Installation of a Fujitsu AIRSTAGE Aquila XLTH dual-zone heat pump in L’Île-Bizard–Sainte-Geneviève, Montreal
In L’Île-Bizard–Sainte-Geneviève, AirGreen installs a Fujitsu Aquila XLTH dual-zone R32 heat pump on anti-vibration mounts to heat and cool two independent spaces.
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The article, chapter by chapter
A precisely installed multi-zone solution in a residential side passage
This installation in L’Île-Bizard–Sainte-Geneviève perfectly illustrates the type of project in which the quality of the work depends as much on choosing the right dual-zone heat pump as on how the outdoor unit is integrated into the building. The owner wanted better temperature control in two separate spaces without adding multiple outdoor units around the residence.
We therefore installed a Fujitsu AIRSTAGE Aquila XLTH heat pump, configured to serve two zones. A single outdoor unit can therefore provide heating and cooling for two rooms or areas of the house, each controlled by its own indoor unit and remote control.
The photograph taken during our work shows several important features of this installation:
- the outdoor unit is positioned in a relatively narrow side passage;
- the exterior cladding of the house is vinyl;
- the heat pump rests on a rigid structure located above ground level;
- anti-vibration mounts are visible beneath all four support points;
- the proximity of a basement window and the foundation was taken into consideration;
- the clearance in front of the fan remains unobstructed;
- the unit uses R32 refrigerant, clearly indicated on the front panel;
- The unit was installed in a way that preserves access to the service panel.
The gloves and documents temporarily placed on the unit show that the photo was taken during the final stage of the installation, before the worksite was fully cleaned and the system was handed over to the customer.
Why a dual-zone heat pump was suitable for this residence
In a house, two rooms of similar size may have very different heating and cooling needs. A room with many windows, exposed to afternoon sun, may accumulate a great deal of heat in summer. A bedroom located in another part of the building, on the other hand, may maintain a more stable temperature and require less air conditioning.
In winter, the situation can be reversed. A room located above a less-heated space, near an exterior wall, or exposed to prevailing winds may lose more heat than a central room.
With a Fujitsu dual-zone heat pump, each space has its own air-distribution point and setpoint temperature. For example, occupants can keep a bedroom at a lower temperature overnight while maintaining more warmth in a living area.
This zoning offers several advantages:
- a temperature better suited to how each room is used;
- less reliance on the natural movement of air between spaces;
- a single outdoor unit for two indoor units;
- a more discreet outdoor installation;
- power modulation according to actual demand;
- a reduced need to operate all zones at the same intensity.
According to Fujitsu documentation, H-series AIRSTAGE multi-zone systems can power several types of indoor units, including wall-mounted units, slim duct units, compact cassettes, and certain ducted units. Each indoor unit can be controlled independently, although the system as a whole operates in heating or cooling mode, not both modes simultaneously.
Choosing the outdoor location: a determining factor
The outdoor unit’s placement should never be decided solely based on where it seems to fit. In this project in L’Île-Bizard–Sainte-Geneviève, we had to work with a space between the house wall and the paved walkway.
The heat pump is located near the foundation, below the main level of the exterior cladding and near a basement opening. We maintained sufficient clearance in front of the fan so that air could be expelled without immediately encountering a wall, fence, or other obstacle.
Insufficient clearance in front of the unit can result in:
- recirculation of discharged air;
- reduced performance;
- increased pressure on the fan;
- more noise;
- faster accumulation of snow or debris;
- difficult access for HVAC maintenance.
The side containing the connections and technical panel must also remain accessible. During a future service call, the technician must be able to check the pressures, inspect the electrical connections, check the refrigerant connections, and access the internal components without having to move the equipment.
An installation on anti-vibration supports
The photo shows anti-vibration pads installed beneath the outdoor unit. These components are placed between the heat pump base and its support structure to limit vibration transmission.
This precaution is particularly important when the unit is installed near an exterior wall, a basement window, or an occupied room. Even a modern, well-designed appliance generates slight vibration from the compressor and fan.
An installation without adequate insulation can transmit this vibration:
- to the foundation;
- to the exterior cladding;
- to wooden structures;
- to the refrigeration lines;
- inside the house.
We also check that the unit is perfectly stable. All four support points must support the heat pump evenly. A unit that is tilted or placed on an unstable surface may produce additional vibrations and complicate water drainage during defrost cycles.
Ground and defrost water management
The side passage visible in the photo consists of gravel and concrete slabs. This configuration requires particular attention to water management.
In heating mode, the outdoor heat exchanger becomes cold and may accumulate frost. The heat pump then periodically initiates a defrost cycle. The resulting water must be able to drain beneath the unit without forming a mass of ice that could rise toward the chassis.
Poor ground preparation can result in:
- water accumulating beneath the heat pump;
- the formation of a sheet of ice;
- gradual shifting of the base;
- obstruction of the lower openings;
- premature deterioration of certain components;
- a slipping hazard in the passageway.
In this project, the unit is kept above the ground using rigid supports and anti-vibration blocks. This elevation creates useful space beneath the appliance and reduces direct contact with moisture, leaves, and small debris.
R32 refrigerant and appropriate installation practices
The label visible on the front confirms that this Fujitsu heat pump operates with R32This refrigerant is used in several newer appliances because of its thermodynamic performance and lower global warming potential than R410A.
However, R32 has characteristics that require installation using the appropriate tools and methods. In particular, we must comply with the requirements related to:
- to refrigeration fittings;
- to pressure testing;
- to leak detection;
- to pulling a vacuum;
- to refrigerant recovery;
- to workspace ventilation;
- to circuit protection.
Pulling a vacuum is an essential step. It is not enough to run a pump for a few minutes. We must remove the air and moisture present in the lines before opening the service valves. Residual moisture can react with the compressor oil, impair system operation, and reduce its lifespan.
An upgrade that protects long-term operation
The photographed unit is installed horizontally and stably. This leveling may seem simple, but it has direct consequences for operation.
An improperly leveled heat pump can:
- vibrate more;
- produce irregular noises;
- drain defrost water less effectively;
- place an uneven load on its support points;
- gradually shift the lines and connections;
- complicate future maintenance.
Before commissioning, we therefore check the level in several directions and confirm that the base cannot tip under the effect of the weight, vibrations, or freeze-thaw cycles.
The Fujitsu Aquila XLTH for personalized comfort
A multizone range suited to different configurations
Fujitsu documentation lists Aquila outdoor units rated at 18,000, 24,000, 36,000, and 45,000 BTU/h that can be connected to two, three, four, or five indoor units, depending on the model selected and the permitted combinations. The outdoor unit designed for two zones can accommodate several indoor-unit combinations, including 7,000 + 7,000 BTU, 9,000 + 9,000 BTU, 9,000 + 12,000 BTU, or 12,000 + 12,000 BTU, according to the manufacturer’s technical tables.
The exact capacity installed at this site cannot be read with sufficient precision from the photograph. We therefore do not infer it from the appearance of the unit alone. The precise model, the capacities of the indoor units, and the selected combination must always be confirmed using the nameplates and project documents.
This rigor helps avoid a common mistake: assuming a heat pump’s capacity based on the physical size of its cabinet. Several models use very similar chassis despite having different capacities and performance levels.
Sizing involves more than simply adding the BTUs
In a dual-zone configuration, it is tempting to simply add the nominal capacity of the two indoor units. This method is incomplete.
Sizing must take into account:
- of the building’s heat loss;
- of the wall and attic insulation;
- of the quality of the doors and windows;
- of solar exposure;
- of the actual area of each zone;
- of the ceiling height;
- of how frequently the rooms are used;
- of the line-set length;
- of the available capacity at low temperatures;
- of the simultaneous operation of both zones.
Fujitsu indicates in its tables that certain combinations may exceed 100% of the nominal connection capacity. However, the manufacturer specifies that this excess does not increase the outdoor unit’s total heating or cooling capacity. The available capacity is distributed among the indoor units according to demand.
An approved combination is therefore not automatically an ideal selection for every residence. The manufacturer recommends using its selection software to validate the system's actual capacity under the project's conditions.
Heating in cold weather
The Aquila versions designed for cold climates are suited to Quebec winters. The H-series documentation indicates that CTEB units can continue operating in heating mode down to -26 °C. It also mentions the use of an inverter compressor, which modulates its operation according to the required load.
It is important to understand that a minimum operating temperature does not necessarily correspond to a constant maximum capacity. As with all heat pumps, heating capacity varies according to the outdoor temperature.
We therefore analyze the capacity produced at low temperatures rather than looking only at the nominal BTU rating indicated in the system name.
Depending on the building's needs, the heat pump can work with:
- electric baseboards;
- an existing heating system;
- convector heaters;
- another backup heat source;
- a control strategy suited to periods of extreme cold.
Two independent zones, but one shared mode
Each indoor unit can have its own setpoint temperature. One zone can therefore request 21 °C while the other is set to 19 °C. The compressor adjusts its output and distributes capacity according to demand.
However, both zones must operate in the same general mode. In practice:
- both can provide heating;
- both can provide cooling;
- one zone can be turned off while the other is operating;
- they cannot provide heating and cooling simultaneously.
We explain this operation to the owner when handing over the system. This step reduces service calls caused by conflicting settings on the remote controls.
Mistakes to avoid when installing a multi-zone system
Pairing the wrong cable with the wrong refrigerant circuit
Each indoor unit must correspond to the correct line set and communication connection. Reversing them can cause inconsistent responses: the control for one room activates the circuit associated with another unit.
We identify the circuits during installation and test each zone separately before commissioning the system.
Damaging the exterior siding
The vinyl siding visible on this residence must be handled with care. Wall outlets, fixtures, and finish caps must be installed without crushing the siding or preventing its natural movement with temperature changes.
Placing the unit too close to the wall
The back of the heat pump must be able to draw in enough air. Insufficient clearance reduces airflow through the heat exchanger and may decrease performance.
Forgetting about future maintenance
A successful HVAC installation must be serviceable. We plan access to the electrical panel, service valves, heat exchanger, and removal screws.
Leaving the lines unprotected
The refrigerant lines and outdoor wiring must be protected from ultraviolet rays, moisture, impacts, and animals. A properly installed exterior finish protects the system and improves the building’s overall appearance.
Our Commissioning Procedure
Before handing over a Fujitsu dual-zone heat pump to the owner, we perform several checks:
- checking the stability and level of the outdoor unit;
- inspecting the vibration-isolating supports;
- checking the clearance around the heat exchanger and fan;
- leak testing of the refrigerant lines;
- a measured vacuum pull-down;
- validating the electrical connections;
- pairing each indoor unit with its circuit;
- testing each zone in cooling mode;
- testing each zone in heating mode;
- checking the condensate drains;
- checking supply-air temperatures;
- explanation of the remote controls and operating modes.
We also remind the customer to keep the outdoor area clean. Leaves, grass, and visible debris around the passage should be removed periodically so they do not obstruct the base or the heat exchanger.
An Installation Designed for L’Île-Bizard–Sainte-Geneviève
The properties of L’Île-Bizard–Sainte-Geneviève feature a variety of layouts: detached homes, more spacious lots, side passages, finished basements, and buildings constructed during different periods. These characteristics make an on-site assessment particularly important.
In this project, we integrated a Fujitsu outdoor unit into a limited space while maintaining:
- functional clearance in front of the fan;
- a stable base;
- protection against vibrations;
- access to the service panel;
- adequate separation from the ground;
- an installation adapted to the exterior siding.
The result is a Fujitsu Aquila XLTH dual-zone heat pump capable of providing customized comfort in two areas of the home with a single, well-integrated outdoor unit.
At AirGreen, we carry out this type of heat pump installation in Montreal, Laval, Longueuil, the North Shore and the South Shore. Each project is planned according to the building’s actual needs, the available space, the capacities authorized by the manufacturer, and the operating conditions specific to Quebec’s climate.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).