Project

Installation of a MIDEA EVOX G3 central heat pump in Très-Saint-Rédempteur, Montérégie

At Très-Saint-Rédempteur, AirGreen installs a MIDEA EVOX G3 central heat pump on wall brackets, near an existing hedge: heating down to -30 °C, R-454B, inverter, airflow, and detailed HVAC installation.

By AirGreen Climatisation & Chauffage Admin16 min read
Installation of a MIDEA EVOX G3 central heat pump in Très-Saint-Rédempteur, Montérégie
Installation of a MIDEA EVOX G3 central heat pump in Très-Saint-Rédempteur, Montérégie
–chapters in this story
16 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: central heat pump, indoor module and ducts

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

  2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

  3. A shut-off switch near the outdoor unit isolates it safely for service.

  4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

  5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

  6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

  7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

  8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

The job

A central installation adapted to Quebec’s climate and the real-world constraints of an existing home

In Très-Saint-Rédempteur, we completed this MIDEA EVOX G3 central heat pump installation at a residence where several outdoor elements had to be considered simultaneously: brick wall, foundation, mature vegetation, downspout, existing electrical supply, and available space around the equipment.

The site photograph shows an installation that appears relatively simple once completed: a MIDEA outdoor unit properly aligned with the facade, installed on elevated wall brackets, with its electrical disconnect placed nearby. However, this type of result requires precise planning.

The heat pump’s placement directly affects its operation during the winter, access for HVAC maintenance, airflow quality, and the ease of future service work. For this installation in Très-Saint-Rédempteur, we therefore worked as much on integrating the unit with the building as on connecting the system itself.

An outdoor location where every existing element mattered

To the left of the outdoor unit, there is a mature conifer hedge. On the right is the electrical disconnect, while a downspout runs vertically down the facade above the installation.

This type of environment requires a much more thoughtful approach than simply “finding a place” for the heat pump.

We need to maintain several clearances:

  • in front of the large front fan;
  • around the coil;
  • under the heat pump for defrosting;
  • near the service panel;
  • around the electrical disconnect;
  • between the unit and the vegetation.

The hedge shown in the photo is one feature that will need to be monitored over the years. Vegetation that appears sufficiently far away at the time of installation can gradually move closer to the coil.

We therefore recommend keeping the branches trimmed to preserve airflow and access to the side of the unit.

Why we raised the MIDEA EVOX G3

The heat pump is installed on two metal brackets secured to the foundation, rather than directly on a ground-level slab.

For a central heat pump used during the winter, this additional height is particularly important.

In heating mode, the outdoor heat exchanger can accumulate frost. The system then periodically runs a defrost cycle. The resulting water must be able to drain beneath the unit without quickly forming a mass of ice directly against the chassis.

The elevation also helps reduce the risk of snow accumulated around the house quickly reaching the lower part of the unit.

On a job site in Très-Saint-Rédempteur, where the system must operate through real periods of Quebec cold, we want to keep this space beneath the machine from day one.

A horizontal-discharge outdoor unit

The large front fan is one of the most visible elements of the EVOX G3.

Midea describes this platform as using a horizontal discharge design, combined with a vertical heat exchanger. According to the documentation, this architecture is intended to provide more uniform airflow across the entire heat exchanger.

This geometry also makes it possible to maintain a relatively shallow profile against the building.

In this installation, the fan is directed toward an open area. No secondary wall or decorative screen is immediately in front of the grille.

This is important because a horizontal air discharge needs space to prevent the discharged air from returning directly toward the heat exchanger.

A central heat pump designed to operate down to -30 °C

The MIDEA EVOX G3 Extreme Heat was developed specifically for cold climates.

The documentation provided by Midea indicates continuous operation down to -30 °C. It also mentions up to 100% heating capacity at -25 °C, with a COP of up to 1.9 under the reference conditions presented by the manufacturer.

For an installation in Très-Saint-Rédempteur, this operating range is particularly relevant.

We do not choose a central heat pump solely based on its performance when temperatures are mild. We are mainly interested in what it can still deliver when temperatures become truly wintry.

The brochure explains that, when the system operates in extremely cold conditions, the compressor uses an intermediate-temperature vapor supply to increase the total amount of compressed refrigerant and support heating.

Operation down to -30 °C does not mean that supplemental heating is completely unnecessary

However, two concepts must be distinguished.

The first is the minimum operating temperature of the heat pump.

The second is the amount of heat required to maintain a given home at the desired temperature.

A very well-insulated home may require much less capacity than an older house with several large windows, air leaks, or high ceilings.

We therefore never consider the figure of -30 °C a guarantee that the heat pump will cover all the building's heat losses on its own in every situation.

The right approach is to size the entire system.

The EVOX G3 range covers several different capacities

The EVOX G3 is not a single heat pump with one fixed capacity.

