Project

Installation of a Gree Console R32 (indoor system) in Rosemont–La Petite-Patrie

Gree R32 indoor console installed in Rosemont: supply air ≈ 15.3 °C, gravity drain, minimal capping and neat finish. A scalable HVAC solution for condos. AirGreen Service: Montreal, Laval, Longueuil, North Shore, South Shore .

By AirGreen Climatisation & Chauffage Admin7 min read
Installation of a Gree Console R32 (indoor system) in Rosemont–La Petite-Patrie
Installation of a Gree Console R32 (indoor system) in Rosemont–La Petite-Patrie
–chapters in this story
7 minreading time
–type of installation
2025year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

Seamless comfort without encroaching on the walls: our Gree interior console brings immediate and discreet fresh air to a Rosemont condo

Context and objectives of the project

In a modern apartment in Rosemont–La Petite-Patrie , we are working to improve summer and mid-season comfort without compromising the interior aesthetics. The client wants:

  • a compact HVAC solution that does not monopolize wall height,

  • gentle air diffusion in living areas,

  • a clean, fast and easily maintained installation,

  • the possibility of additional heating in autumn/winter with a compatible external compressor.

The Gree R32 indoor console perfectly meets these criteria. It fits into the bottom of the wall, like a modern radiator, while remaining connected to a mini-split outdoor compressor (single or multi-zone) to ensure efficient air conditioning and heating .

Why a Gree R32 indoor console for a Montreal condo?

  • Low installation : ideal under a window or near a load-bearing wall, it frees up the upper wall strip often used for tall furniture, paintings or shelves.

  • Immediate comfort : the front and top blowing distributes the air at occupancy height, limiting the layers of hot air on the ceiling.

  • R-32 efficiency and refrigerant : better seasonal efficiency and reduced charge compared to R-410A.

  • Silence : very low noise levels, adapted to the typical Montreal condo plateau where the rooms are open.

  • Compatibility : The console can be combined with the Gree R32 ranges (single or FreeMatch R32 multi-zone 2 to 5 heads), allowing a wall head to be added later in a bedroom or office.

Study of space and technical choices

The apartment features an open-plan living room with light wood floors, white walls, and a side hallway. Our recommendations:

  • Positioning : bottom of wall, central axis of the living room for uniform diffusion.

  • Seat height : approx. 120–180 mm above the floor to maintain good air intake and facilitate cleaning.

  • Condensate management : gravity drainage via a rear outlet to the outside, ensuring reliability and silence. A pump is not necessary here thanks to the available height difference.

  • Refrigeration path : neat drilling at the rear of the console, discreet exterior cap, minimalist white interior capping for less than 0.5 m. Estimated total length of the refrigeration : 5 to 7 m up to the compressor, in accordance with Gree specifications.

  • Power supply and communication : 14/4 connection between units; main power supply dedicated to the outdoor compressor on a circuit breaker compliant with the Quebec Code, with differential required depending on the configuration.

Installation process (a typical AirGreen day)

  1. Protection of premises : covers, non-slip mats and tarpaulins, confined cutting areas.

  2. Template and anchors : installation of the Gree template, laser level check, anchoring in the structure. Silent blocks to limit micro-vibrations.

  3. Drilling : Core drill inclined outwards for drain gravity ; waterproof jacket inserted; air barrier/vapor barrier foam.

  4. Routing : drawing of insulated copper lines (pre-bent), drain and communication cable; bending radii respected.

  5. Brazing and vacuuming : brazing under nitrogen , deep vacuuming, leak testing, opening of valves.

  6. Commissioning : checking pressures/temperatures, setting the shutters and the setpoint.

  7. Finishes : matching white capping , UV exterior sealing, complete site cleaning.

  8. Skills transfer : explanations of routine maintenance and best practices for use.

Measures and performance observed

When switched on in air conditioning mode, the supply air temperature reaches ≈ 15.3 °C in stabilized mode, confirming efficient heat exchange and consistent sizing for the main room. This delta with the ambient air ensures a rapid feeling, without aggressive air currents thanks to the motorized shutters .

In heating mode, the console takes advantage of its low installation: the hot air rises naturally, providing an enveloping sensation. With a high-performance R-32 compressor, the seasonal COP remains advantageous even at low temperatures.

Aesthetic and acoustic result

  • Integration : The striated white facade and compact format blend in with the condo's refined style.

  • Sound discretion : at Low speed, the hiss is almost inaudible; the Medium level is sufficient for a quick top-up at the end of the afternoon.

  • Daily use : the remote control allows simple scenes (night/day), the dehumidification function improves comfort in heavy weather.

Recommended HVAC maintenance

  • Filters : Light vacuuming every 3–4 weeks during use, washing in warm water if necessary.

  • Battery : seasonal inspection; avoid greasy sprays.

  • Drain : annual purge to prevent odors and overflows.

  • Outdoor unit : 30–45 cm clearance, free defrosting in winter, comfortable cleaning of the fins.

  • Professional maintenance : annual AirGreen visit (checking pressures, probes, tightening, thorough cleaning), guaranteeing performance and longevity.

Grants and Eligibility

Depending on the exterior combination chosen ( high-efficiency R-32 compressor and cold performance), this project may be eligible for provincial/local assistance programs for efficient heat pumps in Greater Montreal . We assist our clients in verifying the required technical data sheet (reference temperatures, HSPF/SEER/SCOP) and preparing supporting documents.

What this solution changes for a Montreal condo

  • Targeted comfort without sacrificing upper walls.

  • Energy savings thanks to R-32 and inverter.

  • Scalability : possibility of adding wall heads in multi-zone (bedrooms/office).

  • Light work : a single drilling, reduced capping , clean site in one day.

Pitfalls to avoid (AirGreen feedback)

  • Height too low : risk of obstruction of the suction; respect the ground clearance.

  • Winding drain path : prefer gravity ; a pump is only necessary if no slope is possible.

  • Excessive refrigerated lengths : they penalize yield; aim for a direct and protected route.

  • Undersizing : a console alone does not replace a central system for an entire home; think multi-zone when the surface area requires it.

  • Neglected maintenance : clogged filters = loss of capacity, noise, overconsumption.

Why AirGreen for your HVAC installation in Montreal, Laval, Longueuil, North Shore and South Shore?

  • Team dedicated to mini-splits and interior systems (console, cassette, ducted ).

  • Control of local constraints (co-ownerships, access, timetables, town planning regulations).

  • Neat finishes : watertight seals, aligned cappings , clean drilling.

  • Complete service : estimate, selection of suitable Gree R32 equipment, installation, HVAC maintenance , and grant support.

Key project data (summary)

  • Location : Rosemont–La Petite-Patrie, Montreal.

  • Type : indoor system – console connected to a mini-split heat pump.

  • Brand : Gree ( R-32 ).

  • Model : Gree Console – R32 range (compatible with single or FreeMatch R32 ).

  • Installation : gravity drain, short refrigeration path (≈ 5–7 m), discreet white capping , commissioning with blowing measured at ≈ 15.3 °C in air conditioning mode.

And after?

We offer an annual maintenance plan to maintain high performance and preserve the manufacturer's warranty. Our team covers the entire Greater Montreal area : Montreal, Laval, Longueuil, North Shore, South Shore . For a similar condo, a Gree R32 interior console offers a convincing balance between discretion, comfort, and efficiency.


Keywords worked on : heat pump , interior system , console , HVAC installation , HVAC maintenance , Montreal , Laval , Longueuil , North Shore , South Shore , Gree R32 , mini-split .

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment