Installation of a MIDEA EVOX G3 central heat pump in Elgin, Montérégie

In Elgin, AirGreen installs a MIDEA EVOX G3 central heat pump on wall brackets: heating down to -30 °C, Inverter technology, R-454B, and HVAC integration adapted to the home.

By AirGreen Climatisation & Chauffage Admin18 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
18 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a MIDEA EVOX G3 central heat pump in Elgin, Montérégie
Installation of a MIDEA EVOX G3 central heat pump in Elgin, Montérégie
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Midea EVOX G3 · 1.5 tons14,70018,600−30 °C: 11,8002.1219.010.1$1,764
Midea EVOX G3 · 2 tons20,80020,600−30 °C: 12,1002.1418.610.0$2,496
Midea EVOX G3 · 2.5 tons24,00033,200−30 °C: 17,9001.9717.210.8$2,880
Midea EVOX G3 · 3 tons33,00037,400−30 °C: 27,6001.918.010.0$3,960
Midea EVOX G3 · 4 tons39,50048,000−30 °C: 27,2002.017.59.5$4,740
Midea EVOX G3 · 5 tons45,00054,000−30 °C: 37,3001.917.59.5$5,400

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

Under a window, against a brick wall, and near vegetation: an installation where every clearance had to be carefully considered

In Elgin, in Montérégie, this installation of a MIDEA EVOX G3 central heat pump presents a very different situation from a job site with a large, completely unobstructed exterior wall. Here, the outdoor unit had to be integrated into a brick facade beneath a large window, with vegetation immediately to the left and an outdoor area that needed to remain as functional as possible.

This is precisely the type of configuration in which the quality of an HVAC installation becomes apparent.

In the job-site photo, we see a new-generation MIDEA outdoor unit mounted on metal wall brackets, rather than placed directly on the ground. The equipment is therefore kept at a considerable height above the soil and low vegetation. The horizontal-discharge fan faces a completely open area, while the back of the unit remains against the masonry. To the left, the electrical disconnect is located near the equipment.

The setup is compact, but it does not look as though it was placed randomly. For us at AirGreen, that is precisely the challenge: making the most of the available space without compromising the heat pump’s operation, future accessibility, or performance during Quebec winters.

Why the EVOX G3’s format was particularly interesting here

The MIDEA EVOX G3 uses a horizontal-discharge outdoor unit. The large fan visible on the front of the heat pump therefore expels air forward, unlike traditional cubic central systems, whose fan is often positioned on top.

This design can be particularly useful when a property has limited available depth.

MIDEA’s technical documentation specifically describes a design with a horizontal-discharge fan and a high-efficiency vertical heat exchanger. The manufacturer indicates that this architecture is intended to achieve more uniform airflow through the heat exchanger and maintain good heat-exchange performance as the outdoor temperature drops.

On this Elgin project, the practical advantage is immediately apparent: the unit can run alongside the house while retaining the space required in front of its fan to discharge air.

However, a common mistake must be avoided: considering a horizontal-discharge heat pump to be a unit that can be enclosed in any narrow space. Airflow remains essential. A fence, dense shrub, snow accumulation, or another obstacle placed too close to the front can reduce air circulation and affect operation.

Nearby vegetation: a detail to monitor throughout the seasons

The photograph shows fairly abundant vegetation to the left of the installation.

When installing a central heat pump, conditions should not be assessed only on the day of installation. You must also imagine what will happen in July when the plants have grown, in October when leaves accumulate around the unit, and in January when snow occupies the ground-level space.

We therefore recommend regularly keeping vegetation away from the coil and air intake areas.

This does not require transforming the side of the house into a completely bare space. Simply make sure that branches, leaves, or plants do not come into contact with the heat pump or reduce the amount of available air.

On this project, positioning the unit on a wall bracket helps limit direct contact with vegetation at ground level.

An elevated heat pump rather than one placed directly on the ground

One of the most interesting details of this installation is the height of the outdoor unit.

