KINGHOME Multi-Zone R32 Floor-Ceiling Unit | 12,000 BTU
The floor-ceiling format for finished basements, meeting rooms and professional offices
A finished basement with a drywall ceiling, walls lined with storage and a single basement window on the outside wall: that's one of the situations where we most often install the KINGHOME 12,000 BTU floor-ceiling unit. The same format works in small-business meeting rooms, professional offices on the ground floor of a building in Laval or Longueuil, and daycare classrooms, where the walls are taken and the ceiling isn't suspended.
This unit is an indoor head for a multi-zone heat pump. It doesn't work on its own: it has to be connected to a KINGHOME Ultra Heat outdoor unit, which supplies it with R-32 refrigerant and power. It has no AHRI certification of its own; the certified efficiency is that of the complete system.
Why a floor-ceiling unit rather than a cassette in the basement
A cassette needs a suspended ceiling and clearance above it. In a basement finished with drywall, installing one means opening the ceiling, redoing part of the finish and working around the joists, plumbing pipes and wiring already in place. The floor-ceiling unit mounts under the existing ceiling, without touching the finish, and blows air horizontally along the full length of the room.
It can also be installed low on a wall, like a console. In a basement, that position sends warm air at floor level, right where the concrete slab cools the room in winter. We choose the position with you based on how the room is used: family room, office, exercise room.
The specs of the 12,000 BTU model
- Nominal capacity: 12,000 BTU, R-32 refrigerant
- Maximum airflow: 412 CFM
- Indoor sound level: 29 to 39 dB(A)
- Dehumidification: 2.96 pt/h, or about 1.4 L/h
- Dimensions: 34.37 x 9.25 x 26.18 inches (width x depth x height)
- 220 V power supplied by the outdoor unit
- Wi-Fi: optional
The most useful number for a basement is the 2.96 pt/h of dehumidification. That's almost double the 9,000 BTU model, and it's also more than the published value for the 18,000 BTU model in the same series. For a basement that's damp in summer, or a meeting room that fills up for an hour, the 12,000 BTU is often the best choice in the series, even when the thermal load could leave you torn between two sizes.
The maximum sound level of 39 dB(A), published in the KINGHOME multi-zone brochure, stays low for a meeting room or an office.
Choosing the zone's capacity
The 12,000 BTU suits a medium-sized closed room or one zone of a partitioned basement. For a fully open basement, we do an on-site assessment of heating needs before deciding: the below-grade part of the walls loses less heat than walls above ground, but basement windows and a poorly insulated rim joist lose a lot. Sometimes a well-placed 12,000 BTU is enough where you'd expect an 18,000 BTU, and the reverse happens too.
Compatible Ultra Heat outdoor units
According to the compatibility table in the KINGHOME multi-zone brochure, the 12,000 BTU heads connect to all the outdoor units:
- KM18X6O (up to 2 zones) and KM24X6O (up to 3 zones)
- KM30X6O and KM36X6O (up to 4 zones)
- KM42X6O and KM48X6O (up to 5 zones)
- KM60X6O (up to 6 zones)
In a single-family house, this unit often complements an existing system of wall-mounted heads: the basement is added as an extra zone on a KM30X6O or a KM36X6O, with no second outdoor unit. The KM18X6O to KM48X6O units carry the ENERGY STAR cold climate designation; the KM60X6O doesn't.
Features
The manufacturer's spec sheet lists dehumidification mode, the I-feel function, self-cleaning, forced defrost, soft start, low-voltage start-up and a maintenance heating mode that keeps a space above freezing. The infrared remote is included. Wi-Fi control is added through an optional wired wall controller, which is handy in a meeting room where the remote tends to go missing.
What we check before the installation
Our assessments in Montréal, Laval, Longueuil, on the North Shore and on the South Shore cover the following points for this format.
Ceiling anchoring
In the ceiling position, the unit hangs from the structure on threaded rods. In a basement, we locate the joists and check that no beam, plumbing pipe or duct gets in the way of the mounting or the air outlet. Drywall alone never holds the unit.
The electrical supply
The head gets its 220 V from the outdoor unit. The breaker to plan for is the outdoor unit's, based on the minimum circuit ampacity (MCA) and maximum overcurrent protection (MOP) on its spec sheet. When a zone is added to an existing system, we check that the outdoor unit in place can take one more head.
The outdoor unit
On a wall bracket above the snow, with clearance for the defrost water. A unit set on the ground at the height of the basement window ends up buried in snow and also blocks the light: we avoid that.
The piping
The connection diameters follow the manufacturer's spec sheet. In the basement, the piping often goes through the rim joist: we seal and insulate the penetration so it doesn't create a new cold-air leak.
The drain
The condensate has to drain by gravity to a floor drain or a standpipe. In the basement, draining all the way outside is rarely possible: we connect to the nearest standpipe or add a condensate pump.
LogisVert assistance
This head has no LogisVert amount on its own, since it has no certification of its own. The indicative LogisVert amount is tied to the complete residential system, outdoor unit and head combination, and is calculated using the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C, or $50 with the KM60X6O, which has no cold climate designation); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The indicative amount published on each outdoor unit's page corresponds to the certification with wall-mounted heads; we check your combination before the quote.
Why go with AirGreen
- Salaried refrigeration technicians, no subcontracting.
- Civil liability insurance of $5,000,000.
- Kinghome warranty registration done by our team.
- After-sales service you can reach for maintenance and questions.
Ask for your free estimate: we assess the basement or the space, the mounting position and the outdoor unit, and give you a detailed quote.
Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor.