Job sheet · Project

Installation of a Sharp ZU1 wall-mounted heat pump in Côte-des-Neiges–Notre-Dame-de-Grâce

At AirGreen, we installed a Sharp ZU1 wall-mounted heat pump in Côte-des-Neiges–Notre-Dame-de-Grâce. A project combining performance, discreet design, and optimal comfort for a perfect indoor climate all year round.

By AirGreen Climatisation & Chauffage Admin3 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
3 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a Sharp ZU1 wall-mounted heat pump in Côte-des-Neiges–Notre-Dame-de-Grâce
Installation of a Sharp ZU1 wall-mounted heat pump in Côte-des-Neiges–Notre-Dame-de-Grâce
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

An elegant and efficient integration in the heart of a Montreal kitchen

At AirGreen , we recently installed a Sharp ZU1 wall-mounted heat pump in a charming apartment in the Côte-des-Neiges–Notre-Dame-de-Grâce area of ​​Montreal. This project perfectly illustrates how to combine energy performance , aesthetic discretion and thermal comfort in an urban environment with limited space.

An installation adapted to Montreal condo life

In this typical Montreal apartment, the kitchen layout required a precise and meticulous approach. The indoor unit was installed above the wall panel, a strategic position that allows for even air distribution while freeing up work and storage space. This placement ensures optimal circulation of hot and cold air throughout the main room, while avoiding any interference with cooking surfaces or upper cabinets.

Choose Sharp ZU1: performance and silence

The Sharp ZU1 is one of the brand's latest and most efficient models. Thanks to its R-32 refrigerant , it offers remarkable energy efficiency while reducing its environmental impact. Capable of operating efficiently down to -25°C , this wall-mounted heat pump is perfectly suited to the harsh winters of Greater Montreal.

Among its main assets:

  • Quiet operation , ideal for open spaces or kitchens.

  • Intelligent dehumidification mode , particularly appreciated during Montreal summers.

  • Precise temperature sensors , allowing uniform regulation of comfort.

  • Simplified maintenance thanks to quick access to washable filters.

Careful integration work by AirGreen

The AirGreen team ensured a discreet and harmonious installation , respecting both the aesthetic and technical constraints of the space.
The main technical points of this achievement:

  • Direct and sealed wall drilling towards the outside.

  • Short refrigerant line , minimizing energy losses.

  • Gravity drainage facilitated by a slight internal slope, avoiding the addition of a condensate pump.

  • Discreet power supply , connected to a dedicated circuit breaker according to Canadian standards.

This approach ensures both better system durability , maximum energy efficiency and reduced noise levels in the room.

Why choose a wall-mounted heat pump in a condo?

In Montreal apartments and plexes, wall-mounted heat pumps are often the most logical solution:

  • Quick installation, without conduits.

  • Excellent performance/price ratio.

  • Eligibility for Quebec energy subsidies (depending on model and performance).

  • Possibility of heating and air conditioning at low cost all year round.

The Sharp ZU1 , in particular, offers an ideal balance between compact design and cutting-edge technology , making it a popular choice for homeowners looking to upgrade their comfort without compromising interior aesthetics.

Four-season comfort from AirGreen

Today, occupants enjoy tailored comfort, summer and winter. The unit ensures a stable and pleasant temperature, even during heat waves or extreme cold. Our client noted the immediate difference in air quality and the significant reduction in electricity consumption within the first few weeks of use.

At AirGreen, we strive to ensure that every installation is a testament to reliability, durability, and professionalism . Whether it's a downtown condo, a suburban home, or a multi-unit building, our team ensures that every HVAC project reflects our commitment to excellence and precision.

AirGreen: Your HVAC Expert in Montreal and Beyond

We operate throughout Greater Montreal— Montreal, Laval, Longueuil, the North Shore, and the South Shore —to install, maintain, and optimize your heating and air conditioning systems. Our experts, certified in Sharp, Fujitsu, Midea, Gree, and more, guarantee service that meets the highest standards.

To learn more about our Sharp ZU1 wall-mounted heat pump installations , or to get a free evaluation of your project, contact AirGreen today: we will be happy to assist you in your journey towards sustainable energy-efficient comfort .

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment