Installation of a Sharp (R-32 range) wall-mounted heat pump in Chomedey (Laval)
AirGreen installs a Sharp wall-mounted heat pump (R-32) in Chomedey : minimal path, gravity drain and silent diffusion for a living room open to a patio door . Complete HVAC service in Montreal , Laval , Longueuil , South Shore and North Shore .

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A living room that is better heated in winter and cooler in summer: discreet installation near a patio door, short lines and high efficiency
In this Chomedey (Laval) apartment, our AirGreen team installed a new generationSharp wall-mounted heat pump (R-32 refrigerant) to stabilize the comfort of a living space open to a patio door . The client's goal: efficient heating in cold weather , quiet air conditioning during heat waves, and clean integration without major work. We designed a very short path between the wall-mounted head and the outside, with gravity condensate drainage , to optimize performance and reduce maintenance.
The context: long room, patio door and family circulation
-
Elongated main room , circulation along a clear wall which ends with a patio door opening onto a balcony.
-
Diffusion requirements : Avoid direct air currents on the seating area, while sweeping the entire volume.
-
Noise : priority to silence so as not to disturb daily activities (reading, television, teleworking).
-
Maintenance : Easy access to washable filter and covers for annual HVAC maintenance.
Why a Sharp wall-mounted heat pump (R-32) for this project?
Seasonal efficiency and cold behavior
Sharp 's new generation R-32 wall-mounted units feature high seasonal efficiencies (SEER/HSPF higher than the R-410A generation) and reliable heating at low temperatures , essential for the Montreal and Laval regions . The variable-speed compressor finely modulates power to maintain the setpoint smoothly, thus limiting consumption.
Acoustic comfort and air quality
The internal design promotes very low noise levels and wide diffusion thanks to the panoramic shutter. The washable filters can be removed without tools, simplifying HVAC maintenance and maintaining good air quality.
Adaptation to the room
In a long room open to the outside, the high wall head, offset from the passage, allows for efficient transverse sweeping . The fan mode and shutter angle adjustment have been set to avoid dead zones near the patio door and to protect the sensors from solar gain.
Our step-by-step HVAC installation methodology
1) Study and preparation of the wall
We validate the installation template on a supporting support (upright behind the plasterboard or suitable dowels), then we ensure:
-
sufficient clearance above the patio door,
-
a clear blowing on the main axis of the part,
-
the slope of the drain to favor gravity evacuation (the most reliable and silent solution).
2) Drilling and technical crossing
-
Through hole (≈ 65–70 mm) in the corner near the patio door to exit directly to the outside and reduce the length of the connections.
-
Installation of a bulkhead , a vapor barrier and protection of the insulation to prevent any abrasion in the core of the wall.
-
Continuous slope towards the outside for the gravity drain : no condensate pump, therefore zero additional noise and simplified maintenance .
3) Refrigeration and electrical connections
-
Short lines (typically ≤ 3–4 m), which reduces pressure losses and improves COP in heating.
-
Flared fittings tightened to controlled torque , deep vacuum (≤ 500 microns), then nitrogen leak test before opening the valves.
-
Shielded communication cable and power supply in accordance with the manufacturer's specifications, with clear marking for subsequent service.
4) Outdoor unit and winter protection
Outside, we position the condenser on a support clear of the ground (brackets or anti-vibration base) in order to:
-
stay above the snow level in winter,
-
ensure suction and blowing clearances ,
-
allow automatic defrosting without air recirculation.
We direct water drainage away from traffic areas to avoid ice .
5) Commissioning and optimization
-
Controlled start , pressure check, superheat and subcooling , current control.
-
Calibration of fan speeds, AUTO mode and inter-season setpoints to maintain modulating operation .
-
Customer training : best practices (stable setting, filter maintenance), use of dehumidification mode in summer, programming advice.
Visible details and key technical choices
Location near a patio door
-
The wall head is installed high up , aligned with the ceiling drop, to avoid air shock on the occupant and to benefit from a natural air mixture with the glazed area.
-
The blowing angle is adjusted to sweep the length of the room, without blowing directly on people or curtains.
Minimum route and finishes
-
Immediate output to the outside as close as possible to the unit: reduced connection length , limited losses, rapid response in heating and air conditioning.
-
Discreet capping and watertight fittings to protect connections and facilitate future maintenance .
Gravity drain
-
Condensate drainage is by gravity thanks to the slope of the feedthrough. Advantages: no pump vibration, total silence and increased reliability .
Results measured after commissioning
-
Fast temperature rise in cold weather thanks to short lines and compressor modulation.
-
Uniformity of comfort throughout the room, even with regular opening of the patio door .
-
Very low noise , compatible with teleworking and relaxation.
-
Controlled consumption : the R-32 heat pump provides more useful heat per kWh than electric baseboards, reducing seasonal bills.
HVAC Maintenance: Our AirGreen Recommendations
To be done by the occupant
-
Clean filters every 4 to 8 weeks depending on use and the presence of animals.
-
Keep 1.5 m clear in front of the wall head for optimal blowing .
-
In winter, visually check that the outdoor unit remains free of snow and ice .
Annual professional interview
-
Inspection of heat exchange (interior/exterior).
-
Checking the tightening , drain , and sealing .
-
Control of refrigeration parameters to maintain efficiency and longevity .
Grants and local compliance
When configuration and performance allow, we direct our clients to the grant programs available for high-efficiency heat pumps . Our installations comply with RBQ requirements and good installation practices in Greater Montreal (clearances, protections, anchors), whether in Montreal , Laval , Longueuil , on the South Shore or the North Shore .
What we bring to a site like this
Rigorous sizing
Choosing the right capacity (BTU) depends on the envelope, orientation, infiltration, internal contributions and use. We avoid oversizing (short cycles, discomfort) as well as undersizing (noise, wear).
Optimized route = efficiency and reliability
Our priority is to obtain the shortest possible connections , a gravity drain , and fixings that simplify maintenance . The result: higher performance , fewer risks and a lower total cost of ownership .
AirGreen Monitoring
After commissioning, we offer seasonal monitoring , preventive maintenance and support . In case of changing needs (e.g. adding a second zone), we offer scalable solutions compatible with the existing configuration.
Site sheet - highlights
-
Location : Chomedey (Laval) .
-
Equipment : Sharp wall-mounted heat pump , R-32 refrigerant (recent range).
-
Interior installation : above the passage, near the patio door , transverse blowing.
-
Route : direct crossing , short lines (≈ ≤ 3–4 m), discreet capping .
-
Condensates : gravity drain (no pump).
-
Benefits : silence , thermal stability , energy savings , clean integration .
Are you planning an HVAC installation in Montreal , Laval , Longueuil , South Shore or North Shore ? We size, install and maintain R-32 / R-454B wall-mounted heat pumps adapted to local buildings, with careful and durable installation.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).