FORESTAIR MZ R454B 2-Zone Wall-Mounted Heat Pump | Ext: 18000 BTU

In stock
SKU: FA-M18-D2TL-O-454--2
18,000BTU/h · 2 heads
−25 °Cheats down to
$2,400LogisVert, indicative
ENERGY STAR® cold climateENERGY STAR Most EfficientWi-Fi includedR-454BUp to 2 heads
Talk to a technician · 514 316-2973
Outdoor unit FA-M18-D2TL-O-454Possible indoor models FA-H09-D24TL-I-454, FA-H12-D24TL-I-454AHRI 217512361· ENERGY STAR 4529624
In short

The ForestAir MZ R454B 18 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. it delivers 20,000 BTU/h at −8 °C, heats down to −25 °C and qualifies for a $2,400 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Compared with the 48 multi-zone systems of 18,000 BTU we sell. Every number on this page carries its source.

ENERGY STAR Most EfficientNEEP 508679AHRI 217512361LogisVert · October 1, 2026
+HSPF2 10.5Rank 3 (tied) of 46. Class median: 10.0.
+20,000 BTU/h at −8 °CRank 2 (tied) of 45. Class median: 15,000 BTU/h.
+$2,400 LogisVert grantRank 1 (tied) of 37. Class median: $1,800.
!Good to know: indoor head from 30 dB(A)Rank 39 of 45; class median: 27 dB(A).
20,000BTU/h certified at −8 °C
−25 °Cstill heating
2heads
2.61COP at −8 °C
$2,400LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

FA-M18-D2TL-O-454

Outdoor unit

One compressor for the whole house. It supplies up to 2 heads and modulates from 3,500 to 20,000 BTU/h depending on what the rooms call for (NEEP).

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
Here
27,000BTU
23
36,000BTU
234
42,000BTU
2345

ForestAir MZ R454B 18 000 · 2 zones

20,000 BTU/h
at −8 °C
$2,400
LogisVert

Up to 2 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 88 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
3,500 → 22,000 BTU/h
-8 °C
3,200 → 20,000 BTU/h
-15 °C
2,600 → 16,000 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling24.0
Scale 1 – 30Median: 22
Rank 7 of 47 in its class.
HSPF2 · seasonal heating10.5
Scale 1 – 15Median: 10
Rank 3 (tied) of 46 in its class.
EER2 · cooling in peak heat13.0
Scale 1 – 20Median: 12.5
Rank 17 (tied) of 45 in its class.
COP at −15 °C2.0
Scale 0 – 4Median: 2
Rank 16 (tied) of 41 in its class.
ENERGY STAR Most EfficientCold climate · ID 4529624 · ENERGY STAR database
09 · LogisVert grant

A grant you can calculate, not guess.

20,000 BTU/h÷ 1,000 ×$120=$2,400

The capacity at −8 °C comes from Hydro-Québec’s list of October 1, 2026. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 217512361). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 48 multi-zone systems of 18,000 BTU we sell, using the LogisVert list figures. Weaknesses too, said plainly.

11 · Head-to-head

Against three other brands in its class.

Same rated size, other manufacturers. Pick the opponent.

12 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$2,400 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

13 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

27.5 in
FA-M18-D2TL-O-454Depth 15 in
36.5 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
25 A max. breaker
MCA 16 A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 16 A, 25 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
14 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

30
46
58
27
56
20 dB(A)3040506070
30 Reference head, lowest speed46 Reference head, highest speed27 Class indoor median58 Outdoor unit56 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
15 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