The EVOX G3 is supported by two metal brackets firmly anchored to the masonry wall. The unit thus remains completely clear of the ground.

In southern Quebec, this way of installing a heat pump intended for heating represents a significant advantage.

During the winter, a heat pump extracts heat from the outdoor air. Frost periodically forms on the coil, and the machine must perform defrost cycles. The resulting water must be able to drain away.

If an outdoor unit is installed too low, the space beneath the machine may gradually become occupied by:

  • snow;
  • ice resulting from defrost cycles;
  • ice created by freezing and thawing periods;
  • leaves and debris;
  • vegetation;
  • or a mixture of several of these elements.

Proper elevation significantly reduces this risk and also makes visual inspection of the unit easier.

Installing on brick requires suitable fastening

The photo clearly shows that the supports are installed on an exterior brick wall.

A central outdoor unit represents a significant weight. The brackets must therefore be correctly sized and secured. They must also remain stable when the machine operates at different compressor and fan speeds.

Poor installation could create noticeable vibrations in the building or, over the long term, place unnecessary stress on the structure.

For us, installing the supports is never a secondary step. We specifically check the assembly’s geometry, the outdoor unit’s base, its level, and the anchoring points before considering this part of the job complete.

A central heat pump that continues to operate in very cold weather

Elgin’s climate imposes a very different requirement from that of a region where the heat pump is used primarily for cooling.

MIDEA presents the EVOX G3 Extreme Heat as a system capable of continuing to operate down to -30 °C. The documentation also indicates, for the configurations concerned, up to 100% heating capacity at -25 °C, with a COP of up to 1.9 under the conditions presented by the manufacturer.

The page devoted to cold-weather performance also explains the principle used by the compressor: when the system operates in extremely cold conditions, the circuit increases the amount of compressed refrigerant to support heating capacity.

For a homeowner, however, there is an important nuance to understand: “operates down to -30 °C” does not mean that all capacities and combinations deliver exactly the same performance at -30 °C.

We must always look at the specific system that will be installed.

An interesting test result at -25 °C, but one that must be interpreted correctly

In its documentation, MIDEA also presents a test result obtained on a 3-ton system.

The manufacturer reports, in particular, a COP of up to 2.4 at -15 °C and heating output of up to 118% of nominal capacity at approximately -25 °C, with a COP of 1.92 for the tested system. The brochure expressly specifies that this result is based on a 3-ton MIDEA system.

This is interesting data for understanding the technological capabilities of the EVOX G3 family, but we avoid turning this figure into a universal promise for every home.

Actual performance depends in particular on the installed tonnage, outdoor temperature, building heat load, indoor airflow, and certified matchup.

That is exactly why we prefer to discuss actual sizing rather than limit ourselves to the most impressive figures in a brochure.

What tonnage was installed in Elgin?

The photo clearly identifies the MIDEA family, the EVOX G3 format, and the outdoor configuration, but it does not allow us to read the complete model number on the rating plate with certainty.

We will therefore not invent the precise capacity of this installation.

The EVOX G3 range presented in the documentation includes several central configurations. The performance data sheet on page 11 includes systems rated at 18,000, 24,000, 30,000, 36,000, 48,000, and 54,000 BTU/h in cooling, with different heating capacities and efficiencies depending on the matchup.

This variety allows us to adapt the equipment to the building rather than forcing different types of homes to use the same tonnage.

Performance that genuinely varies from one capacity to another

MIDEA's specification analysis is instructive.

In the EVOX G3 table, a configuration rated at 30,000 BTU/h in cooling and 33,000 BTU/h in heating is listed at 17.2 SEER2, with a seasonal heating value of 10.8 in the documentation. A configuration rated at 36,000 BTU/h is listed at 17.7 SEER2, while the 48,000 BTU/h configuration is advertised at 17.5 SEER2.