The documentation presents a range of systems from 18,000 to 54,000 BTU/h in cooling, with different performance levels depending on the indoor and outdoor unit combinations.

Midea announces values for this family that can reach:

  • 19 SEER2;
  • 12.5 EER2;
  • 10.8 HSPF2;
  • COP of 2.14 at 5 °F, or approximately -15 °C.

The brochure's technical table shows configurations of 18,000, 24,000, 30,000, 36,000, 48,000, and 54,000 BTU/h, among others.

The photo of our project in Très-Saint-Rédempteur does not allow us to reliably read the unit's complete model number. We therefore do not artificially assign it a specific capacity.

To confirm the exact capacity of an installation, we always use the outdoor unit model and the indoor unit model.

Why sizing remains essential even with an inverter heat pump

An inverter central heat pump offers more modulation than a traditional fixed-capacity system.

That does not mean, however, that sizing becomes secondary.

We check, in particular:

  • the building's heating load;
  • the area actually served;
  • the insulation level;
  • the windows;
  • the airtightness;
  • the orientation of the house;
  • the ductwork capacity;
  • the available electrical capacity;
  • the potential need for supplemental heating.

A machine that is far too large may operate in a less favorable range for much of the year.

Conversely, a unit that is too small may require more supplemental heating during periods of extreme cold.

The goal, therefore, is to choose a MIDEA central heat pump that truly matches the building.

Behind the outdoor heat pump: the ductwork, indoor unit, and settings that determine actual comfort

A platform designed to facilitate central system replacements

The EVOX G3 was designed with several useful features when replacing an old furnace or an older central heat pump.

Midea indicates that the indoor unit can accommodate 115 V and 208/230 V power supplies depending on the configuration. The documentation also mentions cabinet widths of 14.5 to 21.5 inches, intended to correspond more easily to the dimensions of many existing furnaces.

This compatibility can limit certain major modifications in a mechanical room.

However, this does not mean that no adaptations are required.

We must always check:

  • the return air;
  • duct transitions;
  • the plenum;
  • condensate drainage;
  • access to the filter;
  • the power supply;
  • service clearances.

Six possible configurations for the air handler

Midea also presents a modular interior design that allows six installation orientations.

According to the documentation, the unit can be configured, among other ways, as follows:

  • upward discharge;
  • downward discharge;
  • right horizontal;
  • left horizontal;
  • “low-boy” configurations suited to tight spaces.

The modular design is also intended to facilitate moving the unit into difficult-to-access areas such as certain basements or attics.

For a renovation, this flexibility can genuinely simplify the work.

Airflow: one of the most underestimated elements of a central system installation

A central heat pump may deliver excellent performance on paper and still produce mediocre results if air does not circulate properly through the ductwork.

Midea equips the EVOX G3 with its Computational Constant Airflow 2.0 technology.

The documentation shows adaptability up to 1.2 in. of water column static pressure in the illustrated examples, as well as up to 60 air-flow adjustment levels.

The fan can therefore adjust its operation to different system conditions.

However, this capacity remains an adjustment tool.

It does not replace properly sizing the ductwork.

Poor return airflow does not become acceptable just because the fan is more advanced

An ECM motor can increase its effort to maintain airflow.

But if the return is too small, if the filter is too restrictive, or if several ducts are severely restricted, the underlying cause must be corrected.

At AirGreen, we therefore seek to obtain a system that operates with reasonable static pressure, rather than forcing the fan to compensate constantly for an inadequate duct network.

MERV 13 filtration available in several sizes

Midea documentation indicates compatibility with 1-, 2-, and 4-inch MERV 13 filters in the filtration module provided for this purpose.

This type of filtration can capture more dust, pollen, particles, and pet dander.

For the homeowner, this can be an appealing improvement to the home's air filtration.

But we always consider the filter size and system airflow simultaneously.

A small, highly restrictive filter can become a bottleneck.

The objective is therefore to combine filtration quality and low air resistance.

Auxiliary heating can reach 25 kW depending on the configuration

The brochure also provides for multistage auxiliary electric heating kits that can reach 25 kW, depending on the selected configuration.

Auxiliary heating remains relevant in our climate.

It can come into operation when the home's heat loss temporarily exceeds the available capacity of the heat pump.

It can also serve as backup under certain extreme conditions.

However, we seek to avoid activating it unnecessarily early.

A good control strategy should allow the heat pump to do as much of the work as reasonably possible before adding electric resistance.

Control options suited to renovations

Midea indicates that the EVOX G3 can operate with several communication strategies.

The documentation notably mentions:

  • the protocol 485;
  • 24 V thermostats;
  • certain wireless communication options between system components.

The manufacturer also presents its communicating thermostat and the SmartHome app, which can be used to manage schedules, comfort, certain consumption information, and diagnostic functions.

This flexibility is useful when old thermostat wiring already exists in the house and replacing it would be complicated.

