Electronic Thermostat HONEYWELL TH135-01-B/U | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: TH135-01-B/U

Homes heated by a hot-water boiler have particular needs.

24 Vlow-voltage thermostat
Simpleno app
3 yearsmanufacturer warranty
Get my installed price 514 316-2973

Quick facts

Model numberTH135-01-B/U
ProgrammableNo
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty3 years

Homes heated by a hot-water boiler have particular needs. Water stores heat and releases it slowly, which calls for patient regulation, and the circulator pump can sit idle all summer. The Honeywell TH135-01-B/U, from the Aube line, takes these realities into account. This non-programmable electronic thermostat controls heating only on 24 V low-voltage, millivolt and hot-water (hydronic) systems. It offers three presets, Comfort, Economy and Vacation, pump protection and a choice of two regulation modes. Its 79 x 79 mm square housing is one of the most compact in our selection.

A compact thermostat designed for hot water

The TH135 works on 24 VAC or 24 VDC systems and on millivolt systems. It handles a 5 A resistive or 2 A inductive load. It's powered by two AA alkaline batteries, with a low-battery indicator that warns you 60 days ahead. Its thermistor sensor displays the temperature in 0.1-degree increments, in Celsius or Fahrenheit, and stated accuracy is ±0.5 °C.

Two regulation modes

Regulation is selectable. Adaptive proportional mode adjusts the equipment's operation to keep the temperature close to the setpoint, which suits hot-water systems well. Conventional mode with anticipation reproduces the operation of a traditional thermostat. Cycles can be set to 15 or 20 minutes, or 4 or 3 cycles per hour. Our technicians choose the combination best suited to your boiler or equipment at start-up.

Pump protection

A circulator pump that sits idle for months can seize. The TH135 runs it once every 24 hours, even when no heat is called for. This simple feature helps keep the pump ready for fall. The thermostat also has a remote input for the Aube CT240 telephone controller. It carries CSA certification (CAN/CSA-C828-06).

Technical specifications

  • Stage: 1 heating (heating only)
  • Systems: low-voltage or millivolt central heating, hot-water (hydronic) heating
  • Power: 24 VAC or 24 VDC and millivolt systems; 2 AA alkaline batteries
  • Load: 5 A resistive / 2 A inductive
  • Non-programmable, 3 presets: Comfort, Economy, Vacation
  • Selectable regulation: adaptive proportional or conventional with anticipation
  • Selectable cycles: 15 or 20 minutes (4 or 3 cycles per hour)
  • Pump protection: runs every 24 hours
  • Display: LCD, temperature in 0.1-degree increments; Celsius or Fahrenheit
  • Setting range: 5 to 30 °C (40 to 85 °F); accuracy: ±0.5 °C
  • Low-battery indicator (60-day advance warning)
  • Remote input for Aube CT240 telephone controller
  • Sensor: built-in thermistor; CSA certification (CAN/CSA-C828-06)
  • Connectivity: none
  • Dimensions: 79 x 79 x 22 mm (3.1 x 3.1 x 0.8 in.)
  • Colour: white

Installation and start-up

Replacing a low-voltage thermostat doesn't take long when the wiring is in good shape, but it calls for care. The AirGreen technician shuts off power to the equipment, notes the position of each wire, removes the old control and mounts the new base. The thermostat is then configured for your equipment and each available function is tested. If the existing wires are too short, damaged or poorly labelled, we fix it on the spot. Before leaving, we set the starting setpoint with you and explain how to switch from one mode to another.

The presets day to day

The TH135 has no schedule, but its three presets fill much of that role. Comfort mode is the temperature for when you're home, Economy mode a reduced setpoint for the night or the workday, and Vacation mode a temperature for longer absences. Switching from one to another takes a single button press. It's a simple way to cut heating time without programming anything. The AA batteries power the control; the low-battery indicator leaves you plenty of time to replace them.

Simple energy management

You don't need to program a schedule to manage your heating better. A well-chosen setpoint, held accurately, is already a good starting point. In winter, many households set a comfortable temperature for living areas and a lower one for bedrooms, the basement or rooms where little time is spent. For absences of several days, lowering the setpoint before leaving is still the most cost-effective move. These habits, applied consistently, show up on the bill.

The TH135 next to the TH140-28 and the TH141HC

The TH135-01-B/U, the TH140-28-01-B/U and the TH141HC-28-B/U are three battery-powered electronic controls from the Aube line. The TH135 is non-programmable, with presets, in a compact 79 x 79 mm housing. The TH140-28 is 7-day programmable, with four periods per day, and works from millivolts up to 240 V. The TH141HC adds cooling, with automatic changeover and fan control. For a home heated with hot water, with no air conditioning, that doesn't want a schedule, the TH135 is the most straightforward choice.

Keeping the control reliable

Avoid placing lamps, TVs or furniture right under the thermostat: the heat they give off or the air they block throws off the reading. Clean the surface with a soft, dry cloth. When batteries are installed, change them before winter so a sudden cold snap doesn't catch you off guard. If you notice the heating starting and stopping very often, or not stopping at all, contact us: it may be a cycle setting, a loose wire or a part of the unit that needs checking.

