The AE-X3M24CU outdoor model, with a nominal capacity of 24,000 BTU , is designed to operate efficiently down to -30°C in heating mode , which is essential for Quebec's climate. Unlike many entry-level systems that quickly lose efficiency below -15°C, this series is ENERGY STAR® (Cold Climate) certified and offers measured and documented performance.

Key technical specifications

  • Cooling capacity: 24,000 BTU

  • Power at -8°C: 25,000 BTU

  • Power at -15°C: 21,200 BTU

  • Refrigerant: R-32

  • SEER2: 24.0

  • HSPF2: 11.5

  • EER2: 14.0

  • Outdoor noise level: 54 dB(A)

  • Voltage: 220V

  • Warranty: 10 years compressor – 10 years parts – 6 years labor straight from the distributor (extended warranty available)

We always analyze this data in relation to the reality of the building: insulation, surface area, room configuration, orientation, ceiling height and heating habits.


Coanda air diffusion technology: comfort without direct drafts

One of the key features of the SHARP CHU/CU series is the Coanda Airflow technology. This technology allows air to circulate along the ceiling in cooling mode and along the floor in heating mode, thus avoiding an uncomfortable direct blow.

Specifically, during an installation we carried out in a condo in Boucherville (South Shore) , the owners complained of drafts with their old wall-mounted system. After installing the SHARP DoubleZone CU, the more diffused air distribution significantly improved comfort in the living room and master bedroom.

Note: Differences between CU and CHU series

It is important to clarify that:

  • The CU series does not have a motion sensor .

  • The horizontal left-right flaps are not automatic on the CU series (manual adjustment).

These features are present on some CHU units, but not on the CU. At AirGreen, we always explain these distinctions to our clients to avoid any confusion when choosing a model.


DoubleZone: an efficient solution for two separate spaces

The DoubleZone configuration allows you to connect up to two indoor units (from the compatible models AY-XPC9CU, AY-XPC12CU, AY-XPC18CU and AY-XPC18CU-B) to a single AE-X3M24CU outdoor compressor.

Real-life case: duplex in Laval

We recently installed this setup in a duplex in Laval :

  • 1 unit 12,000 BTU for the ground floor (open concept kitchen/living room).

  • 1 unit 9000 BTU for the floor (master bedroom).

The objective was twofold:

  1. Replacing an old, expensive electrical system.

  2. Avoid installing two external compressors for aesthetic and space reasons.

Result: significant reduction in winter consumption and improvement in thermal comfort, even during cold spells in January.


Energy efficiency and subsidies in Quebec

The SHARP CU Dual Zone Heat Pump | R32 -30°C is eligible for the LogisVert Grant (updated November 2025: $3,000) according to the criteria in force.

Thanks to its performance:

  • SEER2 24.0 in air conditioning

  • HSPF2 11.5 in heating

It meets the energy efficiency requirements sought by many homeowners in Montreal, Longueuil and on the North Shore .

We support our clients in:

  • Eligibility verification.

  • Technical documentation (AHRI number: 217512785).

  • Preparing the forms.


R-32 refrigerant: efficiency and reduced environmental impact

The system uses R-32 gas, which is more thermally efficient than R-410A and has a lower global warming potential (GWP).

In our projects to replace older heat pumps in Montreal East , we often observe:

  • An improvement in performance.

  • A reduction in the refrigerant charge.

  • Improved stability in cold weather.

This contributes to a more sustainable solution for homeowners concerned about their environmental footprint.


Professional HVAC Installation: A Determining Factor

A high-performance heat pump that is poorly installed will never deliver the expected results.

At AirGreen, each installation includes:

  • Precise calculation of thermal loads.

  • Electrical panel check (MOP 25A).

  • Certified vacuum extraction.

  • Pressure tests.

  • WiFi configuration included.

  • Full explanation to the customer.

A common mistake to avoid

We regularly see installations where:

  • The refrigeration lines are undersized.

  • The drain is not properly sloped.

  • The outdoor wall mount transmits vibrations.

These details directly affect the compressor's lifespan and acoustic comfort. Our team of experienced refrigeration technicians systematically corrects these issues.


Noise level and everyday comfort

With an indoor noise level ranging from 23 to 43 dB(A) depending on the indoor model chosen, this heat pump is perfectly suited:

  • To the bedrooms.

  • At home offices.

  • To condominiums.

Outside, the 54 dB(A) remains within a comfortable range for residential environments in Longueuil and Laval , where the proximity of neighbors requires rigorous acoustic control.


Mobile app and simplified maintenance

WiFi is included, allowing:

  • Schedule.

  • Remote adjustment.

  • Monitoring of operations.

The After Care function helps to dry the indoor unit after use to limit internal humidity.

For HVAC maintenance, we recommend:

  • Clean the filters every 1 to 3 months.

  • Annual professional review.

  • Condensation drain inspection.


Why choose AirGreen for your SHARP heat pump in Montreal and surrounding areas?

We don't just sell a product. We analyze:

  • The actual configuration of the building.

  • Municipal constraints.

  • Grant requirements.

  • The client's budget objectives.

With our $5,000,000 liability insurance, our RBQ #5645-9605-01 and our specialized HVAC installation teams in Montreal, Laval, Longueuil, North Shore and South Shore , we ensure a structured and transparent service.


Conclusion: a DoubleZone solution adapted to the Quebec climate

The SHARP CU Dual Zone Heat Pump | R32 -30°C combines:

  • Performance in cold climates.

  • High energy efficiency.

  • Flexible two-zone configuration.

  • Modern refrigerant R-32.

  • Coanda comfortable air distribution.

For a condo, duplex or house requiring two separate zones, it represents a solid option when the installation is properly sized and executed.


Contact AirGreen

To obtain a detailed quote, check your eligibility for subsidies, or schedule a technical visit in Montreal, Laval, Longueuil, on the North Shore or South Shore , contact us today. Our team will guide you toward the configuration best suited to your property.

Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.

18 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 25,000 BTU/h at −8 °C, 21,200 at −15 °C.

How much is the LogisVert grant?

$3,000 according to Hydro-Québec’s list of October 1, 2026. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 4439340. It also meets the ENERGY STAR Most Efficient criteria, according to the ENERGY STAR database.

Down to what temperature does it heat?

Down to −30 °C.

Is it noisy?

Indoors, the reference head goes down to 23 dB(A). Outdoors, 54 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $3,000AHRI 217512785 checked against the list of October 1, 2026
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 507381 (AHRI 217512785): capacities and COP, modulation, SEER2, EER2, HSPF2.ENERGY STAR certified heat pump database, ID 4439340.Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 1, 2026; participation guide, version 1.10.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.