FUJITSU AIRSTAGE J-7S VRF systems: one outdoor unit, up to 12 rooms.
The J-7S is Fujitsu’s R-32 mini-VRF, at 2, 3 and 4 tons. A single outdoor unit feeds up to 5, 9 or 12 indoor units, with up to 120 m of total piping. It heats down to -26 °C, with no low-temperature lockout according to Fujitsu. For a condo, a plex or a small business.
One unit, many rooms
A single J-7S outdoor unit feeds up to 12 indoor units: wall units, cassettes, slim ducted units or air handlers.
One unit, up to 12 indoor units.
Seven facts from Fujitsu’s brochure and release and the ENERGY STAR list. Sources are at the bottom of the page.
One outdoor unit feeds up to 5 indoor units at 2 tons, 9 at 3 tons and 12 at 4 tons.
Up to 120 m of total piping, 50% more than the previous generation.
The outdoor unit can tuck under a window or below a balcony railing.
All three sizes are ENERGY STAR, Cold Climate and Most Efficient certified.
On the 3- and 4-ton units, the connected indoor capacity can range from 50% to 130% of the outdoor unit’s.
In 2017 the J-IIS range took 8 indoor units; the 4-ton J-7S takes 12.
The J-7S is a VRF heat pump: the whole system heats or cools at the same time.
One outdoor unit, up to 12 rooms.
Pick a size and add indoor units: the tool counts the units and compares the connected capacity with the 50 to 130% range Fujitsu publishes for the 3- and 4-ton.
| Size | Indoor units, at most | Connected capacity |
|---|---|---|
| 2 tons · 24,000 | 5 | not published |
| 3 tons · 36,000 | 9 | 50 to 130% |
| 4 tons · 48,000 | 12 | 50 to 130% |
Indicative indoor capacities: each family’s exact sizes and the branch limits are confirmed with Fujitsu’s technical manual, at design time.
2, 3 or 4 tons.
Tap a size: photo, sheet, efficiency and indicative LogisVert amount.
| Model | Heats down to | Max at -15 °C | SEER2 | HSPF2 | LogisVert | AHRI |
|---|---|---|---|---|---|---|
| J-7S 24,000 BTU/h, 1 indoor unit | -26 °C | 26,200 BTU/h | 22.2 | 11.3 | $2,088 | 216372779 |
| J-7S 36,000 BTU/h, 1 indoor unit | -26 °C | 36,400 BTU/h | 21.7 | 10.8 | $3,144 | 216372781 |
| J-7S 48,000 BTU/h, 1 indoor unit | -26 °C | 41,500 BTU/h | 20.2 | 10.2 | $4,296 | 216372783 |
Size and number of indoor units.
Our shop has one product per size and indoor-unit count. Filter by size.
| Item | What it does |
|---|---|
| J-7S 24,000 BTU/h, 1 indoor unit | AOUK024SSAN7 · up to 5 indoor units |
| J-7S 24,000 BTU/h, 2 indoor units | AOUK024SSAN7 · up to 5 indoor units |
| J-7S 24,000 BTU/h, 3 indoor units | AOUK024SSAN7 · up to 5 indoor units |
| J-7S 24,000 BTU/h, 4 indoor units | AOUK024SSAN7 · up to 5 indoor units |
| J-7S 24,000 BTU/h, 5 indoor units | AOUK024SSAN7 · up to 5 indoor units |
| J-7S 36,000 BTU/h, 1 indoor unit | AOUK036SSAN7 · up to 9 indoor units |
| J-7S 36,000 BTU/h, 2 indoor units | AOUK036SSAN7 · up to 9 indoor units |
| J-7S 36,000 BTU/h, 3 indoor units | AOUK036SSAN7 · up to 9 indoor units |
| J-7S 36,000 BTU/h, 4 indoor units | AOUK036SSAN7 · up to 9 indoor units |
| J-7S 36,000 BTU/h, 5 indoor units | AOUK036SSAN7 · up to 9 indoor units |
| J-7S 36,000 BTU/h, 6 indoor units | AOUK036SSAN7 · up to 9 indoor units |
| J-7S 36,000 BTU/h, 7 indoor units | AOUK036SSAN7 · up to 9 indoor units |
| J-7S 36,000 BTU/h, 8 indoor units | AOUK036SSAN7 · up to 9 indoor units |
| J-7S 36,000 BTU/h, 9 indoor units | AOUK036SSAN7 · up to 9 indoor units |
| J-7S 48,000 BTU/h, 1 indoor unit | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 2 indoor units | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 3 indoor units | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 4 indoor units | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 5 indoor units | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 6 indoor units | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 7 indoor units | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 8 indoor units | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 9 indoor units | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 10 indoor units | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 11 indoor units | AOUK048SSAN7 · up to 12 indoor units |
| J-7S 48,000 BTU/h, 12 indoor units | AOUK048SSAN7 · up to 12 indoor units |
From 4,000 BTU/h.