Most EfficientENERGY STARAmong the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
3,500BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
−25 °CColdest certified pointNEEP still lists 11,000 BTU/h at a COP of 1.22 at −13 °F.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
16 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)18,000 BTUSheet
Certified cooling at 35 °C18,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)24.0AHRI
EER2 (instant cooling efficiency)13.0AHRI
HSPF2 (seasonal heating efficiency, region IV)10.5AHRI
HSPF2, region V (coldest)9.5NEEP
Heating
Capacity at +8.3 °C20,000 BTU/h · COP 3.51NEEP
Capacity at −8 °C20,000 BTU/h · COP 2.61NEEP
Capacity at −15 °C16,000 BTU/h · COP 2.0NEEP
Capacity at -25 °C (max.)11,000 BTU/h · COP 1.22Sheet
Modulation range3,500 – 20,000 BTU/hNEEP
Heats down to−25 °CSheet
Zones and heads
Zones on this product2 Zones (Dual Zone)Sheet
Maximum zones2 Zones (Dual Zone)Sheet
Possible indoor modelsFA-H09-D24TL-I-454, FA-H12-D24TL-I-454Sheet
Indoor dimensions (W × D × H)36.25 x 12 x 7.63 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)500 CFMSheet
Indoor sound (reference head)30 – 46 dB(A)Sheet
Installation
Outdoor unit (W × D × H)36.5 x 15 x 27.5 inSheet
Outdoor sound58 dB(A)Sheet
Base pan heater150 WNEEP
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)16 ASheet
MOP (maximum overcurrent protection)25 ASheet
RefrigerantR-454BSheet
Wi-FiIncludedSheet
Certifications and warranty
AHRI217512361AHRI
ENERGY STARYes · cold climate · ID 4529624ENERGY STAR
ENERGY STAR Most EfficientYesENERGY STAR
LogisVert grant (indicative)$2,400LogisVert
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
17 · Official brochures

The manufacturer’s documentation, as PDF.

18 · Description

Everything we have written about this system.

A High-Performance Dual-Zone HVAC Solution Adapted to Quebec's Climate Realities

At AirGreen, we daily install HVAC systems in Montreal, Laval, Longueuil, on the North Shore and the South Shore, and we're seeing a clear trend: clients are looking for reliable multi-zone systems that are efficient in winter and flexible for different spaces. The FORESTAIR MZ R454B 18,000 BTU 2-zone wall-mounted heat pump precisely meets these requirements.

This model stands out for its ability to serve two independent zones, while maintaining consistent performance even during periods of intense cold, an essential factor in our Quebec climate.


Why choose a dual-zone heat pump like the FORESTAIR MZ 18,000 BTU

Smart management of two distinct spaces

In several projects carried out by AirGreen, particularly in Boucherville and Laval, we have installed this type of system in typical configurations:

  • A living room on the ground floor + a bedroom upstairs
  • A main dwelling + a finished basement
  • A duplex with distinct zones

Thanks to its 2 independent zones, this heat pump allows for:

  • An individual temperature control
  • An optimization of energy consumption
  • Personalized comfort for each occupant

Heating performance down to -25°C: a non-negotiable criterion

One of the most important elements for an HVAC installation in Quebec is heating capacity in winter. This model offers effective heating capacity down to -25°C, making it a solid choice for:

  • Single-family homes in Longueuil
  • Plexes in Montreal
  • Wind-exposed properties on the North Shore

According to the manufacturer's technical data, the unit can reach:

  • 20,000 BTU at 8°C
  • 16,000 BTU at -15°C

These performances significantly reduce the use of auxiliary heating, which means real savings for our clients.


Advanced technology and energy efficiency

High-efficiency DC Inverter

DC Inverter technology adjusts compressor power in real-time, thus avoiding energy-intensive on/off cycles.

Specifically, this means:

  • Stable temperature
  • Less wear and tear on components
  • Better overall efficiency

The measured performances are particularly interesting:

  • SEER2: 24.0
  • HSPF2: 10.5
  • EER2: 13.0

These values position this system among the high-performance energy-efficient options available on the Quebec market.


R-454B Refrigerant: a more responsible choice

The FORESTAIR MZ uses R-454B gas, a new generation refrigerant:

  • Less environmental impact than R-410A
  • Compliant with new standards
  • Better thermal efficiency

At AirGreen, we increasingly recommend this type of system, especially for clients concerned about energy efficiency and available subsidies.


Essential technical data to know

Here are the key elements to consider before installation:

Main features

  • Cooling capacity: 18,000 BTU
  • 2 zones (maximum 2 indoor units)
  • Voltage: 220V
  • Outdoor sound level: 58 dB(A)
  • WiFi included

Dimensions and installation

  • Outdoor unit: 36.5 x 15 x 27.5 inches
  • Weight: approximately 42 kg

According to the technical sheet, installation parameters include:

  • Maximum refrigerant line length: 40 m (131 feet)
  • Maximum length per zone: 25 m (82 feet)
  • Maximum elevation: 10 m (33 feet)

This data is crucial when planning, especially for complex installations such as:

  • Multi-story homes
  • Properties with architectural constraints
  • Renovation installations

Real experience: installation in Laval in a duplex

We recently installed this model in a duplex in Laval, where the client wanted to:

  • Air condition the main living room
  • Heat an upstairs bedroom

Challenges encountered:

  • Significant distance between units
  • Duct passage through a load-bearing wall
  • Minimizing noise for a family environment

Result:

  • Uniform comfort in both zones
  • Reduced energy consumption
  • No perceptible noise in the rooms

This type of project perfectly illustrates the versatility of this dual-zone wall-mounted heat pump.


Common mistakes to avoid with a multi-zone heat pump

At AirGreen, we have seen several poorly designed installations (often carried out without specialized HVAC expertise). Here are the mistakes to avoid:

Incorrect sizing

An 18,000 BTU system must be adapted to the surface area and insulation. Too small:

  • Lack of performance in winter
  • Overconsumption

Too large:

  • Short cycles
  • Premature wear

Poor zone distribution

Installing two poorly positioned zones leads to:

  • Poor air circulation
  • Thermal discomfort
  • Overall inefficiency

Non-compliant installation

Improper connection or incomplete vacuuming can compromise:

  • Compressor lifespan
  • Energy efficiency
  • Warranty

Subsidy and profitability in Quebec

This model is eligible for the LogisVert subsidy of $2400, making it a financially attractive option.

In several cases analyzed at AirGreen:

  • Return on investment in 3 to 5 years
  • Significant reduction in heating costs

Why choose AirGreen for your HVAC installation

Field expertise

Our refrigeration technicians install similar systems every week in:

  • Montreal
  • Laval
  • Longueuil
  • North Shore and South Shore

We master:

  • The constraints of Quebec buildings
  • Electrical standards (MCA 16A / MOP 25A)
  • Optimizing winter performance

Complete and transparent installation

Each project includes:

  • Complete thermal analysis
  • Precise sizing
  • Compliant installation
  • Professional commissioning

No surprises at the end of the project.


Real after-sales service

Unlike several market players, we provide:

  • Fast support
  • HVAC maintenance
  • Advanced diagnostics

Conclusion: a balanced, efficient, and Quebec-adapted dual-zone heat pump

The FORESTAIR MZ R454B 18,000 BTU 2-zone wall-mounted heat pump represents a reliable solution for homeowners who want to:

  • Heat efficiently in winter
  • Air condition two distinct zones
  • Optimize their energy consumption

It combines:

  • Performance
  • Flexibility
  • Compliance with new environmental standards

Contact AirGreen for a personalized quote

For an HVAC installation in Montreal, Laval, Longueuil, on the North Shore or the South Shore, our team supports you every step of the way.

Contact us today for:

  • A free evaluation
  • A recommendation adapted to your property
  • Professional installation without compromise

Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.

19 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 20,000 BTU/h at −8 °C, 16,000 at −15 °C.

How many heads can I connect?

Up to 2 on this outdoor unit. This product is configured for 2 heads.

How much is the LogisVert grant?

$2,400 according to Hydro-Québec’s list of October 1, 2026. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 4529624. It also meets the ENERGY STAR Most Efficient criteria, according to the ENERGY STAR database.

Down to what temperature does it heat?

Down to −25 °C.

Is it noisy?

Indoors, the reference head goes down to 30 dB(A). Outdoors, 58 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $2,400AHRI 217512361 checked against the list of October 1, 2026
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 508679 (AHRI 217512361): capacities and COP, modulation, SEER2, EER2, HSPF2.ENERGY STAR certified heat pump database, ID 4529624.Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 1, 2026; participation guide, version 1.10.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.