FUJITSU AIRSTAGE two-zone: two rooms, one outdoor unit.
Seven outdoor units take two heads, from 18,000 to 45,000 BTU/h. A surprise in Fujitsu’s tables: the 24,000 accepts 13 head pairs, more than the 36,000 (8) and the 45,000 (5). And the Aquila XLTH heats down to -26 °C.
Aquila, the Eagle
The constellation that gives Fujitsu’s multi-zone family its name, from catalogue coordinates. Fujitsu does not explain the choice.
Two rooms, two temperatures, one unit outside.
Seven facts from Fujitsu’s tables and sheets, the ENERGY STAR list and the LogisVert guide. Sources are at the bottom of the page.
The 18,000 BTU/h is the only Fujitsu multi-zone built for exactly two heads.
Bigger isn’t more flexible: the 24,000 accepts 13 head pairs, the 36,000 only 8 and the 45,000 only 5.
On the 36,000, every approved pair includes an 18,000 or a 24,000 head: two 9,000 heads are refused.
Two 9,000 heads on one 18,000 outdoor unit qualify for LogisVert; two separate 9,000 heat pumps don’t, because their outdoor units are under 12,000 BTU/h.
The Aquila XLTH 18,000 is certified for 22,000 BTU/h at 8 °C and at -15 °C alike.
The quietest outdoor unit in the family: 47 dB(A) in cooling for the Aquila XLTH 18,000, in the lab.
The Aquila 18,000 runs on a 15 A breaker, the smallest in the family.
Pick two heads, the tool finds the outdoor unit.
Switch outdoor units, remove a head, add another: the tool checks your pair against Fujitsu’s tables. Example: two 9,000 heads go on the 18,000 or the 24,000, not on the 36,000.
| Outdoor unit | Heads | Head sizes | Accepted total | Combinations | LogisVert |
|---|---|---|---|---|---|
| Aquila 18,000 | 2–2 | 7k · 9k · 12k · 15k | 14–24 k | 8 | $1,716 |
| Aquila 24,000 | 2–3 | 7k · 9k · 12k · 15k · 18k | 14–31 k | 23 | $1,872 |
| Aquila 36,000 | 2–4 | 7k · 9k · 12k · 15k · 18k · 24k | 25–46 k | 74 | $1,180 |
| Aquila 45,000 | 2–5 | 7k · 9k · 12k · 15k · 18k · 24k | 34–58 k | 171 | $3,720 |
| Aquila XLTH 18,000 | 2–2 | 7k · 9k · 12k · 15k | 14–24 k | 8 | $1,776 |
| Aquila XLTH 24,000 | 2–3 | 7k · 9k · 12k · 15k · 18k | 14–31 k | 23 | $1,944 |
| Aquila XLTH 36,000 | 2–4 | 7k · 9k · 12k · 15k · 18k · 24k | 25–46 k | 74 | $2,928 |
Fujitsu combination tables (FG8159A, rev. 2/2025).
A third room some day?
The 18,000 only has two ports. On the 24,000, 36,000 or 45,000, a port stays free: pick the unit, the tool shows which head can be added to each pair.
Aquila / XLTH 24,000
| Today | Head added later |
|---|---|
| 7,000 + 7,000 | + 7,000 · 9,000 · 12,000 · 15,000 |
| 7,000 + 9,000 | + 7,000 · 9,000 · 12,000 · 15,000 |
| 7,000 + 12,000 | + 7,000 · 9,000 · 12,000 |
| 7,000 + 15,000 | + 7,000 · 9,000 |
| 7,000 + 18,000 | no extra head |
| 9,000 + 9,000 | + 7,000 · 9,000 · 12,000 |
| 9,000 + 12,000 | + 7,000 · 9,000 |
| 9,000 + 15,000 | + 7,000 |
| 9,000 + 18,000 | no extra head |
| 12,000 + 12,000 | + 7,000 |
| 12,000 + 15,000 | no extra head |
| 12,000 + 18,000 | no extra head |
| 15,000 + 15,000 | no extra head |
8 of the 13 2-head combinations can take one more head later, per Fujitsu’s tables. LogisVert does not pay for adding a head: we plan for it from the start.