According to MIDEA, the range reaches up to 19 SEER2, 12.5 EER2, 10.8 HSPF2, and a COP of up to 2.14 at 5 °F, or approximately -15 °C, depending on the system.

These differences demonstrate why the name "EVOX G3" is not enough to compare two quotes.

Two contractors can offer a MIDEA EVOX G3 heat pump while referring to systems with different capacities and different matchups.

The invisible part of this system: indoor air handling

The photograph mainly shows the outdoor condenser, but a central heat pump cannot be evaluated solely by its outdoor unit.

Inside is the air handler connected to the home's ductwork.

It is responsible for properly circulating hot or cold air to the different rooms.

The EVOX G3 indoor unit design uses what MIDEA calls an M-Coil with a symmetrical fan. According to the manufacturer, this architecture reduces airflow differences across the heat exchanger compared with a traditional configuration.

For an existing home, this is important because ductwork quality varies greatly from one property to another.

Computational Constant Airflow 2.0: particularly relevant during a renovation

The EVOX G3 also features Computational Constant Airflow 2.0 technology.

Its purpose is to adapt fan operation to different duct and filtration conditions. MIDEA indicates an adaptation capacity of up to 1.2 in. of water column static pressure in the examples presented, as well as an airflow volume adjustment of up to 60 levels.

This can be particularly useful when replacing an old furnace or an old central heat pump.

An existing network was not always designed specifically for the new equipment. It may include changes in cross-section, more restrictive filters, long runs, or significant differences between the various branches.

Constant airflow technology can help the system adapt, but it does not override the laws of aerodynamics. A significantly undersized duct remains undersized.

At AirGreen, we therefore want to know how the air actually circulates before concluding that a particular central heat pump is the right solution.

This Elgin project shows why an EVOX G3 must be installed as a complete system, rather than as a simple outdoor box.

An indoor unit designed for multiple orientations

One of the less visible but highly practical aspects of the EVOX G3 is its modular air handler.

MIDEA introduces a Block N Lock design allowing up to six installation orientations: vertical upflow, downflow, right horizontal, left horizontal, and various “low-boy” configurations for situations where available height is limited.

In an existing home in Elgin, Montreal, Laval, Longueuil, the South Shore or the North Shore, this flexibility can completely change how we approach a mechanical room.

We regularly encounter basements where the equipment must fit between a beam, a water heater, an electrical panel, and a main duct that is already in place. Being able to adapt the position of the indoor unit without unnecessarily rebuilding the entire mechanical room can considerably simplify the project.

A solution designed to replace certain older furnaces

The brochure also indicates indoor unit widths ranging from 14.5 to 21.5 inches depending on capacity, dimensions chosen to match those of several existing residential furnaces.

MIDEA also provides a 115 V or 208/230 V multivoltage power supply for the indoor unit, depending on the configuration, with automatic voltage identification.

This does not mean that a replacement is always “plug-and-play.”

We still need to check the electrical system, ductwork, sheet-metal transitions, condensate drain, return dimensions, and clearances.

But when a manufacturer designs its unit around the dimensions actually found in existing homes, it gives us more options on the job site.

Auxiliary heating up to 25 kW

Even with a heat pump capable of operating at very low temperatures, auxiliary heating remains an important component of a Québec central system.

EVOX G3 documentation provides for three-stage auxiliary heating kits capable of up to 25 kW, with settings and activation adapted to temperature variations.

The goal, however, is not to use the electric elements as soon as it gets cold.

A proper control strategy should allow the heat pump to meet the heating demand as efficiently as possible, then use auxiliary heating when conditions or the building load require it.

An improper configuration can unnecessarily increase the electricity bill.

R-454B: the next generation of refrigerant for the EVOX line

The EVOX G3 system presented by MIDEA uses R-454B refrigerant.

MIDEA indicates a global warming potential, or GWP, of 466, and uses this A2L refrigerant for its core EVOX line as well as for other product families.

For homeowners, this change seems relatively inconspicuous because the refrigerant circulates in a closed loop.

