FORESTAIR MZ R454B 2-Zone Wall-Mounted Heat Pump | Ext: 18000 BTU

In stock
SKU: FA-M18-D2TL-O-454--2
Provincial Subsidy (LogisVert): 2400 $ (Updated: November 26, 2025)
Model Number (External): FA-M18-D2TL-O-454
AHRI: 217512361
ENERGY STAR®: Yes
ENERGY STAR® (Cold Climate): Yes / Yes
# ENERGY STAR ID: 4529624
Heating Capacity: -25 °C
Cooling Capacity: 18,000 BTU
Gas (Freon): R-454B
WiFi: Included

SEER2 (Seasonal Air Conditioning Efficiency)

1 24.0 30

HSPF2 (Seasonal heating efficiency)

1 10.5 15

EER2 (Instantaneous efficiency in air conditioning)

1 13.0 20

COP at -8 °C (Heating energy efficiency)

1 2.0 3
Nominal Power: 18,000 BTU
Power at -8°C: 20000 BTU
Power at -15°C: 16000 BTU
Interior Dimensions (L x D x H): 36.25 x 12 x 7.63 in ***
Vertical flap control (Air direction): Auto ***
Horizontal flap control (Air direction): Auto ***
Sound Pressure Level (Indoor): 30 / 46 dB(A) ***(depending on the model chosen)***
Possible Model Number (Interior): FA-H09-D24TL-I-454 and FA-H12-D24TL-I-454

CFM (Airflow) (12,000 BTU***)

1 500 700
External Dimensions (L x W x H): 36.5 x 15 x 27.5 in
Zones: 2 Zones (Dual Zone)
Maximum Zones: 2 Zones (Dual Zone)
Sound Pressure Level (Exterior): 58.0 dB(A)
Voltage: 220 V
MCA (Minimum Circuit Ampacity): 16 A
MOP (Maximum Overcurrent Protection): 25 A
Warranty (Compressor - Parts - Labor): 10-10-0 years
Additional Warranty: Possible

A High-Performance Dual-Zone HVAC Solution Adapted to Quebec's Climate Realities

At AirGreen, we daily install HVAC systems in Montreal, Laval, Longueuil, on the North Shore and the South Shore, and we're seeing a clear trend: clients are looking for reliable multi-zone systems that are efficient in winter and flexible for different spaces. The FORESTAIR MZ R454B 18,000 BTU 2-zone wall-mounted heat pump precisely meets these requirements.

This model stands out for its ability to serve two independent zones, while maintaining consistent performance even during periods of intense cold, an essential factor in our Quebec climate.


Why choose a dual-zone heat pump like the FORESTAIR MZ 18,000 BTU

Smart management of two distinct spaces

In several projects carried out by AirGreen, particularly in Boucherville and Laval, we have installed this type of system in typical configurations:

  • A living room on the ground floor + a bedroom upstairs
  • A main dwelling + a finished basement
  • A duplex with distinct zones

Thanks to its 2 independent zones, this heat pump allows for:

  • An individual temperature control
  • An optimization of energy consumption
  • Personalized comfort for each occupant

Heating performance down to -25°C: a non-negotiable criterion

One of the most important elements for an HVAC installation in Quebec is heating capacity in winter. This model offers effective heating capacity down to -25°C, making it a solid choice for:

  • Single-family homes in Longueuil
  • Plexes in Montreal
  • Wind-exposed properties on the North Shore

According to the manufacturer's technical data, the unit can reach:

  • 20,000 BTU at 8°C
  • 16,000 BTU at -15°C

These performances significantly reduce the use of auxiliary heating, which means real savings for our clients.


Advanced technology and energy efficiency

High-efficiency DC Inverter

DC Inverter technology adjusts compressor power in real-time, thus avoiding energy-intensive on/off cycles.

Specifically, this means:

  • Stable temperature
  • Less wear and tear on components
  • Better overall efficiency

The measured performances are particularly interesting:

  • SEER2: 24.0
  • HSPF2: 10.5
  • EER2: 13.0

These values position this system among the high-performance energy-efficient options available on the Quebec market.


