FUJITSU ducted units: several rooms, one hidden unit.
Seven R-32 medium-static ducted units, from 12,000 to 48,000 BTU/h, all 300 mm tall. The unit sits above the ceiling or in a bulkhead, measures your ducts’ pressure on its own and blows into several rooms. Built-in drain pump and leak sensor.
All you see are the grilles
The ducted unit hides in the ceiling, a bulkhead or a closet, and sends air to several rooms through short ducts.
Hidden, yet it heats several rooms.
Six facts from Fujitsu submittal sheets and Hydro-Québec’s LogisVert guide. Sources are at the bottom of the page.
One height for every R-32 size: 300 mm, from 12,000 to 48,000 BTU.
Up to 0.80 in WG (200 Pa) of static pressure to serve several rooms.
The unit detects your ducts’ static pressure on its own.
Built-in refrigerant leak sensor on the R-32 models.
Works with Airzone zoning.
Hydro-Québec excludes from LogisVert the unit and ducts installed outside the insulation, in a cold attic.
300 mm tall, at every size.
Pick a size and slide to the free space above your ceiling. The body is drawn to scale: the height stays put, only the width changes.
| Size | Unit | Width × height | Static pressure |
|---|---|---|---|
| 12,000 | ARUH12KUAS | 700 × 300 mm | 30 to 200 Pa · 0.12 to 0.80 in WG |
| 18,000 | ARUH18KUAS | 1,000 × 300 mm | 30 to 200 Pa · 0.12 to 0.80 in WG |
| 24,000 | ARUH24KUAS | 1,000 × 300 mm | 30 to 200 Pa · 0.12 to 0.80 in WG |
| 30,000 | ARUH30KUAS | 1,000 × 300 mm | 30 to 200 Pa · 0.12 to 0.80 in WG |
| 36,000 | ARUH36KUAS | 1,400 × 300 mm | 30 to 200 Pa · 0.12 to 0.80 in WG |
| 42,000 | ARUH42KUAS | 1,400 × 300 mm | 30 to 180 Pa · 0.12 to 0.72 in WG |
| 48,000 | ARUH48KUAS | 1,400 × 300 mm | 30 to 180 Pa · 0.12 to 0.72 in WG |
| Slim 9 000 · 12 000 | ADUH09/12LUAS1 | 700 × 198 mm | 0 to 90 Pa · 0 to 0.36 in WG |
| Slim LUAS1 18 000 | ADUH18LUAS1 | 900 × 198 mm | 0 to 90 Pa · 0 to 0.36 in WG |
Body height only, according to Fujitsu. Ducts, the drain and some clearance also need room: we measure on site.
Seven R-32 ducted units, then the R-410A generations.
Tap a model: photo, sheet, efficiency and LogisVert amount. The LUAS1 and RLF slim units are R-410A multi-zone heads.
Enough push for several rooms.
Static pressure is the resistance of the ducts, grilles and filter. The more a ducted unit can overcome, the more rooms it can serve.
The pressure each ducted unit can push against
External static pressure range published by Fujitsu. The higher it goes, the longer and more numerous the ducts can be. The network is sized on site.
The R-32 ducted units detect the ducts’ static pressure on their own and set their fan, according to Fujitsu.
The return air connects at the back or the bottom of the body, depending on the space available.
Fujitsu states compatibility with Airzone zoning: motorized dampers set each room.
A ducted unit is not a furnace: it serves a few nearby rooms through short ducts. For the whole house, see the Centauri air handler.
Same outdoor unit, different efficiency.
On the same Centauri outdoor unit, the ducted unit has a lower SEER2 than the cassette or the floor-ceiling unit. The LogisVert amount stays the same.
AOUH12KUAS1
| Compact cassette | SEER2 23.7 |
| Ducted | SEER2 19.1 |
| LogisVert, whatever the indoor unit | $1,284 |
ENERGY STAR list. The ducted unit has the lowest SEER2 of the four: the air goes through ducts. LogisVert is computed from the capacity rated at -8 °C, the same here for every indoor unit: 10,700 BTU/h.
AOUH18KUAS1
| Circular cassette | SEER2 26.3 |
| Floor-ceiling | SEER2 23.4 |
| Compact cassette | SEER2 21.9 |
| Ducted | SEER2 18.6 |
| LogisVert, whatever the indoor unit | $1,728 |
ENERGY STAR list. The ducted unit has the lowest SEER2 of the four: the air goes through ducts. LogisVert is computed from the capacity rated at -8 °C, the same here for every indoor unit: 14,400 BTU/h.
AOUH24KUAS1
| Circular cassette | SEER2 23.2 |
| Floor-ceiling | SEER2 21.7 |
| Ducted | SEER2 18.5 |
| LogisVert, whatever the indoor unit | $2,136 |
ENERGY STAR list. The ducted unit has the lowest SEER2 of the four: the air goes through ducts. LogisVert is computed from the capacity rated at -8 °C, the same here for every indoor unit: 17,800 BTU/h.