Aquila / XLTH 36,000
| Today | Head added later |
|---|---|
| 7,000 + 24,000 | + 7,000 · 9,000 · 12,000 · 15,000 |
| 9,000 + 24,000 | + 7,000 · 9,000 · 12,000 |
| 12,000 + 18,000 | + 7,000 · 9,000 · 12,000 · 15,000 |
| 12,000 + 24,000 | + 7,000 · 9,000 |
| 15,000 + 18,000 | + 7,000 · 9,000 · 12,000 |
| 15,000 + 24,000 | + 7,000 |
| 18,000 + 18,000 | + 7,000 · 9,000 |
| 18,000 + 24,000 | no extra head |
7 of the 8 2-head combinations can take one more head later, per Fujitsu’s tables. LogisVert does not pay for adding a head: we plan for it from the start.
Aquila 45,000
| Today | Head added later |
|---|---|
| 12,000 + 24,000 | + 7,000 · 9,000 · 12,000 · 15,000 · 18,000 |
| 15,000 + 24,000 | + 7,000 · 9,000 · 12,000 · 15,000 · 18,000 |
| 18,000 + 18,000 | + 7,000 · 9,000 · 12,000 · 15,000 · 18,000 |
| 18,000 + 24,000 | + 7,000 · 9,000 · 12,000 · 15,000 |
| 24,000 + 24,000 | + 7,000 · 9,000 |
5 of the 5 2-head combinations can take one more head later, per Fujitsu’s tables. LogisVert does not pay for adding a head: we plan for it from the start.
13 pairs on the 24,000, 5 on the 45,000.
A big outdoor unit needs big heads: the 36,000 wants at least one 18,000 or 24,000 head, the 45,000 at least one 24,000 or two 18,000s.
| Outdoor unit | 2 zones | 3 zones | 4 zones | 5 zones |
|---|---|---|---|---|
| Aquila 18,000 AOUH18KWAS2 | 8 combinations | – | – | – |
| Aquila 24,000 AOUH24KWAS3 | 13 combinations | 10 combinations | – | – |
| Aquila 36,000 AOUH36KWAS4 | 8 combinations | 35 combinations | 31 combinations | – |
| Aquila 45,000 AOUH45KWAS5 | 5 combinations | 38 combinations | 69 combinations | 59 combinations |
| Aquila XLTH 18,000 AOUH18KWAH2 | 8 combinations | – | – | – |
| Aquila XLTH 24,000 AOUH24KWAH3 | 13 combinations | 10 combinations | – | – |
| Aquila XLTH 36,000 AOUH36KWAH4 | 8 combinations | 35 combinations | 31 combinations | – |
Number of head combinations approved by Fujitsu, by number of rooms. Aquila and Aquila XLTH units of the same size share one table.
How many pairs per outdoor unit
The pair grid
| 7,000 | 9,000 | 12,000 | 15,000 | 18,000 | 24,000 | |
|---|---|---|---|---|---|---|
| 7,000 | 18k · 24k | 18k · 24k | 18k · 24k | 18k · 24k | 24k | 36k |
| 9,000 | 18k · 24k | 18k · 24k | 18k · 24k | 24k | 36k | |
| 12,000 | 18k · 24k | 24k | 24k · 36k | 36k · 45k | ||
| 15,000 | 24k | 36k | 36k · 45k | |||
| 18,000 | 36k · 45k | 36k · 45k | ||||
| 24,000 | 45k |
Read the row and column of your two heads: the cell gives the outdoor units that accept the pair (18k = 18,000 BTU/h). A dash: none.
Seven R-32 systems, six R-410A.
