Installation of a Sharp Inverter wall-mounted heat pump in Chomedey
AirGreen installs a Sharp Inverter wall-mounted heat pump in Chomedey: discreet capping near the patio door, gravity drain, short connections and rigorous commissioning. Ideal for condos in Montreal , Laval , Longueuil , North Shore , South Shore .
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The article, chapter by chapter
Four-season comfort in an apartment with a balcony: neat integration above the patio door
At AirGreen , we have just completed the HVAC installation of a Sharp Inverter wall-mounted heat pump in an apartment in the Chomedey sector of Laval . The project meets a common request in residential settings: efficiently air conditioning the main living area without sacrificing aesthetics, while adding reliable heating support in the spring and fall. The indoor unit is positioned above the patio door , a strategic location to cover the living room and adjoining dining room, with a blower that remains comfortable at occupant height.
Client objectives and constraints
-
Stable temperature in summer and winter, with fine modulation in mid-season.
-
Discreet integration near the curtains and the bay window, without encroaching on the furniture.
-
Easy access for periodic maintenance and filter cleaning.
-
Minimal route of refrigeration connections to the outside (balcony), in order to limit heat losses and optimize seasonal efficiency.
Technology choice and capacity
We are choosing a wall-mounted heat pump with a DC inverter compressor , which is ideal for partial load modulation. In an apartment of this size, the 9,000 to 12,000 BTU/h range covers the majority of needs, subject to insulation, facade orientation, and solar gains. The inverter continuously adjusts the speed of the compressor and fan, which:
-
reduces on/off cycles ,
-
lowers consumption when demand is moderate,
-
stabilizes temperature and improves acoustic comfort.
Interior layout: precision and finishes
-
Installation height : just below the ceiling, respecting the recommended clearances for air intake, in order to avoid any short recirculation.
-
Air diffusion : orientation of the shutters to sweep the room without direct air current towards the sofa or the dining area.
-
Finish : vertical passage in a discreet white capping adjacent to the patio door frame; neat aesthetics and easy access to the connections for future maintenance.
-
Condensate drain : gravity drain with a continuous slope towards the outside. We check the slope with a level and install an anti-siphon if necessary to ensure a smooth and quiet flow.
Outdoor route and connection management
The balcony configuration allows a very short path between the indoor head and the outdoor unit:
-
Refrigeration piping made of deoxidized copper, brazed under nitrogen, continuously insulated with closed-cell foam, then UV-sheathed to resist bad weather.
-
Communication/power cable secured to the harness, sections in accordance with the manufacturer's specifications.
-
Curve radii respected to protect the compressor and avoid any loss of load.
-
Waterproof wall penetration (compatible sealant) and interior/exterior collars for a clean finish.
Power supply and safety
-
Dedicated circuit from the electrical panel, circuit breaker calibrated according to the nominal current.
-
External disconnect switch near the condenser for disconnection during HVAC maintenance .
-
Grounding and loop management to reduce any risk of electromagnetic noise.
-
Surge protection option recommended in co-ownership to preserve the Inverter electronics.
Commissioning: method and quality controls
We apply our AirGreen protocol, a guarantee of reliability:
-
Nitrogen test of the circuit (high pressure) to check the integrity of the brazing.
-
Deep vacuum draw down to ≤ 500 microns , stabilization and rise test to confirm absence of moisture.
-
Load release/adjustment according to the prescribed weight and actual length of the links.
-
Functional control in air conditioning and heating: intensity, overheating/subcooling, supply/return temperature, and noise check in night mode.
-
User settings : Auto/Quiet modes, timer, shutter memory position, provision of a best practices guide.
Results: immediate comfort and controlled silence
-
Even cooling of the living area, even in late sunny afternoons;
-
Efficient heating supplement in mid-season, limiting the use of baseboards;
-
Acoustics : low interior noise level, external vibrations contained thanks to the stable support and the variable speed compressor;
-
Aesthetics : capping aligned with the bay window upright, visually integrated device.
Measurable results and operating advice
Preventive maintenance: simple and cost-effective
Regular HVAC maintenance extends lifespan and preserves performance:
-
Washable filters : wash/vacuum every 4 to 8 weeks in summer;
-
Batteries (evaporator/condenser): dusting and gentle cleaning to maintain heat exchange;
-
Annual AirGreen checks : sealing, pressures/parameters, electrical tightening, condensate test, condition of UV ducts and capping.
-
Winter : Keep the defrost drain area free of ice and snow (if the condenser is on an open balcony).
Optimal daily use
-
Let the inverter modulate: avoid repeated complete shutdowns .
-
Program a stable setpoint (24–25°C for comfort cooling, 20–21°C for additional heating).
-
Use night mode to lower the noise level and soften thermal transitions.
-
Close the curtains during the sunniest hours to reduce solar gain and consumption.
Sizing: Why “right” is better than “big”
Oversizing a heat pump is detrimental to comfort (frequent shutdowns, temperature variations, noise). Accurate sizing takes into account:
-
of the actual volume to be processed,
-
solar gains (patio door),
-
of the sealing of the envelope,
-
occupation profiles .
Our internal calculators and on-site readings guide capacity selection to balance comfort , consumption and durability .
Grants and Eligibility
Several Sharp Inverter configurations achieve high efficiencies and maintain useful capacity at low temperatures . Depending on the ENERGY STAR certification and the AHRI reference of the indoor/outdoor unit pair, the installation may be eligible for current assistance programs . We support our customers in **Montreal, Laval, Longueuil, the North Shore and the South Shore for:
-
validate the criteria (cold performance, SEER/HSPF),
-
gather evidence (technical sheet, AHRI ),
-
submit applications on time.
Mistakes to avoid (and that we often correct)
-
Lack of slope on the drain: source of odors and leaks — we systematically check the level.
-
Connections that are too long or sharply bent: pressure losses and reduced efficiency — we aim for the shortest route.
-
Unsealed drillings : risk of air/water infiltration — our penetrations are sealed and finished with collars .
-
Electrical undersizing : circuit breaker, rating and disconnect must follow the nameplate — we calibrate and test before delivery.
Why entrust your project to AirGreen?
-
Certified team accustomed to co-ownership constraints (regulations, access, nuisances).
-
Clean interior finish : aligned caps, painted/coordinated screws, clean repairs around the patio door.
-
Responsive after-sales service : maintenance, diagnostics, original parts.
-
Coverage of Greater Montreal : Montreal , Laval , Longueuil , North Shore , South Shore .
Balance sheet
This Sharp wall-mounted heat pump installation in Chomedey offers immediate comfort , low noise , and controlled consumption thanks to inverter modulation and short wiring routes . The interior head, perfectly integrated above the patio door, frees up space and distributes air evenly. With annual HVAC maintenance and appropriate use, the system will maintain its performance season after season.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).