Installation of a Sharp Eco Inverter wall-mounted heat pump in Verdun
AirGreen installs a Sharp Eco Inverter in Verdun: raised condenser, neat exterior chute, back-to-back and complete commissioning. Sustainable HVAC installation for Greater Montreal (Montreal, Laval, Longueuil, North Shore, South Shore).

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A raised outdoor installation, ready for Montreal's winter
At AirGreen , we design each HVAC installation to ensure it remains efficient year-round, without increasing maintenance. In this Verdun residence, we installed a Sharp wall-mounted heat pump ( Eco Inverter range) with an outdoor condenser on a raised support . The goal: to guarantee adequate clearance in all seasons, facilitate snow removal and maintain efficiency when temperatures plummet.
Client context and needs
The owner wanted to stabilize the comfort of the ground floor, reduce the use of electric baseboard heaters, and reduce humidity fluctuations during heat waves. A single-zone system was the obvious choice: a well-sized wall-mounted heat pump efficiently covers the main living area while remaining discreet and easy to maintain.
Installed equipment and sizing logic
-
Brand : Sharp
-
Range : Eco Inverter (continuous modulation technology)
-
Type : wall-mounted heat pump (mini-split)
-
Capacity : realistic sizing for a main room in a townhouse (in practice, a range around 9,000–12,000 BTU , validated after taking measurements).
-
Sharp special feature : Plasmacluster treatment on the indoor unit side, appreciated for air quality when windows are closed.
-
Efficiency : eligible pairing for air conditioning and heating performance criteria in cold weather, with configurations often Energy Star depending on the indoor unit/condenser duo selected.
This sizing avoids short cycles, limits ventilation noise and takes advantage of the inverter to smooth consumption.
Outdoor installation: stability, clearances and longevity
The condenser is placed on a raised metal support fixed to the rear deck. This technical decision responds to several concrete challenges:
-
Useful height : the raised height protects the unit from snow on the ground, protects the chassis from splashes and facilitates the flow of condensate in air conditioning mode.
-
Clearances : We maintain service clearances around the front and sides to ensure ventilation, panel access, and defrosting.
-
Vibrations : the feet are placed on anti-vibration pads; the anchoring is controlled so as not to transmit waves to the structure.
-
Orientation : The grille faces an open area to avoid recirculation of hot air in summer and to limit plumes in winter.
The refrigeration path exits the neighboring wall into a clean, sealed exterior duct . We deliberately reduce the length of the connections to contain pressure losses and preserve the actual capacity of the unit.
Refrigeration and drainage path: simplicity and reliability
-
Back-to-back : the interior head is behind the wall; the connections pass through the wall at a short distance, which limits welding and improves efficiency.
-
Insulation : The line insulation is high-density, sheathed and UV-sealed; each connection is protected by a finishing tape designed for our winters.
-
Condensate : gravity drain with continuous slope to the outside; outlet protected against frost and backflow. This approach eliminates the need for a pump, reduces noise and maintenance.
Electricity and compliance
Our dedicated master electrician carries out:
-
a dedicated circuit from the panel, with suitable circuit breaker and rating;
-
a disconnect switch near the condenser for isolation during HVAC maintenance ;
-
UV-resistant outdoor wiring and compliant grounding.
Each intervention is documented (photos, markers, AHRI numbers, diagram), useful for grant applications and subsequent monitoring.
Commissioning: AirGreen method
-
Extended vacuum and nitrogen leak test .
-
Checking the pressures/temperatures , intensities and stability of the Inverter compressor.
-
Control of defrosting and low temperature behavior.
-
Fine adjustments: orientation of the shutters, silent speeds, night mode , instructions adapted to the habits of the house.
-
Provision of a user guide (cleaning filters, maintenance schedule, warning signs to watch for).
Results obtained
-
More uniform temperature in the living area;
-
Humidity better controlled during heatwaves;
-
Reduced use of plinths in the off-season;
-
Sound level contained thanks to modulation and good sizing ;
-
Clean and clear exterior, compatible with quick snow removal from the patio.
Execution details visible on site
-
Support on galvanized legs : rigidity and durability, ideal for backyards;
-
Beige trunking matching the cladding, discreet screwing, waterproof caps;
-
Short route connections, few bends, limited welds;
-
Stainless steel fixings at exposed points;
-
Surface under the support leveled to distribute the load and avoid stagnant water.
HVAC Maintenance: Three Habits That Make a Difference
-
Filters : vacuum/rinse every 4 to 6 weeks during use;
-
Exterior clearance : keep the condenser face free of leaves and snow;
-
Annual inspection : cleaning exchangers, electrical check, tightening terminals, drain validation.
These actions maintain seasonal performance and extend the life of the heat pump .
Grants and administrative support
Sharp Eco Inverter kits that meet the efficiency and cold weather heating thresholds are generally eligible for grant programs in Quebec. We:
-
validate the eligibility of the specific pairing;
-
provide detailed invoice, AHRI number , photos of the installation and certificate;
-
guide the client in transmitting documents.
Result: a complete file, submitted quickly, and an optimized financial return.
Common Pitfalls Avoided on This Project
-
Condenser too low : sensitive to frost and snow drifts;
-
Air recirculation : orientation and clearances studied;
-
Uninsulated drain : risk of freezing and internal dripping;
-
Connections too long : loss of yield;
-
Undersized fasteners : noise and micro-vibrations.
On this site, each point is treated at the source for stable performance.
Practical recommendations for similar configurations
-
Provide at least 12–18 in. of raised support in yards prone to accumulation;
-
Maintain a 60–90 cm service path in front of the gate for maintenance;
-
Position the condenser away from roof discharges;
-
Program a stable setpoint (e.g. 23°C in summer, 20–21°C in winter) to take advantage of modulation;
-
Schedule annual HVAC maintenance just before the busiest season.
Why entrust your installation to AirGreen?
We operate weekly in Montreal, Laval, Longueuil, and on the North and South Shores, using proven procedures: precise measurement, transparent recommendations, meticulous finishing, comprehensive technical documentation, and responsive after-sales service . Our approach focuses on durability, ease of maintenance, and measurable daily comfort. In Verdun , as throughout Greater Montreal, we deliver a clean construction site, a well-calibrated installation, and a seamless customer experience.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).