Wall units, compact cassettes, slim ducted units and air handlers, mixed on the same outdoor unit.
| Family | Type | Capacity |
|---|---|---|
| ASUA***KSA1 | Wall-mounted | 4,000 to 14,000 BTU/h |
| AUUA***KSA1 | Compact cassette | 4,000 to 18,000 BTU/h |
| ARUL***KSA1 | Slim ducted | 4,000 to 18,000 BTU/h |
| ARUX***KSA1 | Multi-position air handler | 12,000 to 60,000 BTU/h |
Families allowed by Fujitsu’s J-7S brochure (rev. 11/2025), mixed freely up to the unit’s maximum. Fujitsu’s page now shows KSA2 suffixes and more families: the shipped model is confirmed at quote time.
Down to -26 °C, no lockout.
Bars: the capacity at -15 °C published by ENERGY STAR. Red tick: the rated values, including the -8 °C one LogisVert uses. Fujitsu claims up to 89% capacity at -18 °C for the 2-ton.
| Size | -15 °C |
|---|---|
| J-7S 2 tons | 26,200 BTU/h |
| J-7S 3 tons | 36,400 BTU/h |
| J-7S 4 tons | 41,500 BTU/h |
At -8 °C the rated value is a part-load test: it is lower than the -15 °C one. ENERGY STAR values.
The J-7S is a VRF heat pump.
VRF heat pump (J-7S)
| What it is | A VRF heat pump, according to Fujitsu |
| The mode | The system heats or cools |
| Each room | Its own temperature |
| For whom | Condo, plex, small business |
ENERGY STAR lists the J-7S as a “mini or multi split” heat pump.
Heat recovery
| What it is | A heat-recovery VRF |
| The mode | Chosen room by room |
| It takes | Distribution boxes (RB units) |
| For whom | Buildings where some rooms heat while others cool |
Fujitsu describes heat recovery this way: “cooling and heating operation can be selected individually for each indoor unit.” That is not the J-7S; we discuss it at the estimate.
Below the railing, above the snow.
Fujitsu says the outdoor unit can tuck under a window or below a balcony railing. Its published dimensions: 998, 940 and 320 mm.
Fujitsu’s VRF installation manual calls for a raised support, higher than drifting snow.
Fujitsu recommends snow hoods and drift-prevention fencing, with a suitable air baffle.
Space is needed under the unit for ice from the defrost water.
Up to 120 m in total.
Maximum total piping length per Fujitsu’s brochure, or 393 ft: 50% more than the previous generation.
The farthest unit, the length after the first branch and the height differences are in Fujitsu’s technical manual; we check them at design time.
The J-7S uses 12% less refrigerant than the previous generation, according to Fujitsu. The factory charge is limited to 5.95 lb on all models.
Leak sensor built into the ducted units. Optional: a gas alarm kit and a shut-off valve kit that closes the piping if a leak is detected.
To be confirmed for each project.
LogisVert and VRF: Hydro-Québec’s guide does not name VRF. It covers residential buildings, with one complete system per dwelling: one outdoor unit and one or more indoor units. The amounts below follow the guide’s rule ($120 per 1,000 BTU/h at -8 °C); your project’s eligibility is confirmed with Hydro-Québec.
| Model | Indicative amount | Calculation |
|---|---|---|
| J-7S 2 tons | $2,088 | 17,400 BTU/h ÷ 1,000 × $120 = $2,088 |
| J-7S 3 tons | $3,144 | 26,200 BTU/h ÷ 1,000 × $120 = $3,144 |
| J-7S 4 tons | $4,296 | 35,800 BTU/h ÷ 1,000 × $120 = $4,296 |
Since November 26, 2025, only ENERGY STAR certified heat pumps qualify.
The outdoor unit must be at least 12,000 BTU/h nominal in cooling.
The grant never exceeds the purchase and installation cost, before taxes.
You apply no later than nine months after installation.
July 8, 2027
Wall, central or through the building.
| Type | Models |
|---|---|
| Wired | UTY-RNRUZ series, UTY-RSRYZ series, UTY-RHRYZ series |
| Wireless | UTY-LNHU series, UTY-LNVY series |
| IR receivers | UTY-TRHX, UTY-LBHXD |
| Central controllers | UTY-APGXZ, UTY-ALGXZ, UTY-DTGYZ, UTY-DCGYZ |
| BACnet, Modbus and Wi-Fi gateways | UTY-ABGXZ (BACnet software), UTY-VBGX (BACnet hardware), UTY-VLGX, UTY-VMGX (Modbus), UTY-TERX, UTY-TFSXJ series (WLAN) |
| Not for the J-7S | UTY-RVRU KAGAMI, UTY-DSGYZ AIRSTAGE Edge, UTY-LNVU, UTY-VTGX |
Fujitsu’s VRF accessory table. Integration with a building management system (BACnet, Modbus) is planned at quote time.
From 8 to 12 indoor units.
The J-II range comes in 3, 4 and 5 tons.
Fujitsu announces the J-IIS: 3 and 4 tons, up to 8 indoor units.
All Fujitsu VRF and mini-split lines take the AIRSTAGE name.
The J-7S becomes available, per ENERGY STAR.
Fujitsu officially introduces the J-7S: 2, 3 and 4 tons, up to 12 indoor units.
All three sizes are certified ENERGY STAR Cold Climate and Most Efficient.
Fujitsu lists a floor-mounted indoor unit (AGUA) for its VRF lineup.
What Fujitsu puts in the J-7S.
VRF heat pump: the whole system heats or cools. Choosing the mode room by room takes a heat recovery system.
Heating down to -26 °C, with no cold-weather lockout, according to Fujitsu.
The 2-ton model keeps up to 89% of its capacity at -18 °C.
Built-in heater in the outdoor unit’s base: defrost water doesn’t freeze.
Optional Wi-Fi with Fujitsu’s UTY-TFSXJ series adapter.
Leak detection sensor built into the ducted indoor units; alarm and automatic shut-off valve available as options.
Central controllers, BACnet gateways and a Modbus converter for building management.
The outdoor unit can sit under a window or on a balcony, below the railing height.
R-32 refrigerant: global warming potential of 675.
J-7S indoor units and accessories work only with J-7S outdoor units.
The three sizes, line by line.
| J-7S 2 tons | J-7S 3 tons | J-7S 4 tons | |
|---|---|---|---|
| Indoor unit | ASUA***KSA1 / AUUA***KSA1 / ARUL***KSA1 / ARUX***KSA1 | ASUA***KSA1 / AUUA***KSA1 / ARUL***KSA1 / ARUX***KSA1 | ASUA***KSA1 / AUUA***KSA1 / ARUL***KSA1 / ARUX***KSA1 |
| Outdoor unit | AOUK024SSAN7 | AOUK036SSAN7 | AOUK048SSAN7 |
| AHRI number | 216372779 | 216372781 | 216372783 |
| Heats down to | -26 °C | -26 °C | -26 °C |
| Rated heating | 28,000 BTU/h | 42,000 BTU/h | 54,000 BTU/h |
| Rated cooling | 24,000 BTU/h | 36,000 BTU/h | 48,000 BTU/h |
| SEER2 | 22.2 | 21.7 | 20.2 |
| EER2 | 15.7 | 13.6 | 11.4 |
| HSPF2 | 11.3 | 10.8 | 10.2 |
| Indoor sound (min / max) | – | – | – |
| Outdoor sound | – | – | – |
| Indoor, w×h×d | – | – | – |
| Outdoor, w×h×d | – | – | – |
| Weight in / out | – / – kg | – / – kg | – / – kg |
| Max line set / height | – / – m | – / – m | – / – m |
| Breaker | – | – | – |
| Refrigerant charge | – | – | – |
| ENERGY STAR | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate |
| Indicative LogisVert | $2,088 | $3,144 | $4,296 |
What Fujitsu’s sheets tell.
