THERMO 2000 VenTum 40 Hydronic Fan Coil

In stock

Thermo 2000’s VenTum 40 is a multi-position hydronic fan coil: ECM fan, built-in circulator and hot-water coil, up to 1,100 CFM.

Model numberVENTUM40

1,100 CFMmaximum airflow
31,900 BTU/h120 °F water, 3 GPM, 1,100 CFM
ECM 1/2 HPfan adjustable in 10 CFM steps
120 V · single phaseVertical or horizontalOptional cooling coilThermostat not included
Series
Up to 1,100 CFMUp to 2,000 CFM
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberVENTUM40
ManufacturerThermo 2000
Max. airflow1,100 CFM
FanECM, 1/2 HP, 120 V
CirculatorBuilt-in, 3 speeds
Water connections3/4 in copper, soldered
Filter16 x 20 x 1 in

Hot water in the loop, warm air in the ducts

The Thermo 2000 VenTum 40 hydronic fan coil links a hot-water heating system to a duct network. It takes hot water from a closed loop, circulates it through a 4-row copper coil and blows the heated air into the house, up to 1,100 CFM. The 1/2 HP ECM fan, the built-in 3-speed circulator and the digital controller are housed in the same cabinet.

Who the VenTum 40 is for

It suits homes that already have ductwork and that heat, or want to heat, with an electric boiler or an air-to-water heat pump. You keep forced-air distribution, but the heat comes from water. The front controller displays the unit’s status, temperatures and alarm codes. It manages 2 zones, offers separate airflow settings for heating, cooling, ventilation and dehumidification, a BOOST mode and an anti-freeze function that takes over if the house thermostat fails.

Reading the capacity table for your source

The heat delivered depends mainly on the water temperature. Thermo 2000 publishes a full table, with return air at 70 °F (21 °C). At 3 GPM and between 700 and 1,100 CFM, the VenTum 40 delivers 13,400 to 17,500 BTU/h with 100 °F water, 24,400 to 31,900 BTU/h at 120 °F and 47,400 to 63,200 BTU/h at 160 °F. An air-to-water heat pump often works at the low end of this table, while an electric boiler can aim higher. That is why we size the unit with your source’s actual water temperature, not with the highest figure on the sheet.

For summer, an air conditioner or heat pump coil can be added as an option, with an outdoor unit. The manufacturer associates 2 tons of cooling with 700 and 800 CFM, and 3 tons with 900, 1,000 and 1,100 CFM.

Its place in a Quebec home

The VenTum is multi-position: vertical in a basement in Longueuil, horizontal when height is limited in a townhouse in Montreal. The return opening is pre-cut on the right, left or bottom, which simplifies the connection to existing ductwork. It weighs 99 lb, connects to the water through soldered 3/4 in copper fittings and runs on 120 V single phase. The ductwork must stay within a maximum external static pressure of 0.75 in. w.c. The 16 x 20 x 1 in filter slides into the supplied rack.

What AirGreen’s installation includes

We install the VenTum with electric boilers and air-to-water heat pumps, in Laval, on the North Shore, on the South Shore and throughout Greater Montreal: free on-site estimate, written quote, setting the unit, connecting it to the water loop and the ductwork, placing the supplied air temperature sensors, adjusting the airflow and commissioning. The thermostat is not included; we choose it with you. Sold alone, the unit does not qualify for the LogisVert grant.

AirGreen is a family business established in Montreal for more than 15 years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Thermo 2000 warrants all VenTum parts and components for 2 years, under its terms.

Tell us which source supplies your loop and at what temperature: we check whether the VenTum 40 is enough for the house. Free estimate and financing available.

01 · What it is for

Forced-air heating with water from an electric boiler or an air-to-water heat pump

The VenTum 40 takes hot water from a closed loop, runs it through its copper coil and pushes warm air through the home’s ductwork. Its ECM fan and built-in circulator are managed by a front-mounted digital controller.