Tap a system: outdoor unit, possible heads, heat rated at -15 °C, efficiency and indicative LogisVert amount.
| Model | Heats down to | Max at -15 °C | SEER2 | HSPF2 | LogisVert | AHRI |
|---|---|---|---|---|---|---|
| Aquila 18,000 BTU/h, 2 zones | -15 °C | – | 22 | 10.5 | $1,716 | 215447685 |
| Aquila 24,000 BTU/h, 2 zones | -15 °C | – | 23 | 10.5 | $1,872 | 215447687 |
| Aquila 36,000 BTU/h, 2 zones | -15 °C | – | 22 | 10 | $1,180 | 215447689 |
| Aquila 45,000 BTU/h, 2 zones | -15 °C | 36,000 BTU/h | 22 | 10 | $3,720 | 215735280 |
| Aquila XLTH 18,000 BTU/h, 2 zones | -26 °C | – | 22 | 11 | $1,776 | 215447691 |
| Aquila XLTH 24,000 BTU/h, 2 zones | -26 °C | – | 23.5 | 11.5 | $1,944 | 215447693 |
| Aquila XLTH 36,000 BTU/h, 2 zones | -26 °C | 36,400 BTU/h | 22 | 10 | $2,928 | 215735282 |
| RLXFZ 18,000 BTU/h, 2 zones (R-410A) | -15 °C | – | 18 | 8.7 | $695 | 6998276 |
| RLXFZ 24,000 BTU/h, 2 zones (R-410A) | -15 °C | – | 18.5 | 8.7 | $705 | 6998279 |
| RLXFZ 45,000 BTU/h, 2 zones (R-410A) | -15 °C | – | – | – | $0 | – |
| RLXFZH 18,000 BTU/h, 2 zones (R-410A) | -26 °C | – | 21.5 | 9.6 | $1,704 | 8033584 |
| RLXFZH 24,000 BTU/h, 2 zones (R-410A) | -26 °C | – | 20 | 10 | $1,848 | 8033586 |
| RLXFZH 36,000 BTU/h, 2 zones (R-410A) | -26 °C | – | 20.5 | 9.5 | $2,568 | 8908615 |
The Aquila XLTH 18,000 keeps 22,000 BTU/h at -15 °C.
Tap a temperature: the bars show the maximum heat published by Fujitsu, the red tick the ENERGY STAR value rated with wall heads.
| Size | 8.3 °C | -8.3 °C | -15 °C | -26.1 °C |
|---|---|---|---|---|
| Aquila 18,000 | – | – | – | – |
| Aquila 24,000 | – | – | – | – |
| Aquila 36,000 | – | – | – | – |
| Aquila 45,000 | 50,000 BTU/h | 41,000 BTU/h | 36,000 BTU/h | – |
| Aquila XLTH 18,000 | – | – | – | – |
| Aquila XLTH 24,000 | – | – | – | 14,000 BTU/h |
| Aquila XLTH 36,000 | 42,000 BTU/h | 38,000 BTU/h | 36,400 BTU/h | 22,140 BTU/h |
Bars: maximum heat published by Fujitsu, when it is. Red tick: ENERGY STAR value rated with wall heads. At -8 °C the ENERGY STAR value is a part-load test: it can be lower than at -15 °C.
At -15 °C, how much of the 8 °C heat is left?
Aquila 18,000 or Aquila XLTH 18,000?
Same size, same head pairs. One is lower and makes do with a 15 A breaker; the other heats down to -26 °C and has a heated base pan.
| Aquila 18,000 | Aquila XLTH 18,000 | |
|---|---|---|
| Heats down to | -15 °C | -26 °C |
| Rated at -15 °C | 17,000 BTU/h | 22,000 BTU/h |
| Rated at 8 °C | 22,000 BTU/h | 22,000 BTU/h |
| SEER2 | 22 | 22 |
| HSPF2 | 10.5 | 11 |
| Heads | 2–2 | 2–2 |
| Max total line set | 50 m | 50 m |
| Breaker | 15 A | 20 A |
| Outdoor unit height | 716 mm | 884 mm |
| Outdoor weight | 45 kg | 53 kg |
| Outdoor sound, heating | 49 dB(A) | 49 dB(A) |
| Heated base pan | no | yes |
| Indicative LogisVert | $1,716 | $1,776 |
On a condo balcony or in a well-insulated house near Montréal, the Aquila 18,000 is often enough. In the country, or if the heat pump has to heat alone in deep cold, the Aquila XLTH 18,000 keeps 22,000 BTU/h rated at -15 °C. We discuss it during the visit.
