A clean and durable upgrade on a Laval brick facade
At AirGreen , we modernize the comfort of a home in Chomedey with a Gree R32 wall-mounted heat pump . The goal is clear: to provide precise air conditioning in summer, efficient heating support in winter, and an HVAC system that blends discreetly into the light brick architecture typical of Laval 's residential neighborhoods.
What we put in place for an impeccable result
Our intervention is based around a coherent set of technical elements which ensure performance, longevity and aesthetics.
Selected device and sizing logic
-
Type : single-zone inverter wall-mounted heat pump .
-
Brand / generation : Gree – R32 (A2L) range , renowned for its high efficiency and reliability.
-
Typical capacities : 9,000 to 18,000 BTU for standard living spaces; we size according to the envelope (insulation, glazing), solar orientation and actual use of the room.
-
Refrigerant : R-32 (A2L) , with lower global warming potential than older generations, contributing to a more responsible approach.
Architectural integration and support
-
Support : galvanized wall brackets with high lever arm, fixed in the masonry by means of dimensioned mechanical anchors; internal counterplate when the configuration of the wall requires it.
-
Anti-vibration : elastomer pads under the condenser frame to prevent the transmission of micro-vibrations to the brick and joists of the adjoining terrace.
-
Installation height : raised to clear snow on the ground, secure maintenance and maintain optimal clearances around the facade fan.
Refrigeration and finishing
-
Short rear exit with outward sloping penetration to protect masonry from water.
-
Covering : vertical beige trunking matching the brick and exterior lighting; clip-on corners and covers for a clean finish and easy maintenance access.
-
Nitrogen brazing of the copper connections, leak testing with dry nitrogen, then high vacuum controlled with a digital vacuum gauge to guarantee a minimal residual humidity level .
-
Insulation : High density anti-UV sleeves on refrigerant lines, glued joints to prevent condensation and losses.
Condensates and electricity
-
Drainage : Gravity drainage prioritized—continuous slope, anti-drip loop and discreet outlet; compact pump only if required by internal geometry.
-
Power : Dedicated line from panel, breaker rated at unit current rating, external disconnect switch when required by code and route; UV cable in trunking for maximum protection.
Blowing quality and defrost management
The front-mounted condenser blows freely forward: we scrupulously respect the lateral and frontal clearances to avoid any air recirculation , a frequent cause of reduced efficiency and defrost cycles too close together in heating mode. The inverter unit modulates the speed of the compressor and the fan to stabilize the interior temperature, reduce jolts and lower the noise level.
What the owner earns on a daily basis
-
4-season comfort : rapid cooling, effective dehumidification mode during heat waves and efficient heat supply when temperatures drop.
-
Energy efficiency : inverter technology and R-32 improve the seasonal energy ratio while reducing the environmental footprint.
-
Controlled silence : anti-vibration support and careful installation prevent resonances against the brick and woodwork.
-
Easy HVAC maintenance : accessible chute, clearances provided for washing the condenser and periodic cleaning of the indoor head filters.
Key steps of our AirGreen method
-
Audit and load calculation : survey of surfaces, thermal bridges, solar gains and usage profiles.
-
Installation : sizing of the holes, checking of the carriers, choice of the useful height for the condenser and the passage of the chute.
-
Brazing / testing : nitrogen , test pressure, high vacuum , stabilization, then opening of the fluid in accordance with the manufacturer's rules.
-
Commissioning : air flow parameters, flap angle, condensate test, measurement of supply/return intensity and temperature.
-
Delivery : instructions for use (set temperature, programming, maintenance), technical sheet and installation register useful for guarantees and subsidies .
Special features of a brick facade in Chomedey
Light brick houses with patio doors require special attention:
-
Clean drilling and sealing : masonry-compatible elastomeric sealant, interior vapor barrier to prevent any moisture migration.
-
Water management : do not drain condensate near the patio door; we create an outlet away from traffic and freezing zones.
-
Nighttime noise : adjust silent modes and check the attachments of nearby railings or light fixtures to eliminate resonances.
-
Snow and ice : installation height calculated to remain clear; if the home is very exposed, a snow guard or deflector may be added.
Recommended maintenance: maintaining performance
-
Annual : washing the condenser (fins), checking pressures/probes, testing the condensate pump if present, tightening electrical connections, inspecting insulation and chute covers.
-
Seasonal : dusting of internal filters, visual inspection of clearances and water path.
-
Good reflex : keep the setpoint stable and avoid extreme back and forth between cold/heat modes.
Grants and Eligibility
High-performance R-32 generation wall-mounted heat pumps are generally eligible for assistance programs in Quebec. Our team guides owners in putting together the file (proof of purchase, certificate of compliant installation, manufacturer's performance statements) to maximize the amounts when the criteria are met. We support our clients in Montreal , Laval , Longueuil , North Shore and South Shore .
Common pitfalls avoided by our team
-
Oversizing leading to short cycles and poorly controlled humidity.
-
Air recirculation between facade and obstacles (walls, fences, patio furniture).
-
Poor management of condensates leaving traces on the brick or freezing in winter.
-
Drillings without slope promoting infiltration.
-
Poorly closed chutes that age prematurely in the sun and frost.
Why AirGreen for your next project in Laval
Our value lies in precise diagnosis , careful implementation and follow-up . We combine aesthetics , performance and regulatory compliance for installations that last over time. Whether for a plex, a condominium or a single-family home, we adapt the wall-mounted heat pump to your reality: volumes to be treated, facade constraints, noise, maintenance access and budget.
Planning an installation in Laval, Montreal, Longueuil, on the North Shore, or the South Shore? Let's talk about your living space, your savings goals, and your building's requirements: we'll design a custom HVAC solution, ready for Quebec's humid summers and winters.