For the installer, however, it entails procedures, equipment, and handling practices appropriate for this new generation of refrigerants.

The contractor's choice therefore becomes particularly important during installation, maintenance, and any potential troubleshooting.

Communicating control or 24 V thermostat

The EVOX G3 also offers several control options.

MIDEA documentation indicates compatibility with 485 communication as well as conventional 24 V thermostats. The system is designed to identify its control mode according to the configuration used.

MIDEA also presents its communicating thermostat and SmartHome app, with scheduling, comfort management, consumption monitoring, and remote diagnostic tools.

For some homeowners, this connectivity is an important advantage. For others, the priority will simply be having a reliable, easy-to-use thermostat.

We can adapt the approach based on the system and the home's actual needs.

What about LogisVert and subsidies?

A question comes up almost every time a homeowner in Montérégie considers a MIDEA central heat pump: how much financial assistance will they receive?

The MIDEA document provided for this project gives the performance specifications for the product line, but it alone does not confirm the Quebec eligibility of a specific match for a subsidy.

This distinction is important.

To properly verify financial assistance, it is necessary to know the exact model numbers of the indoor and outdoor units, find the corresponding certified match, and apply the program rules in effect at the time of installation.

We therefore avoid announcing a subsidy amount simply because the unit bears the name EVOX G3.

At AirGreen, the proper method is to verify the exact combination proposed to the customer.

The proximity of the window also deserves serious technical consideration

The visible installation in Elgin is located directly beneath a large window.

This type of placement requires considering several factors: the manufacturer's clearances, air discharge, access for service, and indoor acoustic comfort.

An Inverter heat pump generally operates progressively rather than with systematic starts at full power. Despite this, every outdoor unit has a fan and a compressor.

The quality of the supports, the leveling, and how the unit is connected to the building are therefore important for limiting vibration transmission.

This is particularly true when a unit is installed directly against a home's structure rather than on an independent base.

Future maintenance was considered from the moment of installation

We always think about the technician who will need to service the unit several years after installation.

It must be possible to access the service panel, inspect the heat exchanger, clean the surfaces, measure electrical parameters and check the refrigerant circuit.

An installation positioned extremely close to a fence or surrounded by vegetation quickly becomes difficult to maintain.

In this Elgin installation, the front panel remains highly accessible. The owner will simply need to continue controlling the growth of nearby vegetation to preserve this accessibility.

What we take away from this MIDEA EVOX G3 installation in Elgin

This installation clearly shows why choosing a central heat pump should never be reduced to selecting a brand and tonnage.

The photo reveals several practical decisions: installation on wall brackets, substantial clearance above the ground, positioning beneath a window, vegetation nearby, unobstructed front-facing air discharge and accessible electrical disconnect.

The technology behind this outdoor unit goes much further: Inverter compressor for cold climates, operation rated down to -30 °C, R-454B refrigerant, modular indoor unit, adaptive airflow, communicating control options and various tonnages.

But these features only have value when the system is properly integrated into the building.

At AirGreen, we work precisely at the point where the machine meets the home: capacity selection, outdoor placement, clearances, refrigerant lines, electrical supply, ductwork, airflow, filtration, controls and auxiliary heating.

It is this comprehensive view of the project that allows an installation to maintain its performance long after our team has left.

We install and replace MIDEA EVOX G3 central heat pumps in Elgin and Montérégie, as well as throughout Greater Montreal, including Montreal, Laval, Longueuil, the South Shore and the North Shore. Before proposing a configuration, we can assess the home, its ductwork, electrical supply and site constraints so that the selected solution genuinely suits the building.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

    1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
    2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
    3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
    4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
    5. The outdoor unitOn a level base, raised above the snow, with free space all around.
    6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
    7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
    8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
    9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: central heat pump, indoor module and ducts

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

    2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

    3. A shut-off switch near the outdoor unit isolates it safely for service.

    4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

    5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

    6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

    7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

    8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment