Heat pump with backup or two-stage furnace: a 5-1-1 schedule that keeps Saturday and Sunday apart, plus an L terminal for heat pump diagnostics.

2/2 or 2/1conventional or heat pump
7 to 37 °Csetpoint range
5 yearsmanufacturer warranty
Programmable
Get my installed price 514 316-2973

Quick facts

Model number1F85U-22PR
ProgrammableYes
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty5 years

Saturday is for sleeping in; Sunday starts early at the hockey rink. In 5-1-1 mode, the 80 Series 1F85U-22PR (EMERSON’s White-Rodgers line) gives each of those days its own schedule. It suits a central heat pump with backup heat as well as a two-stage furnace paired with an air conditioner.

What it runs, day to day

  • On a heat pump with backup: 2 heat stages and 1 cool stage at most.
  • Conventional system: up to 2 heat and 2 cool stages on gas, oil or electric equipment, 24 V or millivolt.
  • L terminal: provided for heat pump diagnostics.
  • Schedule: 7-day or 5-1-1 (default) programming, or non-programmable, with 4 periods per day.
  • High-contrast screen: 5 sq. in. and backlit, easy to read in a dim hallway.
  • Everyday controls: auto changeover, filter reminder, keypad lock and setpoint limits within a 7 to 37 °C range.

Furnace or heat pump: what fits

Gas, oil and electric furnaces and central heat pumps with backup heat are its home ground. The manufacturer’s instructions also name 3-wire hydronic zone valves. The manufacturer’s documents do not provide dual-fuel control for this model, though, and it is not for baseboards, convectors, radiant ceilings, fan-forced heaters, electric floor heating, or wall or ducted heat pumps.

22PR, 42PR or 22NP?

The EMERSON 80 Series 1F85U-42PR keeps the same schedule but goes up to 4 heat and 2 cool stages on a heat pump, so it is the one to choose if your heat pump calls for more than 2 heat stages. The EMERSON 80 Series 1F85U-22NP runs the same stages as the 1F85U-22PR with no schedule at all. All three accept batteries or a C wire.

Installation and setup by AirGreen

The technician reads the existing wiring and picks the power source: the C wire if there is one, batteries if not. They set the 1F85U-22PR up as a heat pump with backup or as a two-stage conventional system, connect the L terminal if your heat pump supports it, then program your weekdays, your Saturday and your Sunday. These settings are planned with you during the free in-home estimate, before any work.

Manufacturer document: 1F85U-22PR installation instructions (37-7555). Sold and installed by AirGreen. We serve Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · Key facts

Key facts: EMERSON 80 Series 1F85U-22PR

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

Type24 V thermostatEMERSON 80 Series 1F85U-22PR
Forgas, oil or electricSystems
Powerbatteries: mV to 30 VACPower supply
ConnectionnoneConnectivity
02 · Compatible?

Is the EMERSON 80 Series 1F85U-22PR compatible with your heating?

Two steps, thirty seconds. The verdict takes your system and your wiring into account.

Full compatibility table

Heating systemVerdictWhy
Central heat pumpYesHandles heat pumps (2H/1C per the spec sheet).
Dual energy (heat pump + furnace)NoThe manufacturer’s documents do not provide dual-energy control for this model.
Electric furnaceYes24 V control of the furnace.
Gas or oil furnaceYes24 V control of the furnace; the thermostat does not touch the fuel supply.
Steam, gravity or hot waterYesThe brand’s documents cover 3-wire hydronic zone valves.
Baseboards, convectors, radiant ceilingNoA baseboard runs on 120/240 V: it needs a line-voltage electronic thermostat.
Fan-forced heaterNoA fan-forced heater needs a line-voltage thermostat rated for fans.
Electric floor heatingNoElectric floor heating needs a floor thermostat with a probe.
Wall or ducted mini-split heat pumpNoA wall heat pump is controlled by its own brand’s controller or a compatible Wi-Fi module.
03 · Wiring

The terminals behind the thermostat

Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.

04 · Try it

Try the EMERSON 80 Series 1F85U-22PR before you buy

Raise the setpoint, change the mode: see how it responds.

05 · Your savings

How much good programming can save you

Set up your typical week. The math follows the rule published by Natural Resources Canada.

06 · Winter and rebates

Winter, Rate Flex D and rebates: what this thermostat changes

With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. A programmable thermostat does the work for you.

07 · Head to head

The EMERSON 80 Series 1F85U-22PR or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

08 · The right choice

The right thermostat in three questions

If this model is not the right one for you, the page says so and shows you which one is.

09 · The system

Products that go with the EMERSON 80 Series 1F85U-22PR

Parts named in its spec sheet that we sell and install.

10 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01InspectionEquipment, stages to control and existing wiring.
  2. 02C wireCommon wire added if the model needs it and it is missing.
  3. 03MountingWall base, terminal wiring, cover plate if needed.
  4. 04SettingsEquipment type, stages, dual energy and accessories.
  5. 05Start-upConnection, app, schedule and tests with you.
11 · Specifications

EMERSON 80 Series 1F85U-22PR specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralStagesconventional: up to 2 heat / 2 cool; heat pump: up to 2 heat / 1 cool
GeneralSystemsgas, oil or electric (millivolt and 24 V); heat pump with backup; 3-wire hydronic zone valves
GeneralProgramming7-day, 5-1-1 (default) or non-programmable; 4 periods per day
ElectricalPower supplybatteries: mV to 30 VAC; hardwired: 20 to 30 VAC (C wire)
ElectricalTerminalsRC, RH, C, W/E, W2, Y, Y2, G, O/B, 6, L
GeneralSetpoint range7 to 37 °C (45 to 99 °F)
GeneralFeaturesauto changeover, heat pump diagnostic L terminal, keypad lock, setpoint limits, filter reminder, display adjustment
Format and contentsDisplay5 sq. in. high-contrast backlit display
ConnectivityConnectivitynone (no Wi-Fi)
Format and contentsDimensions3-3/4 in. (H) x 6 in. (W) x 1-1/8 in. (D)
Format and contentsWall plateoptional F61-2663, 6-3/4 x 4-1/2 in., to cover marks left by the old thermostat
GeneralManufacturer instructions37-7555 (White-Rodgers)
12 · Questions

Frequently asked questions about the EMERSON 80 Series 1F85U-22PR

Short answers, no detours.

What does the EMERSON 80 Series 1F85U-22PR work with?

According to the manufacturer’s sheet: gas, oil or electric (millivolt and 24 V); heat pump with backup; 3-wire hydronic zone valves.

Does it need a C wire?

Per the spec sheet, it can run on batteries; a common wire is still recommended when available.

Can it control electric baseboards?

No. It is a low-voltage (24 V) thermostat. 120/240 V baseboards need a line-voltage electronic thermostat.

Can it be controlled remotely?

Not directly: it has no built-in Wi-Fi.

What is the warranty?

5 years, per the manufacturer’s information.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.