Installation of an ELIOS R454B central heat pump in Henryville, Montérégie
In Henryville, AirGreen installs an ELIOS R454B central heat pump on an elevated stand, with protected lines and optimized service access to ensure year-round comfort, reliability, and performance.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.
The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.
A shut-off switch near the outdoor unit isolates it safely for service.
Sitting on the indoor module, it moves heat between the house air and the refrigerant.
Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.
Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.
It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.
It runs the heat pump and the backup heat. It must be compatible with the installed system.
A Central Installation Designed for Henryville’s Climate and the Building’s Real-World Constraints
At Henryville, this installation of an ELIOS central heat pump operating with R454B refrigerant perfectly illustrates the importance of adapting each central heating and cooling project to the building’s configuration. A heat pump cannot simply be placed outdoors and connected quickly: its location, height, clearances, line protection, and maintenance access directly affect its reliability.
At this brick property, our AirGreen team had to position the outdoor unit in a relatively narrow space along the foundation. The proximity of the wall, the presence of a side fence, the winter conditions in Montérégie, and the route of the refrigerant lines required precise planning.
The result is a compact, clean installation, with the outdoor unit installed on a raised support, the connections grouped along the side of the building, and the electrical components accessible. This arrangement preserves the space around the home while maintaining the conditions required for the central heat pump to operate.
Why an ELIOS R454B Central Heat Pump?
A central heat pump uses the existing or newly installed ductwork to distribute heated or cooled air throughout the various rooms. Unlike a wall-mounted heat pump, it does not rely on a visible indoor unit in a single area. Instead, it is integrated into a central system consisting mainly of:
- an outdoor unit;
- a compatible indoor unit or coil;
- a central fan;
- a thermostat;
- a supply-and-return air duct network;
- refrigerant lines connecting the components.
In this project in Henryville, the ELIOS R454B outdoor unit is the visible part of the system. It captures or releases heat depending on the season, while distribution throughout the home is handled by the central indoor system.
Choosing the Refrigerant R454B responds to the evolution of HVAC technologies toward fluids with a lower global warming potential than several refrigerants used in previous generations. However, this type of system must be installed using tools, procedures, and components compatible with the refrigerant specified by the manufacturer.
At AirGreen, we never mix practices applicable to older equipment with those required for a new heat pump. The type of refrigerant notably affects handling procedures, leak-tightness checks, evacuation, circuit charging, and certain safety measures.
Capacity Determined According to the Building’s Needs
The capacity of a central heat pump should never be selected solely based on the home’s approximate area. Two buildings of similar size can have very different requirements depending on:
- their insulation level;
- the number and type of windows;
- the tightness of the building envelope;
- exposure to sun and wind;
- ceiling height;
- the duct configuration;
- the region’s design temperature;
- the presence of auxiliary heating;
- the actual available airflow.
For an installation in Henryville, we must also take the Montérégie’s winter temperatures into account. An oversized unit can cause short cycling, less stable humidity control, and uneven comfort. An undersized unit, on the other hand, may place excessive demand on the supplemental heating system during cold periods.
The exact capacity must therefore be confirmed based on the technical documentation, the indoor-outdoor combination, and the building’s characteristics. This method is more rigorous than stating a BTU capacity without validating the complete configuration.
An Outdoor Positioning Solution for a Restricted Side Space
The photograph of this installation shows that the unit was placed near the brick wall, in a relatively narrow side passage. This type of location requires several checks before drilling or securing the mounting bracket.
In particular, we must ensure that the unit has sufficient clearance to draw in and discharge air. The large front fan must not blow directly against an obstacle that is too close. The rear and sides must also comply with the clearances specified in the manufacturer’s documentation.
Insufficient clearance can result in:
- recirculation of discharged air;
- reduced capacity;
- abnormal operating pressure;
- less effective defrosting;
- increased noise;
- difficulty accessing the system during HVAC maintenance;
- premature wear of certain components.
In this case, the orientation of the unit’s front panel allows the fan to discharge air toward the open space rather than toward the wall. The connections are grouped on the right side, near the foundation, which reduces the exposed length of the lines.
A Raised Installation for Better Winter Performance
One of the most important details of this installation is the height of the outdoor unit. The ELIOS heat pump was not installed directly on the ground. It rests on a raised, securely fastened metal support.
This height is particularly relevant in Henryville, where snow accumulation can become significant around buildings. A unit installed too low may be partially obstructed by snow, ice, or snow pushed during snow removal.
A central heat pump in heating mode also produces water during its defrost cycles. This water must be able to drain beneath the unit without immediately creating a mass of ice against the base of the cabinet.
The elevated installation helps to:
- keep the air intake clear;
- limit contact with snow;
- promote the drainage of defrost water;
- reduce exposure to leaves and debris;
- facilitate inspection beneath the unit;
- reduce the risk of corrosion caused by stagnant moisture.
However, the owner must avoid allowing snow to accumulate under the fan or around the support. The area must be cleared carefully, without striking the fins or using a tool that could damage the cabinet.
Stable fastening near a masonry wall
The weight and vibrations of an outdoor unit must be distributed properly. An unstable support can transmit noise to the structure, alter the cabinet’s inclination, or place stress on the refrigerant connections.
In this installation, the heat pump is supported by a metal structure offering several points of support. Vibration-damping components are placed between the unit’s feet and the support to limit vibration transmission.
This precaution is particularly useful when the unit is near a brick wall. Improper fastening can create a noticeable buzzing sound indoors, especially in a nearby bedroom or living space.
We therefore check:
- the strength of the foundation;
- the unit’s level;
- the rigidity of the support;
- the tightness of the fasteners;
- the absence of tension on the lines;
- clearance beneath the cabinet;
- access to the service panels.
Protected and organized refrigerant lines
The two lines connecting the outdoor unit to the indoor central system are visible on the right side of the unit. The larger-diameter suction line is covered with black insulation. This insulation is essential for limiting heat gain or loss and preventing condensation from forming on the piping.
The connections must not be sharply bent or subjected to tension. Curves that are too tight can reduce the tube’s internal diameter or weaken the copper. On this project, the routing is compact but gradual enough to reach the entry point in the building.
A professional installation normally includes several steps that are invisible once the system is running:
- preparing and cleanly cutting the lines;
- making the connections according to the manufacturer’s requirements;
- pressurizing the system to check for leaks;
- evacuating the refrigeration circuit;
- maintaining the vacuum to confirm that there are no leaks;
- opening the service valves;
- checking temperatures and pressures;
- verification of operation in heating and cooling modes.
Simply turning the system on does not, by itself, confirm the quality of the installation. Moisture or air left in the circuit can cause problems that may not appear until several months later.
Accessible power supply for servicing
Near the unit, the outdoor electrical box used to isolate power to the heat pump can be seen. This disconnect allows the technician to shut off power locally during an inspection, maintenance, or repair.
The circuit breaker rating, cable type, and electrical protection must correspond to the information listed on the unit’s nameplate. A circuit breaker should never be selected solely according to the rated capacity expressed in tons or BTUs.
The manufacturer’s nameplate provides important values such as:
- minimum circuit ampacity;
- maximum overcurrent protection;
- rated voltage;
- number of phases;
- electrical frequency;
- the exact model of the unit.
This information must be followed to ensure installation safety and preserve the manufacturer’s warranty.
This Henryville project demonstrates why installation details matter just as much as the equipment
A central system is not limited to replacing the outdoor unit
When a homeowner compares prices for a central heat pump installation in Henryville, it can be tempting to compare only the brand and advertised capacity. However, final performance depends on the entire system.
Before installing a new central unit, we must verify compatibility with:
- indoor coil;
- electric furnace or forced-air heating system;
- fan motor;
- thermostat;
- auxiliary heating controls;
- refrigerant line diameter;
- duct dimensions;
- airflow;
- condensate drainage.
A high-performance unit connected to an overly restrictive duct system will not deliver the expected results. Insufficient airflow can cause noise, poor distribution, frost on the coil, and reduced efficiency.
The importance of checking existing ductwork
In many homes in Montreal, Laval, Longueuil, the North Shore, the South Shore, and Montérégie, the ductwork was designed for an older furnace, sometimes without considering the requirements of a modern heat pump.
We pay particular attention to the following elements:
- return-air dimensions;
- number of supply grilles;
- overly restrictive filters;
- crushed or improperly connected ducts;
- closed registers;
- air leaks at the joints;
- uninsulated ducts in cold areas;
- balance between floors.
When necessary, targeted corrections can make a major difference without rebuilding the entire system. These may include enlarging a return, adding a grille, sealing connections, or correcting an improperly sized duct.
Drainage during air conditioning
In summer, the indoor coil removes some of the moisture from the air. This water must be discharged through a properly installed condensate drain.
An improperly sloped or partially blocked drain can cause:
- an overflow near the indoor unit;
- damage to the ceiling or floor;
- odors;
- the formation of biological deposits;
- system shutdown if a safety switch is installed.
During our HVAC installations, we check not only the drain connection but also its routing and discharge point. This discreet component can prevent costly damage.
Common mistakes to avoid around the outdoor unit
After installation, certain modifications made around the house can reduce the heat pump’s performance. We recommend avoiding the following mistakes.
Building an enclosure that is too closed
A roof can sometimes protect the unit from falling ice, but the sides must not block airflow. An enclosed decorative enclosure can cause significant recirculation and impair performance.
Stacking objects near the fan
Bins, tools, bags, and construction materials must be kept away from the unit. The front clearance must remain unobstructed.
Letting vegetation overgrow the coils
Leaves, grass, and branches can reduce airflow through the outdoor coil. Vegetation should be trimmed regularly.
Directing a gutter toward the heat pump
Water from the roof should not fall directly onto the unit. In winter, it can form a layer of ice on the cabinet or support.
Using a metal shovel too close to the cabinet
When removing snow, avoid impacts against the fins, piping, and panels. A plastic shovel used carefully is preferable.
Recommended maintenance for an ELIOS central heat pump
Regular maintenance helps maintain system performance and detect issues before a breakdown.
The owner can perform a few simple checks:
- replace or clean the filter according to the type used;
- keep the return grilles clear;
- clear the outdoor unit;
- monitor unusual noises;
- check for water around the indoor unit;
- note any unexplained increase in electricity consumption.
Professional maintenance goes further. Depending on the system configuration, our technician can inspect:
- the coils;
- the fan;
- electrical connections;
- supply and return air temperatures;
- drainage;
- controls;
- auxiliary heating;
- defrost cycles;
- the condition of the refrigerant lines.
A heat pump that is still operating may nevertheless show reduced performance. Early detection often prevents a minor issue from becoming a complete failure during a cold or hot spell.
Subsidies and eligibility: the complete combination must be verified
Certain central heat pumps may qualify for financial assistance programs when the exact combination of the outdoor and indoor units meets the current criteria.
Eligibility should never be determined solely by the brand logo or refrigerant type. It generally depends on:
- complete model numbers;
- the certified combination;
- low-temperature heating capacity;
- energy efficiency;
- the type of building;
- the program applicable at the time of installation;
- the required documents and invoices.
At AirGreen, we verify the relevant technical references before confirming a subsidy. This precaution protects the client from estimates based on a similar but not identical model.
A simple, accessible installation adapted to the building
This project in Henryville does not rely on a complex presentation. Its quality lies in the details: a properly oriented, elevated, stable ELIOS R454B unit, cleanly connected and accessible for servicing.
The proximity of the brick wall was managed without compromising airflow. The support helps protect the unit from snow accumulation. The lines follow a short, organized route, while the electrical disconnect remains accessible.
This is precisely the approach we apply to our central heat pump projects in Montreal, Laval, Longueuil, on the North Shore, South Shore, and in Montérégie. We assess the building as a whole rather than treating the unit as an independent component.
A properly completed central installation should provide consistent comfort, even air distribution, safe operation, and reasonable access for future maintenance. When these elements are planned from the outset, the heat pump can better fulfill its role during both Quebec’s humid summers and harsh winters.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
The equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
Access protected, old unit disconnected and removed when it is being replaced.
Electric furnace or air handler, with its coil, connected to the supply and return ducts.
On a level base, raised above the snow, with free space all around.
Insulated, they enter through a sealed opening and run to the indoor coil.
Dedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
Leak test, vacuum, start-up, airflow check and a test of both modes.
Filter, thermostat, backup heat in extreme cold: what to know before winter.
- The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
- The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
- Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
- The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
- The outdoor unitOn a level base, raised above the snow, with free space all around.
- The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
- Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
- Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
- The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Check the indoor module's filter.
- Clear winter debris from the outdoor unit.
- Test cooling before the heat arrives.
- Check the filter more often in peak season.
- Keep registers and returns clear.
- Watch condensate drainage near the coil.
- Change or clean the filter.
- Test heating and backup heat before the cold.
- Book periodic maintenance.
- Clear snow around the outdoor unit.
- Store nothing in front of the indoor module.
- Note any unusual noise or smell and call us.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. A central heat pump uses the house's ducts.
It connects to the existing ducts to heat and cool everywhere.
2. In extreme cold, electric backup heat can take over.
The indoor module (furnace or air handler) works with the heat pump and takes over in extreme cold.
3. The filter only gets changed when the unit breaks down.
A dirty filter cuts airflow. It gets checked regularly.
4. You can reuse the old unit's size without checking.
The house may have changed: insulation, windows, added rooms. Capacity is confirmed on site.
0 / 4 right answers
What people ask us about this kind of work
Can I keep my current ducts?
What happens in extreme cold?
Furnace, air handler, ducted: what is the difference?
Are there grants?
Do I need a permit?
How much can I save?
How is the LogisVert assistance calculated?
Will my current thermostat work?
Central or wall units: which one?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).