Wall-Mounted Heat Pump ARCOAIRE 16.8 SEER | 9,000 BTU - R410A
Cool nights in summer, a comfortable bedroom in winter
The bedroom is the room where you notice everything: air that is too cold on the pillow, a unit that kicks back to full power in the middle of the night, the heavy air of July evenings. The Wall-Mounted Heat Pump ARCOAIRE 16.8 SEER | 9,000 BTU - R410A is made for a single closed room: bedroom, office or finished basement. Its variable-speed compressor follows that room's demand closely, without the on-off cycles that chill the walls and then overheat the air.
Its certified ratings are 18.5 SEER2, 10.5 EER2 and 8.8 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2415674. The series name carries the mention 16.8 SEER; to compare units with one another, it is the SEER2 rating on the certificate that counts, and for this pairing it is 18.5.
The right size for a closed room
The common reflex is to buy bigger "to be safe." In a bedroom, the opposite gives the best comfort. An oversized unit reaches the set point in a few minutes, stops, then starts again: the air is cold but stays damp, and the temperature rises and falls in waves. A nominal capacity of 9,000 BTU/h suits a bedroom of ordinary size, a home office or a small basement room in a reasonably insulated house.
Some situations still call for a closer look: a bedroom under the roof that heats up in the afternoon sun, a room with large west-facing windows, a poorly insulated exterior wall, or a door that always stays open onto a hallway. In those cases, we measure the room, look at the windows and insulation, and tell you plainly whether this size is enough or whether you should go up one step.
A compressor that slows down instead of stopping
A wall-mounted heat pump does not make heat the way a baseboard does: it moves it. In winter, the refrigerant captures the heat contained in the outdoor air, even when it is cold, then the compressor concentrates it and the indoor unit releases it into the room. In summer, a valve reverses the circuit and the bedroom's heat is rejected outside. It is this transfer, rather than an electric resistance, that delivers more heating energy than the electricity consumed.
Inverter technology adds one essential thing: the compressor changes speed instead of running all-or-nothing. As the bedroom approaches the set point, it slows down and keeps turning gently. The temperature stays stable, cold starts are rare, and the unit spends most of its time at low speed, where it works most efficiently. The circuit uses R-410A refrigerant, a proven fluid that refrigeration technicians know well, which keeps maintenance and service simple over the years.
Sleeping without a draft
Where the indoor unit goes matters as much for comfort as the unit itself. We avoid placing the head above the bed or facing the pillow: the airflow should sweep the room and return to the unit, not fall on the sleeper. Most often, the wall opposite the bed or a side wall, mounted high, gives the best circulation. The adjustable louvres then let you aim the air toward the ceiling in cooling and toward the floor in heating.
At night, a variable-speed heat pump has another advantage: once the room is at the right temperature, it only needs a low airflow to hold it there. No abrupt restart in the middle of the night, no fan that ramps up and down at regular intervals. For a home office, the same logic applies during the day: a stable room, with no afternoon heat spike when the computer and the sun add up.
What the certificate publishes for winter
For heating, we only report the points that were measured and published. The certificate lists 6,400 BTU/h at -8 °C (17 °F), about 71% of nominal capacity, and 7,100 BTU/h at -15 °C (5 °F), about 79%, with a COP of 2.10 at that last point. The two points are measured separately; we report each one as published, even though the -15 °C value is higher than the -8 °C value.
In practice, in a well-insulated bedroom, this unit handles most of the heating for most of the winter. On the coldest January nights, the existing baseboard remains a useful backup: set its thermostat a few degrees below the heat pump's, and it only steps in when the room truly needs it. The ENERGY STAR cold-climate designation confirms that the pairing was evaluated for these kinds of conditions.
Cooling and drier air in July
In summer, the nominal cooling capacity is 9,000 BTU/h. The 10.5 EER2 rating measures efficiency on a hot day, when demand is at its highest; the SEER2 rating covers the whole season. For a bedroom, the issue is not only temperature but humidity: air at the right temperature but muggy still keeps you from sleeping well.
This is where a properly sized unit makes the difference. By running long at low speed, the indoor coil stays cold and condenses moisture from the air, which then flows out through the drain. Dehumidification therefore happens continuously, without you having to lower the set point. An oversized heat pump, by contrast, cools quickly and stops before it has dried the air.
Reading the ratings without jargon
- SEER2 (18.5): cooling efficiency over a full season. The higher the number, the less electricity it takes for the same cooling.
- EER2 (10.5): cooling efficiency in hot weather, at the point of highest demand.
- HSPF2 (8.8): heating efficiency over a season. This is the rating that weighs most on the winter bill in Quebec.
- COP (2.10 at -15 °C): the amount of heat delivered for each unit of electricity consumed, at a given temperature. An electric baseboard delivers one unit of heat for one unit of electricity.
These figures come from certificate AHRI 205967968, as published by ENERGY STAR.
LogisVert
This pairing does not carry an amount on Hydro-Québec's LogisVert list of October 19, 2026. If the grant matters for your project, we will point you to an eligible pairing of comparable size and show you both options side by side in the quote.
Installed by AirGreen, from the visit to commissioning
The visit and choosing the location
Everything starts with a home visit. We measure the room, note the orientation of the windows and the condition of the insulation, then run an on-site assessment to confirm the capacity is right. This is also when we choose, with you, the wall for the indoor unit and the location of the outdoor unit.
The indoor unit is secured to the framing, where the airflow covers the room, with a drainage slope for condensate. The outdoor unit goes on a ground or wall stand, above the snow line, sheltered from snow sliding off roofs and away from bedroom windows, including the neighbours'.
Refrigerant lines, drain and dedicated circuit
The refrigerant lines, the communication cable and the drain go through a single opening in the wall, sealed inside and out. A line cover can finish the run on the exterior wall for a clean look. The drain is routed so that condensate flows freely in summer and does not freeze in front of a door or a walkway in winter.
The system needs a dedicated circuit at the electrical panel, with a disconnect near the outdoor unit: we check the panel capacity during the visit. At commissioning, the refrigerant circuit is evacuated and checked for tightness before the valves are opened, then we test heating, cooling and drain flow, and show you how to use the remote control.
Maintaining a bedroom heat pump
Rinse the indoor filters every two weeks in season: in a bedroom, dust and textile fibres build up faster than you would think. Keep the outdoor unit clear of snow and leaves, and plan annual HVAC maintenance of the coils, drain and electrical connections. In winter, white vapour during defrost and a short pause in heating are normal. Our cleaning service takes over when you prefer to hand off the annual visit.
AirGreen, for the life of the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.
Request your free estimate for the Wall-Mounted Heat Pump ARCOAIRE 16.8 SEER | 9,000 BTU - R410A. We assess the bedroom or office on site, confirm the right size and give you a written quote before anything is signed.