R-454B at the heart of this new generation of systems

The MIDEA EVOX G3 uses R-454B refrigerant.

Midea indicates a global warming potential of 466 for this A2L refrigerant.

For an HVAC installation, this change has practical consequences.

Technicians must use methods and equipment suited to R-454B systems during:

  • refrigerant connection;
  • leak testing;
  • vacuuming;
  • commissioning;
  • future service work.

This is therefore not merely an environmental feature mentioned in a brochure: it directly influences how the installation must be carried out.

A detail visible in the photo: the electrical disconnect is accessible

To the right of the outdoor unit, we can clearly see the DiversiTech electrical disconnect enclosure.

Its location near the heat pump allows for an easily identifiable local disconnect.

For maintenance and diagnostics, this accessibility is essential.

We want a technician to be able to isolate the equipment without having to look for a hidden device behind a hedge or in an inaccessible area.

The electrical conduit also follows a neat path along the wall.

The pipe visible beneath the unit highlights the importance of drainage

Under the heat pump, we can also see a small pipe descending toward the ground.

On a central installation, we must manage several potential sources of water: condensate, outdoor defrost water and, depending on the configuration, drainage from the indoor unit.

The water must be directed so that it does not create a problem elsewhere.

Drainage often seems secondary when a heat pump is sold, but it quickly becomes important when a system operates day after day.

Vegetation must remain under control

The hedge to the left of the heat pump is probably the most important visible outdoor maintenance point in this photo.

We recommend trimming it periodically.

An outdoor coil that begins to be covered or surrounded by branches can:

  • receive less air;
  • accumulate more debris;
  • become more difficult to clean;
  • make access more difficult during a repair.

It is better to plan for this growth from the start.

What we avoid on an installation like the one in Très-Saint-Rédempteur

Installing the heat pump too low

This reduces snow clearance and makes it easier for ice to form beneath the unit.

Enclosing the unit between vegetation and a decorative screen

The fan needs an unobstructed air discharge.

Neglecting the ductwork

An excellent outdoor heat pump will never fully compensate for an undersized return or poorly designed air distribution.

Choosing a tonnage simply because the old unit had the same capacity

The home’s needs must be assessed.

Assuming that a maximum value for the range applies automatically

Values such as 19 SEER2 or 10.8 HSPF2 are range maximums, not figures applicable to all EVOX G3 combinations.

What about eligibility for financial assistance?

The Midea brochure indicates that the range exceeds certain ENERGY STAR specifications in the context presented by the manufacturer.

However, the document provided alone does not make it possible to confirm this Très-Saint-Rédempteur installation’s exact eligibility for a Quebec subsidy.

To do this, it is necessary to know the exact combination of the indoor and outdoor units, as well as the certification applicable to the program concerned.

At AirGreen, we therefore prefer to verify model numbers and certified references before announcing a financial assistance amount.

A discreet installation that conceals a great deal of technical work

At first glance, this MIDEA EVOX G3 installed in Très-Saint-Rédempteur seems to be simply mounted against the foundation.

But the quality of a central installation is measured above all by the many elements that are not immediately noticeable.

The heat pump is elevated to better handle winter conditions. Its front fan remains unobstructed. The electrical disconnect is accessible. Vegetation can be maintained without moving the unit. The indoor duct network must be adapted to the required airflow. The air handler, filtration, thermostat, and auxiliary heating must all be adjusted as a single system.

The EVOX G3 offers an interesting platform thanks to its advertised operation down to -30 °C, inverter technology, R-454B refrigerant, modular indoor unit, and advanced airflow control functions.

Our work at AirGreen consists of turning these technical features into an installation that suits the actual residence.

It is this same approach that we apply to our MIDEA central heat pump installations in Très-Saint-Rédempteur, Rigaud, Vaudreuil-Dorion, Hudson, Montréal, Laval, Longueuil, on the South Shore and on the North Shore: proper sizing, accessible installation, attention to Quebec winters, and commissioning of the complete system.

The unit

The unit on this job, in figures

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Midea EVOX G3 · 1.5 tons14,70018,600−30 °C: 11,8002.1219.010.1$1,764
Midea EVOX G3 · 2 tons20,80020,600−30 °C: 12,1002.1418.610.0$2,496
Midea EVOX G3 · 2.5 tons24,00033,200−30 °C: 17,9001.9717.210.8$2,880
Midea EVOX G3 · 3 tons33,00037,400−30 °C: 27,6001.918.010.0$3,960
Midea EVOX G3 · 4 tons39,50048,000−30 °C: 27,2002.017.59.5$4,740
Midea EVOX G3 · 5 tons45,00054,000−30 °C: 37,3001.917.59.5$5,400

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

  1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
  2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
  3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
  4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
  5. The outdoor unitOn a level base, raised above the snow, with free space all around.
  6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
  7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
  8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
  9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).