AOUH30KUAS1
| Circular cassette | SEER2 22.4 |
| Floor-ceiling | SEER2 20.8 |
| Ducted | SEER2 18.5 |
| LogisVert, whatever the indoor unit | $2,544 |
ENERGY STAR list. The ducted unit has the lowest SEER2 of the four: the air goes through ducts. LogisVert is computed from the capacity rated at -8 °C, the same here for every indoor unit: 21,200 BTU/h.
AOUH36KUAS1
| Circular cassette | SEER2 21.3 |
| Floor-ceiling | SEER2 21.3 |
| Ducted | SEER2 18 |
| LogisVert, whatever the indoor unit | $3,048 |
ENERGY STAR list. The ducted unit has the lowest SEER2 of the four: the air goes through ducts. LogisVert is computed from the capacity rated at -8 °C, the same here for every indoor unit: 25,400 BTU/h.
AOUH42KUAS1
| Circular cassette | SEER2 19 |
| Ducted | SEER2 17.3 |
| LogisVert, whatever the indoor unit | $3,840 |
ENERGY STAR list. The ducted unit has the lowest SEER2 of the four: the air goes through ducts. LogisVert is computed from the capacity rated at -8 °C, the same here for every indoor unit: 32,000 BTU/h.
AOUH48KUAS1
| Circular cassette | SEER2 18.2 |
| Ducted | SEER2 16.4 |
| LogisVert, whatever the indoor unit | $4,320 |
ENERGY STAR list. The ducted unit has the lowest SEER2 of the four: the air goes through ducts. LogisVert is computed from the capacity rated at -8 °C, the same here for every indoor unit: 36,000 BTU/h.
Down to -21 °C with the Centauri units.
Bars: maximum capacity published by Fujitsu and capacity at -15 °C (ENERGY STAR). Red tick: the rated values, including the -8 °C one LogisVert uses.
| Size | 8.3 °C | -8.3 °C | -15 °C |
|---|---|---|---|
| Centauri R-32 ducted 12,000 | 19,400 BTU/h | 17,300 BTU/h | 15,500 BTU/h |
| Centauri R-32 ducted 18,000 | 25,600 BTU/h | 19,300 BTU/h | 17,100 BTU/h |
| Centauri R-32 ducted 24,000 | 32,000 BTU/h | 26,000 BTU/h | 23,600 BTU/h |
| Centauri R-32 ducted 30,000 | 38,000 BTU/h | 30,900 BTU/h | 28,000 BTU/h |
| Centauri R-32 ducted 36,000 | 43,000 BTU/h | 34,500 BTU/h | 31,000 BTU/h |
| Centauri R-32 ducted 42,000 | 51,000 BTU/h | 41,000 BTU/h | 37,000 BTU/h |
| Centauri R-32 ducted 48,000 | 56,000 BTU/h | 43,200 BTU/h | 38,500 BTU/h |
At -8 °C the rated value is a part-load test. Values with the ducted unit, per Fujitsu and ENERGY STAR.
The XLTH outdoor unit, 30,000 to 48,000.
Fujitsu also pairs these ducted units with an XLTH outdoor unit that heats down to -26 °C. Compare, size by size.
ARUH30KUAS vs ARUH30KUAS · XLTH
| ARUH30KUAS | ARUH30KUAS · XLTH | |
|---|---|---|
| At +8 °C (rated) | 32,000 BTU/h | 32,000 BTU/h |
| At -8 °C (rated) | 21,200 BTU/h | 21,000 BTU/h |
| At -15 °C | 28,000 BTU/h | 33,000 BTU/h |
| Heats down to | -21 °C | -26 °C |
| SEER2 | 18.5 | 18 |
| HSPF2 | 10 | 10 |
| Indicative LogisVert | $2,544 | $2,520 |
Same ducted unit, different outdoor unit. The XLTH gives more heat at -15 °C and heats down to -26 °C, with no low-temperature lockout according to Fujitsu. Its LogisVert amount stays close or a little lower: it is computed from the value rated at -8 °C.
ARUH36KUAS vs ARUH36KUAS · XLTH
| ARUH36KUAS | ARUH36KUAS · XLTH | |
|---|---|---|
| At +8 °C (rated) | 38,000 BTU/h | 38,000 BTU/h |
| At -8 °C (rated) | 25,400 BTU/h | 25,200 BTU/h |
| At -15 °C | 31,000 BTU/h | 40,000 BTU/h |
| Heats down to | -21 °C | -26 °C |
| SEER2 | 18 | 18 |
| HSPF2 | 9.8 | 10 |
| Indicative LogisVert | $3,048 | $3,024 |
Same ducted unit, different outdoor unit. The XLTH gives more heat at -15 °C and heats down to -26 °C, with no low-temperature lockout according to Fujitsu. Its LogisVert amount stays close or a little lower: it is computed from the value rated at -8 °C.