The know-how of a family business

AirGreen grew out of a family of tradespeople and has kept their instincts: do the job right the first time, explain clearly and stay reachable after the installation. For more than 15 years, we have been installing and maintaining heating, cooling and ventilation equipment in homes and businesses in Montréal, Laval, Longueuil, the North Shore and the South Shore. Our RBQ licence governs our work, and our team knows furnaces and heat pumps as well as electric baseboard heaters and floor heating. When we replace a thermostat, we take the opportunity to look over the equipment it controls and point out anything that deserves your attention. Our Boucherville showroom welcomes you if you'd like to compare several models.

To move ahead, write to us or call AirGreen. Our advisors confirm compatibility with your installation, then our technicians install and commission the thermostat at your home in Montréal, Laval, Longueuil, the North Shore or the South Shore.

01 · Key facts

Key facts: HONEYWELL TH135-01-B/U

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

Type24 V thermostatHONEYWELL TH135-01-B/U
Forlow-voltage or millivolt central heating, hot waterSystems
Power24 VAC or 24 VDC and millivolt systemsPower supply
ConnectionnoneConnectivity
02 · Compatible?

Is the HONEYWELL TH135-01-B/U compatible with your heating?

Two steps, thirty seconds. The verdict takes your system and your wiring into account.

Full compatibility table

Heating systemVerdictWhy
Central heat pumpDepends on the modelDepends on the number of stages: see the spec sheet below.
Dual energy (heat pump + furnace)Depends on the modelDepends on the model: dual energy needs backup-heat control. See the spec sheet.
Electric furnaceYes24 V control of the furnace.
Gas or oil furnaceYes24 V control of the furnace; the thermostat does not touch the fuel supply.
Steam, gravity or hot waterYesThe spec sheet lists hot water or hydronic systems.
Baseboards, convectors, radiant ceilingNoA baseboard runs on 120/240 V: it needs a line-voltage electronic thermostat.
Fan-forced heaterNoA fan-forced heater needs a line-voltage thermostat rated for fans.
Electric floor heatingNoElectric floor heating needs a floor thermostat with a probe.
Wall or ducted mini-split heat pumpNoA wall heat pump is controlled by its own brand’s controller or a compatible Wi-Fi module.
03 · Wiring

The terminals behind the thermostat

Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.

04 · Try it

Try the HONEYWELL TH135-01-B/U before you buy

Raise the setpoint, change the mode: see how it responds.

05 · Winter and rebates

Winter, Rate Flex D and rebates: what this thermostat changes

With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. Turning the setpoint down a few degrees during those hours is what counts.

06 · Head to head

The HONEYWELL TH135-01-B/U or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

07 · The right choice

The right thermostat in three questions

If this model is not the right one for you, the page says so and shows you which one is.

08 · The system

Products that go with the HONEYWELL TH135-01-B/U

Parts named in its spec sheet that we sell and install.

09 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01InspectionEquipment, stages to control and existing wiring.
  2. 02C wireCommon wire added if the model needs it and it is missing.
  3. 03MountingWall base, terminal wiring, cover plate if needed.
  4. 04SettingsEquipment type, stages, dual energy and accessories.
  5. 05Start-upConnection, app, schedule and tests with you.
10 · Specifications

HONEYWELL TH135-01-B/U specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralStage1 heat (heat only)
GeneralSystemslow-voltage or millivolt central heating, hot water (hydronic) heating
ElectricalPower supply24 VAC or 24 VDC and millivolt systems; 2 AA alkaline batteries
ElectricalLoad5 A resistive / 2 A inductive
GeneralNon-programmable, 3 presetsComfort, Economy, Vacation
GeneralSelectable controladaptive proportional or conventional with anticipation
GeneralSelectable cycles15 or 20 minutes (4 or 3 cycles per hour)
ElectricalPump protectionturns on every 24 hours
Format and contentsDisplayLCD, temperature in 0.1-degree increments; Celsius or Fahrenheit
GeneralAdjustment range5 to 30 °C (40 to 85 °F); accuracy: ±0.5 °C
GeneralOtherLow battery indicator (60-day advance warning)
GeneralOtherRemote input for Aube CT240 telephone controller
GeneralProbebuilt-in thermistor; CSA certification (CAN/CSA-C828-06)
ConnectivityConnectivitynone
Format and contentsDimensions79 x 79 x 22 mm (3.1 x 3.1 x 0.8 in.)
Format and contentsColourwhite
11 · Questions

Frequently asked questions about the HONEYWELL TH135-01-B/U

Short answers, no detours.

What does the HONEYWELL TH135-01-B/U work with?

According to the manufacturer’s sheet: low-voltage or millivolt central heating, hot water (hydronic) heating.

Does it need a C wire?

Per the spec sheet, it can run on batteries; a common wire is still recommended when available.

Can it control electric baseboards?

No. It is a low-voltage (24 V) thermostat. 120/240 V baseboards need a line-voltage electronic thermostat.

Can it be controlled remotely?

Not directly: it has no built-in Wi-Fi.

What is the warranty?

3 years, per the manufacturer’s information.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.