Wall heads, ducted or a mix: three different ratings.
Switch between the three: efficiency, heat rated at -8 °C and the LogisVert amount change with the type of heads.
| Outdoor unit | Wall heads | Mixed | Ducted |
|---|---|---|---|
| Aquila 18,000 | SEER2 22 · HSPF2 10.5 · at -8 °C: 14,300 BTU/h · LogisVert $1,716 | SEER2 20.5 · HSPF2 10 · at -8 °C: 14,700 BTU/h · LogisVert $1,764 | SEER2 19 · HSPF2 9.5 · at -8 °C: 15,100 BTU/h · LogisVert $1,812 |
| Aquila 24,000 | SEER2 23 · HSPF2 10.5 · at -8 °C: 15,600 BTU/h · LogisVert $1,872 | SEER2 21 · HSPF2 10 · at -8 °C: 15,600 BTU/h · LogisVert $1,872 | SEER2 19.5 · HSPF2 9.5 · at -8 °C: 15,600 BTU/h · LogisVert $1,872 |
| Aquila 36,000 | SEER2 22 · HSPF2 10 · at -8 °C: 23,600 BTU/h · LogisVert $1,180 | SEER2 20.5 · HSPF2 9.5 · at -8 °C: 24,000 BTU/h · LogisVert $1,200 | SEER2 19 · HSPF2 9 · at -8 °C: 24,400 BTU/h · LogisVert $1,220 |
| Aquila 45,000 | SEER2 22 · HSPF2 10 · at -8 °C: 31,000 BTU/h · LogisVert $3,720 | SEER2 20.5 · HSPF2 9.5 · at -8 °C: 30,800 BTU/h · LogisVert $3,696 | SEER2 19 · HSPF2 9 · at -8 °C: 30,600 BTU/h · LogisVert $3,672 |
| Aquila XLTH 18,000 | SEER2 22 · HSPF2 11 · at -8 °C: 14,800 BTU/h · LogisVert $1,776 | SEER2 20.5 · HSPF2 10.5 · at -8 °C: 14,800 BTU/h · LogisVert $1,776 | SEER2 19 · HSPF2 10 · at -8 °C: 14,800 BTU/h · LogisVert $1,776 |
| Aquila XLTH 24,000 | SEER2 23.5 · HSPF2 11.5 · at -8 °C: 16,200 BTU/h · LogisVert $1,944 | SEER2 22 · HSPF2 11 · at -8 °C: 16,200 BTU/h · LogisVert $1,944 | SEER2 20.5 · HSPF2 10.5 · at -8 °C: 16,200 BTU/h · LogisVert $1,944 |
| Aquila XLTH 36,000 | SEER2 22 · HSPF2 10 · at -8 °C: 24,400 BTU/h · LogisVert $2,928 | SEER2 20.5 · HSPF2 9.5 · at -8 °C: 23,800 BTU/h · LogisVert $2,856 | SEER2 19 · HSPF2 9 · at -8 °C: 23,400 BTU/h · LogisVert $2,808 |
Each outdoor unit has three ENERGY STAR and AHRI certificates. AirGreen’s products ship with wall heads: the first certificate applies. The mixed certificate is the average of the other two.
One head in the basement, the other upstairs?
Possible, within Fujitsu’s limits: 25 m per line, 15 m of height between the outdoor unit and a head, 10 m between the two heads. Drag the sliders.
| Model | Max length | Max height | Pre-charge | Minimum |
|---|---|---|---|---|
| Aquila 18,000 | 25 m | 15 m | 30 m | 5 m |
| Aquila 24,000 | 25 m | 15 m | 30 m | 5 m |
| Aquila 36,000 | 25 m | 15 m | – | 5 m |
| Aquila 45,000 | 25 m | 15 m | – | 5 m |
| Aquila XLTH 18,000 | 25 m | 15 m | 30 m | 5 m |
| Aquila XLTH 24,000 | 25 m | 15 m | – | 5 m |
| Aquila XLTH 36,000 | 25 m | 15 m | – | 5 m |
All lines together: the maximum per unit
A quiet head, a more present outdoor unit.
Wall heads from 21 dB(A) on quiet speed; the outdoor unit, from 47 to 56 dB(A) depending on size and mode. Fujitsu lab measurements.
| Model | Indoor, quiet speed | Indoor, high speed | Outdoor unit |
|---|---|---|---|
| Aquila 18,000 | 21 dB(A) | – | 49 dB(A) |
| Aquila 24,000 | 21 dB(A) | – | 52 dB(A) |
| Aquila 36,000 | 21 dB(A) | – | 56 dB(A) |
| Aquila 45,000 | 29 dB(A) | – | 56 dB(A) |
| XLTH 18,000 | 21 dB(A) | – | 49 dB(A) |
| XLTH 24,000 | 21 dB(A) | – | 52 dB(A) |
| XLTH 36,000 | 21 dB(A) | – | 56 dB(A) |
| RLXFZ 18,000 | – | – | 49 dB(A) |
| RLXFZ 45,000 | – | – | 55 dB(A) |
| RLXFZH 24,000 | – | – | 52 dB(A) |
Levels published by Fujitsu, measured in a lab; at home, the room, the furniture and the distance change what you hear. Scale: Government of Québec reference points.
From $1,180 to $3,720 with two wall heads.
The amount follows the outdoor unit, not the number of heads. Two separate small 9,000 wall units get nothing: each is under the 12,000 BTU/h minimum. The same heads on an Aquila 18,000: $1,716.
| Model | Indicative amount | Calculation |
|---|---|---|
| Aquila 18,000 BTU/h, 2 zones | $1,716 | 14,300 BTU/h ÷ 1,000 × $120 = $1,716 |
| Aquila 24,000 BTU/h, 2 zones | $1,872 | 15,600 BTU/h ÷ 1,000 × $120 = $1,872 |
| Aquila 36,000 BTU/h, 2 zones | $1,180 | 23,600 BTU/h ÷ 1,000 × $50 = $1,180 |
| Aquila 45,000 BTU/h, 2 zones | $3,720 | 31,000 BTU/h ÷ 1,000 × $120 = $3,720 |
| Aquila XLTH 18,000 BTU/h, 2 zones | $1,776 | 14,800 BTU/h ÷ 1,000 × $120 = $1,776 |
| Aquila XLTH 24,000 BTU/h, 2 zones | $1,944 | 16,200 BTU/h ÷ 1,000 × $120 = $1,944 |
| Aquila XLTH 36,000 BTU/h, 2 zones | $2,928 | 24,400 BTU/h ÷ 1,000 × $120 = $2,928 |
| RLXFZ 18,000 BTU/h, 2 zones (R-410A) | $695 | 13,900 BTU/h ÷ 1,000 × $50 = $695 |
| RLXFZ 24,000 BTU/h, 2 zones (R-410A) | $705 | 14,100 BTU/h ÷ 1,000 × $50 = $705 |
| RLXFZ 45,000 BTU/h, 2 zones (R-410A) | $0 | – |
| RLXFZH 18,000 BTU/h, 2 zones (R-410A) | $1,704 | 14,200 BTU/h ÷ 1,000 × $120 = $1,704 |
| RLXFZH 24,000 BTU/h, 2 zones (R-410A) | $1,848 | 15,400 BTU/h ÷ 1,000 × $120 = $1,848 |
| RLXFZH 36,000 BTU/h, 2 zones (R-410A) | $2,568 | 21,400 BTU/h ÷ 1,000 × $120 = $2,568 |
Since November 26, 2025, only ENERGY STAR certified heat pumps qualify.
The outdoor unit must be at least 12,000 BTU/h nominal in cooling.
The grant never exceeds the purchase and installation cost, before taxes.
You apply no later than nine months after installation.
July 8, 2027
One system, one amount: the amount depends on the outdoor unit and its certificate, not on the number of heads. Adding a head later does not earn a second amount.
The R-410A two-zones.
They stay in AirGreen’s catalogue, with their own R-410A heads. Their LogisVert amount depends on the ENERGY STAR list: from $0 to $2,568 depending on the outdoor unit.
| Outdoor unit | Heads | Heats down to | ENERGY STAR | 15,000 head | Indicative LogisVert |
|---|---|---|---|---|---|
| RLXFZ 18,000 AOU18RLXFZ | 2 | -15 °C | standard | yes | $695 |
| RLXFZ 24,000 AOU24RLXFZ | 2–3 | -15 °C | standard | yes | $705 |
| RLXFZ 45,000 AOU45RLXFZ | 2–5 | -15 °C | not listed | no | $0 |
| RLXFZH 18,000 AOU18RLXFZH | 2 | -26 °C | cold climate | no | $1,704 |
| RLXFZH 24,000 AOU24RLXFZH | 2–3 | -26 °C | cold climate | no | $1,848 |
| RLXFZH 36,000 AOU36RLXFZH | 2–4 | -26 °C | cold climate | no | $2,568 |
R-410A generation: Fujitsu’s 2016 multi-zone brochure and the ENERGY STAR list, read October 8, 2026. The 15,000 R-410A head (ASU15RLS2) is not compatible with the units marked “no”, according to Fujitsu.
Good to know: according to Fujitsu, the RLXFZ 36,000 (AOU36RLXFZ1) takes three to four heads, so it does not appear in this two-head table.
What to know before choosing.
One mode at a time All heads on one outdoor unit heat together or cool together, according to Fujitsu.
Capacity is shared When every head calls, total capacity is the outdoor unit’s; what is unused goes to the rooms still calling.
Only the combinations in the tables Fujitsu approves specific head combinations; the tables are not for sizing, hence the home visit.
One system, one amount For LogisVert, one outdoor unit and its heads are one system; adding or replacing a single head is not eligible.
The right certificate Wall heads only: non-ducted certificate. All ducted: ducted certificate. A mix: mixed certificate.
The right match Fujitsu’s warranty excludes incorrect matching of units: we pick the heads from the tables.
The outdoor units, line by line.
| Aquila 18,000 | Aquila 24,000 | Aquila 36,000 | Aquila 45,000 | Aquila XLTH 18,000 | Aquila XLTH 24,000 | Aquila XLTH 36,000 | |
|---|---|---|---|---|---|---|---|
| Outdoor unit | AOUH18KWAS2 | AOUH24KWAS3 | AOUH36KWAS4 | AOUH45KWAS5 | AOUH18KWAH2 | AOUH24KWAH3 | AOUH36KWAH4 |
| Heads | 2–2 | 2–3 | 2–4 | 2–5 | 2–2 | 2–3 | 2–4 |
| Heats down to | -15 °C | -15 °C | -15 °C | -15 °C | -26 °C | -26 °C | -26 °C |
| Accepted heads total | 14,000–24,000 BTU/h | 14,000–31,000 BTU/h | 25,000–46,000 BTU/h | 34,000–58,000 BTU/h | 14,000–24,000 BTU/h | 14,000–31,000 BTU/h | 25,000–46,000 BTU/h |
| SEER2 | 22 | 23 | 22 | 22 | 22 | 23.5 | 22 |
| HSPF2 | 10.5 | 10.5 | 10 | 10 | 11 | 11.5 | 10 |
| Rated heat 8 / -8 / -15 °C | 22,000 / 14,300 / 17,000 | 24,000 / 15,600 / 19,200 | 36,400 / 23,600 / 24,000 | 48,000 / 31,000 / 36,000 | 22,000 / 14,800 / 22,000 | 25,000 / 16,200 / 25,200 | 36,400 / 24,400 / 36,400 |
| Cold climate | yes | yes | no | yes | yes | yes | yes |
| Heated base pan | no | no | no | no | yes | yes | yes |
| Max total line set | 50 m | 50 m | 70 m | 80 m | 50 m | 70 m | 70 m |
| Breaker | 15 A | 20 A | 25 A | 30 A | 20 A | 25 A | 35 A |
| Outdoor sound (cool / heat) | 48 / 49 dB(A) | 50 / 52 dB(A) | 54 / 56 dB(A) | 54 / 56 dB(A) | 47 / 49 dB(A) | 50 / 52 dB(A) | 54 / 56 dB(A) |
| Size (w×h×d) | 820×716×315 mm | 820×716×315 mm | 820×884×315 mm | 940×998×320 mm | 820×884×315 mm | 820×884×315 mm | 940×998×320 mm |
| Weight | 45 kg | 46 kg | 58 kg | 74 kg | 53 kg | 54 kg | 70 kg |
| AHRI no. (wall heads) | 215447685 | 215447687 | 215447689 | 215735280 | 215447691 | 215447693 | 215735282 |
| Indicative LogisVert | $1,716 | $1,872 | $1,180 | $3,720 | $1,776 | $1,944 | $2,928 |
Fujitsu submittal sheets and the ENERGY STAR list, read October 8, 2026. Ratings with wall heads.
What the two-zone tables tell.
The 24,000 accepts 13 head pairs, more than the 36,000 (8) and the 45,000 (5).
Source: FujitsuThe Aquila XLTH 18,000 is certified for 22,000 BTU/h at 8 °C and at -15 °C alike.
Source: ENERGY STARThe Aquila 18,000 runs on a 15 A breaker, the smallest in the family.
Source: FujitsuTwo 9,000 heads on one 18,000 outdoor unit qualify for LogisVert; two separate 9,000 heat pumps don’t.
Source: Hydro-QuébecThe best SEER2 of any Fujitsu multi-zone, 23.5, belongs to the Aquila XLTH 24,000, sold as a two-zone.
Source: ENERGY STAREven with both heads right next to the outdoor unit, a 36,000 or 45,000 needs at least 15 m of line set in total.
Source: FujitsuUp to 12 years on parts and compressor.
The longest tier needs online registration within 60 days and a Fujitsu Elite contractor. At AirGreen, both are done for you.
In Québec, the basic warranty needs no registration; the 10- and 12-year tiers do. Source: Fujitsu limited warranty statement (R-32).
We register your unit with Fujitsu, free, on time.
The condition for the 12-year tier. AirGreen is Elite Plus.
The warranty requires a licensed contractor. RBQ 5645-9605-01.
Fujitsu’s text excludes systems bought from an online retailer.
Fujitsu’s pairs, AirGreen’s choice.
Thirty-four pairs, seven outdoor units: the right system depends on your two rooms. AirGreen measures them, picks the pair, installs and registers the warranty.
What FUJITSU AIRSTAGE brings
- 34 pairsApproved by Fujitsu, all in the tool.
- Down to -26 °CWith the Aquila XLTH.
- From 15 AAquila 18,000 breaker.
- Up to 12 yearsParts and compressor, on Fujitsu’s conditions.
What AirGreen brings
- Elite Plus dealerThe highest level of the AIRSTAGE Elite program.
- Free home estimateWe measure and check the insulation and the location.
- Warranty registered for youWith Fujitsu, within 60 days.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: two comfortable rooms, on the smallest outdoor unit that does the job.
Recent installations, in photos.
Each article on our blog tells a real installation: the rooms, the outdoor unit and the lines.






Elite Plus: the highest level of the AIRSTAGE Elite program.
Fujitsu’s Japanese engineering, installed by an Elite Plus team across Montreal, Laval, Longueuil, the North Shore, the South Shore and Montérégie.
The highest level of the AIRSTAGE Elite program.
Our technicians take the manufacturer’s training on AIRSTAGE systems.
Vacuum, refrigerant settings, electrical hookup, set up for winter.
Manufacturer parts and Fujitsu technical support, wherever we install.
Free. We measure and check the insulation and the location.
The model, the size and the indicative LogisVert amount, in writing.
Vacuum, refrigerant, electrical, winter settings.
We register the unit with Fujitsu and help you with LogisVert.
What people ask us about two-zone systems.
No question matches. Call us at 514 316-2973.
The 18,000 BTU/h suits two small or medium rooms (7,000 to 15,000 heads). The 24,000 takes an 18,000 head. The 36,000 and 45,000 are for when one room needs an 18,000 or 24,000 head.
No. On the 36,000, Fujitsu only allows pairs that include an 18,000 or 24,000 head, for example 12,000 + 18,000.
Yes with a 24,000, 36,000 or 45,000, if the new combination is in Fujitsu’s tables. No with an 18,000, which takes two heads only.
Yes. The outdoor unit then sends its capacity to the room that is on.
No. Both heads heat together or cool together. Opposite needs call for two systems.
For an R-32 Aquila with wall heads: from $1,180 (standard Aquila 36,000) to $3,720 (Aquila 45,000). The amount depends on the outdoor unit and the installation date, not on the head sizes.
A heat pump whose outdoor unit is under 12,000 BTU/h nominal doesn’t qualify for LogisVert. A 9,000 + 9,000 two-zone on an 18,000 outdoor unit does, if it is ENERGY STAR certified.
The XLTH heats down to -26 °C and has a heated base pan. The standard model is rated down to -15 °C; it has no low-temperature cut-out, but its capacity isn’t tested below -15 °C.
The Aquila XLTH 18,000 is rated 47 dB(A) in cooling and 49 dB(A) in heating, measured in a semi-anechoic chamber. On site it can read a little higher.
Yes, if the two heads are within 10 m of height of each other, within 15 m of the outdoor unit and within 25 m of line set each.
From 15 A (Aquila 18,000) to 35 A (Aquila XLTH 36,000), on a dedicated 208/230 V circuit.
Related collections.
The whole FUJITSU multi-zone family, two to five rooms.
View the collectionMulti-zone3-zone multi-zoneA third room: 24,000, 36,000 or 45,000 BTU/h.
View the collectionR-32Altair 500Just one room: the same ASUH..KPAS heads as a single-zone system.
View the collectionWall unitsWall heat pumpsEvery single-zone FUJITSU wall heat pump.
View the collectionYour two-zone, installed by an Elite Plus team.
We come and see both rooms, pick the pair from Fujitsu’s tables and give you a clear quote with the indicative LogisVert amount.
Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump: hang up.
Sources checked on October 8, 2026
26 sources · show
- Fujitsu AIRSTAGE, airstagehvac.com/products/multi
- Fujitsu AIRSTAGE, airstagehvac.com/r32-2-3-4rooms/kwas
- Fujitsu AIRSTAGE, airstagehvac.com/r32-2-3-4rooms/kwah
- Fujitsu, submittal sheet 18KWAS2
- Fujitsu, submittal sheet 24KWAS3
- Fujitsu, submittal sheet 36KWAS4
- Fujitsu, submittal sheet 45KWAS5
- Fujitsu, submittal sheet 18KWAH2
- Fujitsu, submittal sheet 24KWAH3
- Fujitsu, submittal sheet 36KWAH4
- Fujitsu, brochure FG8159A
- Fujitsu, brochure FG2057B
- Fujitsu, brochure FG2057
- Fujitsu, product or archive page LEG
- Fujitsu AIRSTAGE, document pdf-fcus-pr-2016-fujitsu-36-000-multi-zone-xlth-01
- Fujitsu AIRSTAGE, document pdf-fcus-h-series-warranty-r32-202606
- ENERGY STAR, certified air-source heat pump list (dataset w7cv-9xjt)
- ENERGY STAR, program criteria
- Hydro-Québec, LogisVert residential participation guide, version 1.10
- Hydro-Québec, residential
- Government of Québec, mesure du bruit
- Government of Canada, heating cooling heat pump
- U.S. eCFR, section 429.16
- International Astronomical Union, star and constellation names
- airgreen.ca product sheets, read October 8, 2026
- AirGreen, “Nos réalisations” projects blog
Amounts shown are estimates; only Hydro-Québec confirms the grant. Manufacturer data is quoted “according to Fujitsu”.
The two-zone systems, right below.
Each product sheet gives the outdoor unit, the head pairs offered and the indicative LogisVert amount.