Kinghome Versati IV 5-Ton Air-to-Water Monobloc Heat Pump | Montréal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: KRSCQ16HGD
60,000BTU/h · nominal capacity
−25 °Cheats down to
COP 4.4published by the manufacturer
MonoblocR-3212-yr compressor, 12-yr parts

A heat pump that heats water instead of air

Most heat pumps installed in Québec heat air. This one heats water. The 5-ton (60,000 BTU) Versati IV air-to-water monobloc draws heat from the outdoor air and transfers it to a water loop that feeds radiant floor heating, radiators, hydronic fan coils and, if you add a tank, your domestic hot water. It's the solution we recommend for houses and small buildings already heated with hot water, or for new construction where radiant floors are planned from the start.

In practical terms, it replaces or backs up an electric, gas or oil boiler. The pipes, floor loops and radiators stay in place; only the heat source changes.

Monobloc: the refrigerant stays outside

The entire refrigerant circuit is contained in the outdoor unit, factory-charged with 2.2 kg of R-32. What comes into the house isn't a refrigerant line but two water pipes, connected with 1-inch BSPP fittings. That means no refrigerant connections to make on site, no indoor unit to find room for, and no refrigerant inside the building. The unit has a built-in variable-speed circulation pump, and a wired controller comes with it.

The outdoor unit measures 47.48 x 17.52 x 34.57 inches. Its published sound level is 56 dB(A), so it can go in a backyard in Laval or on the North Shore without bothering the neighbours, as long as the clearances are respected.

Three uses from a single unit

The system handles several operating modes, and temperature control by emitter type lets it supply each circuit with the water it needs:

  • Radiant floor heating: lukewarm water circulates through the floor loops. This is where an air-to-water heat pump performs best, because the floor doesn't need very hot water.
  • Heating with radiators or fan coils: these emitters need hotter water, which the unit produces by raising its set point.
  • Cooling with fan coils: in summer, the unit produces chilled water for hydronic fan coils. Radiant floors, on the other hand, are not used to cool a house.
  • Domestic hot water: the unit produces water at up to 65 °C to heat a hot water tank. The tank is not included and must be purchased separately, with a compatible heat exchange coil.

Efficiency and operating limits

The manufacturer's data sheet gives a COP of 4.4 and an EER of 11.8. A COP of 4.4 means that, under test conditions, the unit delivers more than four times as much heat as the electricity it uses. That efficiency drops as it gets colder outside and as the water called for gets hotter, which is why a well-designed radiant floor gets the most out of this type of unit.

The heating operating range runs from -25 °C to 35 °C outdoors, and the cooling range from -15 °C to 48 °C. Below -25 °C, the unit shuts down: that is a significant limit in Québec, and it means you need backup heat. The unit includes a 6 kW electric backup element according to the spec sheet, and an emergency mode switches heating over to the backup if the heat pump fails. An existing boiler can also be kept as a second heat source. For larger buildings, several units can be linked together, with the controller adjusting their operation and frequency to match demand.

What we check before installation

A hydronic installation calls for design work, not just swapping one appliance for another. Here is what we validate during a visit in Montréal, Laval, Longueuil, on the North Shore or on the South Shore.

Emitters and water temperature

We take stock of the floor loops, radiators and fan coils, and we work out the water temperature each one needs to heat the house in very cold weather. Older radiators sized for a very hot boiler can fall short with cooler water; we say so in the quote and we propose solutions, such as adding emitters or a larger backup.

Electrical supply

The unit requires a minimum circuit ampacity (MCA) of 37 A and a maximum overcurrent protection (MOP) of 60 A. The backup element is powered separately. If the unit replaces an electric boiler, the existing electrical service is often enough; if it replaces a gas or oil boiler, we do a load calculation on the electrical panel before confirming.

Location and freeze protection

The outdoor unit contains water. It must sit on a stand or base that keeps it above the snow and lets defrost water drain away, and the water pipes between the unit and the house must be short, insulated and protected against freezing. Depending on the installation, we add an antifreeze mix to the loop or equivalent protection, so that a power outage in January doesn't freeze the heat exchanger.

The hydronic circuit

We check the system's water volume, the water quality, whether there is a buffer tank where the loops are many and short, the expansion tank, the air vents and the isolation valves. For domestic hot water, we choose a compatible coil tank and a diverting valve between heating and hot water.

LogisVert assistance

This unit does not appear on Hydro-Québec's LogisVert list in effect for an installation on October 28, 2026, because it is not ENERGY STAR certified; eligibility is confirmed on the installation date. We would rather tell you before the quote than let you count on a rebate that won't come through.

Why go with AirGreen

  • Salaried refrigeration technicians who handle the hookup, commissioning and tuning of the temperature curves.
  • Civil liability insurance of $5,000,000.
  • Warranty registration handled by us.
  • After-sales service for maintaining the loop and the outdoor unit.

Request your free estimate for the Versati IV air-to-water monobloc: we assess your emitters, your panel and your water loop, then give you a clear quote.

Documentation

Warranty: 12 years on the compressor and parts for residential use, on registered models; 7 years on the compressor and 5 years on parts for commercial use.