A single 4-ton J-7S outdoor unit feeds up to 12 indoor units.
Source: FujitsuThe outdoor unit can tuck under a window or below a balcony railing.
Source: FujitsuUp to 120 m of total piping, 50% more than before.
Source: FujitsuAll three sizes are ENERGY STAR Most Efficient and Cold Climate.
Source: ENERGY STARIn 2017 the J-IIS took 8 indoor units; the 4-ton J-7S takes 12.
Source: FujitsuThe J-7S uses 12% less refrigerant than the previous generation.
Source: FujitsuThe smallest indoor unit is 4,000 BTU/h, just right for a small office.
Source: FujitsuUp to 12 years on parts and compressor.
For VRF, Fujitsu has its own ladder: 5 years parts and 7 years compressor as standard, 10 and 10 years registered, 12 and 12 years with an Elite-tier contractor. AirGreen is Elite Plus.
Fujitsu limited warranty statement for J- and V-series VRF.
The condition for the 12-year tier on the J-IV, J-IVS, J-7 and J-7S. AirGreen is Elite Plus.
Fujitsu writes that Québec residents are not required to register the system. AirGreen registers it anyway.
Job sites with five or more outdoor systems must be commissioned, according to Fujitsu.
Fujitsu’s VRF, AirGreen’s job site.
A VRF is a design: the number of units, the connected capacity, the piping route and the controls. AirGreen does it with you, installs and registers the warranty.
What FUJITSU AIRSTAGE brings
- Up to 12 roomsOn a single outdoor unit.
- 120 m of pipingIn total, according to Fujitsu.
- Down to -26 °CNo low-temperature lockout.
- Up to 12 yearsParts and compressor, on Fujitsu’s conditions.
What AirGreen brings
- Elite Plus dealerThe highest level of the AIRSTAGE Elite program.
- Free home estimateWe measure and check the insulation and the location.
- Warranty registered for youWith Fujitsu, within 60 days.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: a whole floor, or a whole plex, on one outdoor unit.
Elite Plus: the highest level of the AIRSTAGE Elite program.
Fujitsu’s Japanese engineering, installed by an Elite Plus team across Montreal, Laval, Longueuil, the North Shore, the South Shore and Montérégie.
The highest level of the AIRSTAGE Elite program.
Our technicians take the manufacturer’s training on AIRSTAGE systems.
Vacuum, refrigerant settings, electrical hookup, set up for winter.
Manufacturer parts and Fujitsu technical support, wherever we install.
Free. We measure and check the insulation and the location.
The model, the size and the indicative LogisVert amount, in writing.
Vacuum, refrigerant, electrical, winter settings.
We register the unit with Fujitsu and help you with LogisVert.
What people ask us about VRF.
No question matches. Call us at 514 316-2973.
A variable refrigerant flow system: one outdoor unit feeds several indoor units through branched refrigerant piping. Each room has its own unit and its own control.
Up to 5 on the 2-ton J-7S, 9 on the 3-ton and 12 on the 4-ton.
Fujitsu rates it to heat down to -26 °C, with no cold-weather lockout. The 2-ton keeps up to 89% of its capacity at -18 °C, and a base heater keeps defrost water from freezing.
The J-7S is a VRF heat pump. Choosing the mode room by room takes a heat recovery system with branch boxes. We’ll advise you based on your building.
No. Fujitsu states that J-7S indoor units and accessories work only with J-7S outdoor units.
Wall-mounted, compact cassette, slim duct and multi-position air handler, from 4,000 to 60,000 BTU/h depending on the type.
Up to 120 m (393 ft) of total piping, according to Fujitsu. The other limits, such as the farthest unit and height differences, are checked in the technical manual for each project.
The outdoor unit is compact: Fujitsu says it can sit under a window or on a balcony, below the railing height. The J-7S is aimed at offices, shops and multi-unit buildings.
Wall controllers (UTY-RNRUZ, UTY-RSRYZ, UTY-RHRYZ), wireless remotes, central controllers, BACnet and Modbus gateways, and a Wi-Fi adapter.
Standard: 7 years on the compressor and 5 years on parts. With online registration: 10 years parts and compressor, for 4 outdoor units or fewer. Installed by an Elite-tier (or higher) contractor and registered: 12 years. Sites with 5 or more outdoor units must be commissioned.
All three sizes are ENERGY STAR Cold Climate certified. LogisVert is a residential program, though, built around one system per dwelling. We confirm your configuration’s eligibility before quoting it.
Yes. The ducted indoor units have a built-in leak detection sensor. Fujitsu also offers an optional alarm kit and an automatic shut-off valve kit.
Related collections.
For 2 to 5 rooms, FUJITSU Aquila multi-zone heat pumps are another option.
View the collectionControlsThermostats and controlsThe wall controllers that work with the J-7S.
View the collectionPartsParts and accessoriesBACnet and Modbus gateways, Wi-Fi adapter and other FUJITSU accessories.
View the collectionIndoor unitCeiling cassettesFUJITSU ceiling cassettes for single-zone systems.
View the collectionIndoor unitDucted unitsFUJITSU ducted units for single-zone systems.
View the collectionYour VRF, designed and installed by an Elite Plus team.
We come and look at the rooms, the outdoor unit location and the piping route, and give you a clear quote.
Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump: hang up.
Sources checked on October 8, 2026
27 sources · show
- Fujitsu AIRSTAGE, airstagehvac.com/j7sOutdoor/outdoor
- Fujitsu, press release J7S-PR
- Fujitsu, brochure FG8163C
- Fujitsu, brochure FG8163D
- Fujitsu AIRSTAGE, airstagehvac.com/products/vrf
- Fujitsu AIRSTAGE, airstagehvac.com/pr/indoor
- Fujitsu AIRSTAGE, airstagehvac.com/pr/accessories
- Fujitsu AIRSTAGE, airstagehvac.com/j7/outdoor
- Fujitsu AIRSTAGE, airstagehvac.com/vu7/outdoor
- Fujitsu, product or archive page VR2
- Fujitsu, press release JIIS-PR
- Fujitsu, press release REBRAND
- Fujitsu AIRSTAGE, document pdf-fcus-warranty-j-v-series-2026-01
- Fujitsu AIRSTAGE, airstagehvac.com/benefits/app-and-solutions
- Fujitsu AIRSTAGE, airstagehvac.com/controller/uty-rnru
- Fujitsu AIRSTAGE, airstagehvac.com/controller/uty-rhry
- Fujitsu, technical sheet fujitsu_aou36rlavs_article_4651940620724889_en_ii (distributor copy)
- ENERGY STAR, certified air-source heat pump list (dataset w7cv-9xjt)
- NEEP, cold-climate heat pump list
- Hydro-Québec, logisvert guide participation residentiel fr
- Government of Québec, Q 2,%20r.%2029
- Régie du bâtiment du Québec, subclass 15.10
- Régie du bâtiment du Québec, subclass 15.8
- Régie du bâtiment du Québec, subclass 17.1
- Trade press, buildings.com
- airgreen.ca product sheets, read October 8, 2026
- AirGreen, “Nos réalisations” projects blog
Amounts shown are estimates; only Hydro-Québec confirms the grant. Manufacturer data is quoted “according to Fujitsu”.
The J-7S systems, right below.
One product per size and indoor-unit count. Each product sheet gives the AHRI number and the rated capacity.