Kinghome Rooftop R410A 5-Ton Packaged Heat Pump | Montréal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: KRH05TCU

The largest capacity in the lineup for very busy spaces

A daycare, a restaurant dining room, a community hall, a fitness studio or the common areas of a small condo building all have one thing in common: a lot of people sharing the same volume of air. Every occupant adds heat and humidity, and the cooling load climbs fast as soon as the room fills up. The KRH05TCU, a 5-ton rooftop packaged heat pump, is the model in the lineup designed for these flat-roof light commercial spaces.

Like the other models in the series, it brings the compressor, the coils and the fans together in a single cabinet, and it connects to the building's ductwork through a roof curb. Nothing takes up floor space, the front of the building or the back lane.

Cooling: the reason to choose five tons

The unit is certified at 17 SEER2 and an EER2 of 10.6. The inverter rotary compressor modulates its speed: at noon, when the dining room fills up, it ramps up; by mid-afternoon, it slows down and holds the set point while it keeps pulling out humidity. This modulation avoids the cold, clammy air you get from big fixed-speed units, which reach the temperature too fast and then shut off.

We do need to be clear about one thing: in heating, this model doesn't deliver more than the four-ton. We recommend the five-ton when it's the cooling needs, assessed on site with the actual occupancy, that call for it.

Published heating capacities

The unit is certified at 8.3 HSPF2. Its heating capacities, listed on NEEP (AHRI No. 213685843), read as follows:

  • At -8.3 °C: 37,000 BTU/h, with a COP of 2.38
  • At -15 °C: 45,000 BTU/h, with a COP of 1.8
  • At -30 °C: 36,000 BTU/h, with a COP of 1.37

At -15 °C, it delivers 75% of its 60,000 BTU/h nominal capacity, and it still keeps 60% of that value at -30 °C, with a COP above 1. A very busy space generally has a lower heating load than cooling load, precisely because of the heat given off by the occupants and the equipment; these capacities are therefore often enough, but we confirm it with an on-site assessment of heating needs. The value at -15 °C is higher than the one at -8.3 °C, as stated on the certificate. The heating range goes down to -30 °C, and the unit carries the ENERGY STAR cold climate designation (ID 2842327).

Construction and controls

The refrigerant circuit is assembled, charged with R-410A and sealed at the factory: no refrigerant line runs through the building. The duct connection is horizontal or downflow. The outdoor coil gets a Golden Fin anti-corrosion treatment, the unit has been salt-spray tested and the smart defrost adapts to actual conditions. The controls accept a conventional low-voltage thermostat or digital communication. The dimensions are 44.00 x 44.00 x 49.25 inches, the same cabinet as the four-ton, and the published sound level is 68 dB(A).

Fresh air, a topic to handle at the same time

A very busy space also needs fresh air. The heat pump heats and cools the recirculated air, but the outdoor air supply is planned separately, with an air exchanger or a heat recovery ventilator sized for the occupancy. We take it into account in the quote, because untreated fresh air adds a load the unit has to absorb.

Noise and the neighbours

With a published sound level of 68 dB(A), the spot on the roof has to be chosen carefully when neighbouring homes have windows or a terrace nearby, a common situation in the mixed-use neighbourhoods of Montréal. We place the unit as far as possible from residential openings, we point the outdoor fan discharge toward the least sensitive side, and we check the borough's or municipality's requirements for rooftop mechanical equipment. A roof curb that's well isolated from vibration also keeps compressor noise from travelling into the building structure.

What we check before the installation

Here's what we confirm when we visit a building in Montréal, Laval, Longueuil, on the North Shore or on the South Shore.

The on-site assessment with the actual occupancy

We assess cooling needs on site based on the number of people, the kitchen or exercise equipment, the lighting and the glazing, then the heating needs based on the roof insulation and the fresh air supply. If the four-ton is enough, we recommend it.

The electrical supply

The unit requires a 220 V single-phase supply, an MCA of 40 A and a maximum overcurrent protection (MOP) of 45 A. We check the space's panel, the gauge of the cable up to the roof and the installation of a disconnect near the unit.

The structure, access and snow

We confirm the roof's load-bearing capacity and the condition of the membrane, and we plan the crane lift. The roof curb keeps the unit above the snow buildup; the condensate drain is connected with a trap to a roof drain, and the defrost water must not freeze on the membrane.

Ductwork and air distribution

In a large room, where the diffusers and returns go matters as much as the capacity. We check that the air reaches the occupied areas without creating drafts over the tables or the play areas.

LogisVert assistance

This unit is on Hydro-Québec's LogisVert list with an indicative amount of $4,440; eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The program targets residential buildings; the common areas of a residential building may be eligible, a business generally isn't. The file references are AHRI 213685843 and ENERGY STAR ID 2842327.

Why go with AirGreen

  • Salaried refrigeration technicians who schedule the work around your business hours.
  • Civil liability insurance of $5,000,000.
  • Warranty registration handled by us.
  • After-sales service for regular maintenance on the roof.

Ask for your free estimate for the 5-ton rooftop packaged unit: we assess the heating and cooling needs of your space on site with its actual occupancy, check the roof and the panel, then give you a detailed quote.

Documentation

Warranty: 5 years on the compressor and 7 years on parts, on registered models, according to the Kinghome brochure.