  • House with existing ductwork heated by an electric boiler
  • Air-to-water heat pump whose heat should be distributed by forced air
  • Basement installation in the vertical position, or horizontal when height is limited
  • Project adding central air conditioning with an optional coil
From 100 to 200 °F13,400 to 17,500 BTU/h with 100 °F water and 68,800 to 89,700 BTU/h at 200 °F (3 GPM, 700 to 1,100 CFM).
Adjustable ECM fanAirflow set in 10 CFM steps, with separate settings for heating, cooling, ventilation and dehumidification.
Multi-positionVertical or horizontal installation, return opening pre-cut on the right, left or bottom.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerThermo 2000
ModelVenTum 40
TypeHydronic fan coil (hot-water air handler), multi-position
Maximum airflow1,100 CFM
Airflow adjustmentIn 10 CFM increments
Max. external static pressure0.75 in. w.c.
FanECM motor, 1/2 HP, 120 V, 60 Hz, single phase; 9 x 6 in wheel
Built-in circulator3 speeds, 1/25 HP, 120 V; limits 200 °F (93 °C), 145 psi (1000 kPa)
Coil4 rows, 3/8 x 0.014 in copper tubes (ASTM B88), 14 fins/in, 15 x 18 x 3.5 in
Water connections3/4 in copper, soldered
Pressure drop4.5 psi at 5 GPM
Maximum water pressure150 psi
Maximum water temperature200 °F (93 °C)
Water temperature range50 to 200 °F
FluidWater, or propylene glycol up to 50%
Heating, 100 °F water13,400 to 17,500 BTU/h at 3 GPM; 16,400 to 21,700 BTU/h at 5 GPM
Heating, 120 °F water24,400 to 31,900 BTU/h at 3 GPM; 27,200 to 37,700 BTU/h at 5 GPM
Heating, 140 °F water35,500 to 46,400 BTU/h at 3 GPM; 38,500 to 53,200 BTU/h at 5 GPM
Heating, 160 °F water47,400 to 63,200 BTU/h at 3 GPM; 49,700 to 68,200 BTU/h at 5 GPM
Heating, 180 °F water50,600 to 68,100 BTU/h at 3 GPM; 60,200 to 87,400 BTU/h at 5 GPM
Heating, 200 °F water68,800 to 89,700 BTU/h at 3 GPM; 72,000 to 100,400 BTU/h at 5 GPM
Rating conditionsReturn air at 70 °F (21 °C), airflow from 700 to 1,100 CFM
Cooling (optional coil)2 tons at 700 and 800 CFM; 3 tons at 900, 1,000 and 1,100 CFM
ControlsFront digital controller (status, temperatures, alarm codes), 2 zones, BOOST mode, anti-freeze function
Filter16 x 20 x 1 in
Weight99 lb
Manufacturer warranty2 years on all parts and components
Model numberVENTUM40
03 · Before installing

What to know before installing

  • Sold alone, the fan coil does not qualify for the LogisVert grant.
  • The thermostat is not included. The cooling coil is optional and also requires an outdoor unit.
  • Maximum external static pressure of 0.75 in. w.c.: the ductwork must stay within this limit.
  • 120 V, 60 Hz, single-phase power supply for the fan and the circulator.
  • The cabinet dimensions are shown on the drawings in the manufacturer’s manual: we confirm the space on site before ordering.
In the box
  • Filter rack
  • Air temperature sensor(s) to position in the duct
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Hydronic fan coils
See all
Same brand
THERMO 2000
See all
06 · Questions

Frequently asked questions

Does the VenTum 40 work with an air-to-water heat pump?

Yes. The manufacturer’s table starts at 100 °F water. At 120 °F and 3 GPM, it gives 24,400 to 31,900 BTU/h depending on airflow (700 to 1,100 CFM). We calculate the capacity with your source’s actual water temperature.

Can it also provide cooling?

Yes, with an optional air conditioner or heat pump coil and an outdoor unit. Thermo 2000 associates 2 tons with 700 and 800 CFM and 3 tons with 900, 1,000 and 1,100 CFM.

Can it be installed horizontally?

Yes. The VenTum is multi-position: vertical or horizontal, with a return opening pre-cut on the right, left or bottom.

Which filter do I need to buy?

A 16 x 20 x 1 in filter, which slides into the supplied filter rack.

What happens if the thermostat fails?

The VenTum controller has an anti-freeze function that takes over if the house thermostat fails, according to Thermo 2000.

What warranty does Thermo 2000 offer?

Two years on all parts and components of the fan coil, in Canada and the United States. Under the manufacturer’s terms, removal, reinstallation and shipping are paid by the buyer.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A VenTum 40 connected to your hot-water loop by AirGreen