Job sheet · Project

Installation of a Gree R32 wall-mounted heat pump in Chomedey

In Chomedey, AirGreen installs a Gree R32 wall-mounted heat pump on a brick facade: galvanized brackets, discreet trunking, leak testing, and professional commissioning. HVAC service Montreal, Laval, Longueuil, North Shore, South Shore.

By AirGreen Climatisation & Chauffage Admin6 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
6 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

The full story

The article, chapter by chapter

A clean and durable upgrade on a Laval brick facade

At AirGreen , we modernize the comfort of a home in Chomedey with a Gree R32 wall-mounted heat pump . The goal is clear: to provide precise air conditioning in summer, efficient heating support in winter, and an HVAC system that blends discreetly into the light brick architecture typical of Laval 's residential neighborhoods.

What we put in place for an impeccable result

Our intervention is based around a coherent set of technical elements which ensure performance, longevity and aesthetics.

Selected device and sizing logic

  • Type : single-zone inverter wall-mounted heat pump .

  • Brand / generation : Gree – R32 (A2L) range , renowned for its high efficiency and reliability.

  • Typical capacities : 9,000 to 18,000 BTU for standard living spaces; we size according to the envelope (insulation, glazing), solar orientation and actual use of the room.

  • Refrigerant : R-32 (A2L) , with lower global warming potential than older generations, contributing to a more responsible approach.

Architectural integration and support

  • Support : galvanized wall brackets with high lever arm, fixed in the masonry by means of dimensioned mechanical anchors; internal counterplate when the configuration of the wall requires it.

  • Anti-vibration : elastomer pads under the condenser frame to prevent the transmission of micro-vibrations to the brick and joists of the adjoining terrace.

  • Installation height : raised to clear snow on the ground, secure maintenance and maintain optimal clearances around the facade fan.

Refrigeration and finishing

  • Short rear exit with outward sloping penetration to protect masonry from water.

  • Covering : vertical beige trunking matching the brick and exterior lighting; clip-on corners and covers for a clean finish and easy maintenance access.

  • Nitrogen brazing of the copper connections, leak testing with dry nitrogen, then high vacuum controlled with a digital vacuum gauge to guarantee a minimal residual humidity level .

  • Insulation : High density anti-UV sleeves on refrigerant lines, glued joints to prevent condensation and losses.

Condensates and electricity

  • Drainage : Gravity drainage prioritized—continuous slope, anti-drip loop and discreet outlet; compact pump only if required by internal geometry.

  • Power : Dedicated line from panel, breaker rated at unit current rating, external disconnect switch when required by code and route; UV cable in trunking for maximum protection.


Blowing quality and defrost management

The front-mounted condenser blows freely forward: we scrupulously respect the lateral and frontal clearances to avoid any air recirculation , a frequent cause of reduced efficiency and defrost cycles too close together in heating mode. The inverter unit modulates the speed of the compressor and the fan to stabilize the interior temperature, reduce jolts and lower the noise level.

What the owner earns on a daily basis

  • 4-season comfort : rapid cooling, effective dehumidification mode during heat waves and efficient heat supply when temperatures drop.

  • Energy efficiency : inverter technology and R-32 improve the seasonal energy ratio while reducing the environmental footprint.

  • Controlled silence : anti-vibration support and careful installation prevent resonances against the brick and woodwork.

  • Easy HVAC maintenance : accessible chute, clearances provided for washing the condenser and periodic cleaning of the indoor head filters.


Key steps of our AirGreen method

  1. Audit and load calculation : survey of surfaces, thermal bridges, solar gains and usage profiles.

  2. Installation : sizing of the holes, checking of the carriers, choice of the useful height for the condenser and the passage of the chute.

  3. Brazing / testing : nitrogen , test pressure, high vacuum , stabilization, then opening of the fluid in accordance with the manufacturer's rules.

  4. Commissioning : air flow parameters, flap angle, condensate test, measurement of supply/return intensity and temperature.

  5. Delivery : instructions for use (set temperature, programming, maintenance), technical sheet and installation register useful for guarantees and subsidies .


Special features of a brick facade in Chomedey

Light brick houses with patio doors require special attention:

  • Clean drilling and sealing : masonry-compatible elastomeric sealant, interior vapor barrier to prevent any moisture migration.

  • Water management : do not drain condensate near the patio door; we create an outlet away from traffic and freezing zones.

  • Nighttime noise : adjust silent modes and check the attachments of nearby railings or light fixtures to eliminate resonances.

  • Snow and ice : installation height calculated to remain clear; if the home is very exposed, a snow guard or deflector may be added.


Recommended maintenance: maintaining performance

  • Annual : washing the condenser (fins), checking pressures/probes, testing the condensate pump if present, tightening electrical connections, inspecting insulation and chute covers.

  • Seasonal : dusting of internal filters, visual inspection of clearances and water path.

  • Good reflex : keep the setpoint stable and avoid extreme back and forth between cold/heat modes.


Grants and Eligibility

High-performance R-32 generation wall-mounted heat pumps are generally eligible for assistance programs in Quebec. Our team guides owners in putting together the file (proof of purchase, certificate of compliant installation, manufacturer's performance statements) to maximize the amounts when the criteria are met. We support our clients in Montreal , Laval , Longueuil , North Shore and South Shore .


Common pitfalls avoided by our team

  • Oversizing leading to short cycles and poorly controlled humidity.

  • Air recirculation between facade and obstacles (walls, fences, patio furniture).

  • Poor management of condensates leaving traces on the brick or freezing in winter.

  • Drillings without slope promoting infiltration.

  • Poorly closed chutes that age prematurely in the sun and frost.


Why AirGreen for your next project in Laval

Our value lies in precise diagnosis , careful implementation and follow-up . We combine aesthetics , performance and regulatory compliance for installations that last over time. Whether for a plex, a condominium or a single-family home, we adapt the wall-mounted heat pump to your reality: volumes to be treated, facade constraints, noise, maintenance access and budget.

Planning an installation in Laval, Montreal, Longueuil, on the North Shore, or the South Shore? Let's talk about your living space, your savings goals, and your building's requirements: we'll design a custom HVAC solution, ready for Quebec's humid summers and winters.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment