Installation of a GREE FreeMatch R32 MultiZone Heat Pump in Rosemont–La Petite-Patrie
AirGreen installs two MultiZone GREE FreeMatch R32 heat pumps on a flat roof in Rosemont–La Petite-Patrie : four-season comfort, preserved facades, high efficiency and easy maintenance throughout Greater Montreal .
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The article, chapter by chapter
Two multi-zone systems on a flat roof: a clean and efficient solution for a Montreal plex
Project background
At AirGreen , we regularly work on typical Montreal flat-roofed plexes. For this building in Rosemont–La Petite-Patrie , our client wanted to modernize the comfort of two units without encroaching on the interior space or the aesthetics of the facade. We proposed two GREE FreeMatch R32 multi-zone heat pumps , each supplying dedicated wall-mounted heads . The flat-roof installation frees up the facades, simplifies vertical cooling paths and guarantees quiet operation for both occupants and the neighborhood.
Why a GREE FreeMatch R32 MultiZone heat pump here?
-
Flexibility : A single outdoor unit powers 2 to 4 zones per home. Ideal when the rooms to be treated are not adjacent.
-
Performance : R-32 technology, variable speed compressor, reliable heating in cold weather (extreme cold range adapted to the Montreal climate).
-
Discretion : reduced roof space, low noise level and no ground contact in the yard.
-
Scalability : possibility of adding a zone later if the configuration allows it.
-
Eligibility : performance allowing access to Quebec subsidies and rebates for high-efficiency heat pumps (subject to eligibility and verification of the criteria in force).
Study and preparation: the keys to a sustainable HVAC installation
Before any drilling, we carry out:
-
Roof structure survey (load, slope, vapor barrier, TPO/EPDM membrane).
-
Optimal refrigeration path : from the roof to the interior heads, favoring gravity lines for condensates and compliant curvature radii .
-
Calculation of lengths and refrigerant top-up : for this project, each group has a static height of approximately 6 to 8 m and a total length of 15 to 25 m per system, within the range prescribed by GREE.
-
Electrical management : dedicated circuit breakers, suitable cable section, proximity switches on the roof, and verified grounding.
Installation on flat roof : stability, resistance and serviceability
-
Raised supports : each outdoor unit rests on a galvanized frame fixed on treated wooden pads resting on the membrane, with anti-vibration isolators . This elevation protects the equipment from water accumulation and snow overflow.
-
Protected routing : UV- insulated refrigeration lines , high-climate black sheaths, communication cables fixed on straight paths along the pads to avoid any pinch points.
-
Clearances : compliance with air supply and return distances, with a service corridor for maintenance.
-
Thaw management : free drainage of defrost water, with natural slope towards the roof outlets.
Crossings and finishes: impeccable sealing
-
Sleeves and flashings : vertical crossings via technical chimneys with membrane-compatible sealing collars .
-
Vapor barrier reconstituted and puttying according to the rules of the art to prevent any infiltration.
-
Discreet white interior capping ** in common areas, ensuring a clean and easily accessible result for maintenance.
Interior: room-by-room comfort
-
High efficiency wall heads , motorized shutters and multi-layer filtration .
-
Precise positioning : clearing obstacles, directing the flow to avoid drafts in living areas and optimizing thermal comfort .
-
Condensates : gravity towards the sanitary columns when the slope allows; compact lifting pump as backup in areas with level constraints.
-
Silence : reduced noise levels, an essential asset for bedrooms and offices.
Sizing: BTU and load coverage
-
Typical envelope profile of a brick plex with white roof: moderate solar gains , infiltration losses controlled after caulking.
-
Selection of 9k to 24k BTU capacities per zone depending on the surface area and orientation, combined with a FreeMatch R32 outdoor unit sized to operate without over-revving during winter peaks at −20 to −25°C .
-
Superheat and subcooling finely tuned during commissioning to maximize SEER/HSPF .
Installation process: fast, clean, secure
-
Site protection (mats, tarpaulins, roof markings).
-
Installation and fixing of the frames.
-
Installation of refrigeration connections on dedicated paths, controlled bending.
-
Nitrogen brazed welds , high pressure nitrogen test .
-
High vacuum < 500 microns, stabilized leak test.
-
Electrical connections and grounding .
-
Recharging if necessary, commissioning and calibration of remote controls.
-
Occupant training : winter/summer usage, filter maintenance, economy settings.
Result: comfort, savings and preserved aesthetics
-
Efficient heating in mid-season and winter, gentle air conditioning in summer.
-
Reduced energy consumption compared to portable devices and old resistance systems.
-
Preserved facades : no unit on the front wall, no footprint.
-
Noise pollution contained for immediate neighbors.
HVAC Maintenance and Best Practices for Longevity
-
Cleaning filters : every 4 to 6 weeks depending on use.
-
Annual inspection : pressures, subcooling, terminal tightening, defrost drain, condition of UV insulation.
-
Snow clearance : Maintain clear space around flat roof units after heavy snowfall.
-
Programming : maintain a stable setpoint deviation to avoid short cycles.
-
Air quality : consider an air exchanger if the airtightness of the accommodation has been improved (controlled supply of fresh air).
Points of attention and pitfalls to avoid
-
Undersized areas: leads to long cycles and discomfort. A load calculation is essential, even for modest areas.
-
Poorly sealed penetrations : source of moisture infiltration and odors. Always entrust flashing to a team trained in TPO/EPDM roofing.
-
Too winding a route : increases pressure losses and reduces efficiency. Favor straight paths and gentle bends.
-
Lack of proximity switch : electrical non-compliance and maintenance inconvenience. We install it systematically.
Grants and funding
High-efficiency heat pumps like the GREE FreeMatch R32 are generally eligible for support programs in Quebec . We assist our customers in verifying criteria , documentation and submitting files. This assistance simplifies access to the savings offered in Greater Montreal (Montreal, Laval , Longueuil , North Shore , South Shore ).
Delay and coordination in a populated environment
Our plex construction sites are planned to limit interruptions : delivery by slot, passages in protected common areas, contained noise, and commissioning on the same day when conditions permit. Coordination with co-owners and tenants is part of our method .
Ready for four-season comfort in your Montreal plex?
We design, install, and maintain multi-zone heat pumps adapted to local buildings. Our team is familiar with flat roofs , vertical runs , and the waterproofing requirements specific to buildings in Rosemont , Plateau , Villeray , LaSalle , and the Southwest . Let's talk about your project.
Project summary technical sheet
-
Type : Multi-Zone heat pump (mini-split)
-
Brand/Range : GREE FreeMatch R32
-
Installation : flat roof on raised frames with insulators
-
Route : vertical roof → housing, UV insulated lines; sealed crossings
-
Estimated lengths : 15–25 m per system; static height 6–8 m
-
Electricity : dedicated circuits, proximity switches on the roof
-
Maintenance : clear access, free defrosting, washable interior filters
SEO keywords : heat pump , multi-zone heat pump , HVAC installation , HVAC maintenance , Montreal , Laval , Longueuil , North Shore , South Shore , GREE FreeMatch R32 , flat roof , Rosemont–La Petite-Patrie .
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).