R-454B Refrigerant: a more responsible choice

The FORESTAIR MZ uses R-454B gas, a new generation refrigerant:

  • Less environmental impact than R-410A
  • Compliant with new standards
  • Better thermal efficiency

At AirGreen, we increasingly recommend this type of system, especially for clients concerned about energy efficiency and available subsidies.


Essential technical data to know

Here are the key elements to consider before installation:

Main features

  • Cooling capacity: 18,000 BTU
  • 2 zones (maximum 2 indoor units)
  • Voltage: 220V
  • Outdoor sound level: 58 dB(A)
  • WiFi included

Dimensions and installation

  • Outdoor unit: 36.5 x 15 x 27.5 inches
  • Weight: approximately 42 kg

According to the technical sheet, installation parameters include:

  • Maximum refrigerant line length: 40 m (131 feet)
  • Maximum length per zone: 25 m (82 feet)
  • Maximum elevation: 10 m (33 feet)

This data is crucial when planning, especially for complex installations such as:

  • Multi-story homes
  • Properties with architectural constraints
  • Renovation installations

Real experience: installation in Laval in a duplex

We recently installed this model in a duplex in Laval, where the client wanted to:

  • Air condition the main living room
  • Heat an upstairs bedroom

Challenges encountered:

  • Significant distance between units
  • Duct passage through a load-bearing wall
  • Minimizing noise for a family environment

Result:

  • Uniform comfort in both zones
  • Reduced energy consumption
  • No perceptible noise in the rooms

This type of project perfectly illustrates the versatility of this dual-zone wall-mounted heat pump.


Common mistakes to avoid with a multi-zone heat pump

At AirGreen, we have seen several poorly designed installations (often carried out without specialized HVAC expertise). Here are the mistakes to avoid:

Incorrect sizing

An 18,000 BTU system must be adapted to the surface area and insulation. Too small:

  • Lack of performance in winter
  • Overconsumption

Too large:

  • Short cycles
  • Premature wear

Poor zone distribution

Installing two poorly positioned zones leads to:

  • Poor air circulation
  • Thermal discomfort
  • Overall inefficiency

Non-compliant installation

Improper connection or incomplete vacuuming can compromise:

  • Compressor lifespan
  • Energy efficiency
  • Warranty

Subsidy and profitability in Quebec

This model is eligible for the LogisVert subsidy of $2400, making it a financially attractive option.

In several cases analyzed at AirGreen:

  • Return on investment in 3 to 5 years
  • Significant reduction in heating costs

Why choose AirGreen for your HVAC installation

Field expertise

Our refrigeration technicians install similar systems every week in:

  • Montreal
  • Laval
  • Longueuil
  • North Shore and South Shore

We master:

  • The constraints of Quebec buildings
  • Electrical standards (MCA 16A / MOP 25A)
  • Optimizing winter performance

Complete and transparent installation

Each project includes:

  • Complete thermal analysis
  • Precise sizing
  • Compliant installation
  • Professional commissioning

No surprises at the end of the project.


Real after-sales service

Unlike several market players, we provide:

  • Fast support
  • HVAC maintenance
  • Advanced diagnostics

Conclusion: a balanced, efficient, and Quebec-adapted dual-zone heat pump

The FORESTAIR MZ R454B 18,000 BTU 2-zone wall-mounted heat pump represents a reliable solution for homeowners who want to:

  • Heat efficiently in winter
  • Air condition two distinct zones
  • Optimize their energy consumption

It combines:

  • Performance
  • Flexibility
  • Compliance with new environmental standards

Contact AirGreen for a personalized quote

For an HVAC installation in Montreal, Laval, Longueuil, on the North Shore or the South Shore, our team supports you every step of the way.

Contact us today for:

  • A free evaluation
  • A recommendation adapted to your property
  • Professional installation without compromise