ARUH42KUAS vs ARUH42KUAS · XLTH
| ARUH42KUAS | ARUH42KUAS · XLTH | |
|---|---|---|
| At +8 °C (rated) | 47,000 BTU/h | 47,000 BTU/h |
| At -8 °C (rated) | 32,000 BTU/h | 31,600 BTU/h |
| At -15 °C | 37,000 BTU/h | 48,000 BTU/h |
| Heats down to | -21 °C | -26 °C |
| SEER2 | 17.3 | 19.5 |
| HSPF2 | 10.2 | 10.2 |
| Indicative LogisVert | $3,840 | $3,792 |
Same ducted unit, different outdoor unit. The XLTH gives more heat at -15 °C and heats down to -26 °C, with no low-temperature lockout according to Fujitsu. Its LogisVert amount stays close or a little lower: it is computed from the value rated at -8 °C.
ARUH48KUAS vs ARUH48KUAS · XLTH
| ARUH48KUAS | ARUH48KUAS · XLTH | |
|---|---|---|
| At +8 °C (rated) | 51,000 BTU/h | 51,000 BTU/h |
| At -8 °C (rated) | 36,000 BTU/h | 34,000 BTU/h |
| At -15 °C | 38,500 BTU/h | 51,000 BTU/h |
| Heats down to | -21 °C | -26 °C |
| SEER2 | 16.4 | 19 |
| HSPF2 | 10 | 10 |
| Indicative LogisVert | $4,320 | $4,080 |
Same ducted unit, different outdoor unit. The XLTH gives more heat at -15 °C and heats down to -26 °C, with no low-temperature lockout according to Fujitsu. Its LogisVert amount stays close or a little lower: it is computed from the value rated at -8 °C.
ENERGY STAR and Fujitsu data. These XLTH pairings are not in our online shop: ask about them at the estimate.
Where the unit goes matters.
All seven R-32 ducted units are ENERGY STAR cold climate: $1,284 to $4,320. But a unit or ducts outside the insulation, in a cold attic, are excluded.
- Is the indoor unit inside the heated, insulated part of the house? Yes
- Do the ducts stay inside the insulation, not in a cold attic? Yes
- Is a complete system being installed, outdoor unit included? Yes
- Is the chosen model an R-32 ducted unit from our catalogue? Yes
| Model | Indicative amount | Calculation |
|---|---|---|
| Centauri R-32 ducted 12,000 | $1,284 | 10,700 BTU/h ÷ 1,000 × $120 = $1,284 |
| Centauri R-32 ducted 18,000 | $1,728 | 14,400 BTU/h ÷ 1,000 × $120 = $1,728 |
| Centauri R-32 ducted 24,000 | $2,136 | 17,800 BTU/h ÷ 1,000 × $120 = $2,136 |
| Centauri R-32 ducted 30,000 | $2,544 | 21,200 BTU/h ÷ 1,000 × $120 = $2,544 |
| Centauri R-32 ducted 36,000 | $3,048 | 25,400 BTU/h ÷ 1,000 × $120 = $3,048 |
| Centauri R-32 ducted 42,000 | $3,840 | 32,000 BTU/h ÷ 1,000 × $120 = $3,840 |
| Centauri R-32 ducted 48,000 | $4,320 | 36,000 BTU/h ÷ 1,000 × $120 = $4,320 |
| RGLX ducted 12,000 | $0 | – |
| RGLX ducted 18,000 | $635 | – |
| RGLX ducted 24,000 | $865 | – |
| RGLX ducted 42,000 | $0 | – |
Since November 26, 2025, only ENERGY STAR certified heat pumps qualify.
The outdoor unit must be at least 12,000 BTU/h nominal in cooling.
The grant never exceeds the purchase and installation cost, before taxes.
You apply no later than nine months after installation.
July 8, 2027
Three long-life filters, by size.
12,000 BTU/h
| Fujitsu long-life filter (option) | UTD-LFNC |
| For the ducted units | ARUH12KUAS |
The filter supplied in the box is not described in Fujitsu’s sheets. The long-life filter is an option, chosen at quote time.
18,000 to 30,000
| Fujitsu long-life filter (option) | UTD-LFNB |
| For the ducted units | ARUH18KUAS, ARUH24KUAS, ARUH30KUAS |
The filter supplied in the box is not described in Fujitsu’s sheets. The long-life filter is an option, chosen at quote time.
36,000 to 48,000
| Fujitsu long-life filter (option) | UTD-LFNA |
| For the ducted units | ARUH36KUAS, ARUH42KUAS, ARUH48KUAS |
The filter supplied in the box is not described in Fujitsu’s sheets. The long-life filter is an option, chosen at quote time.
A ducted unit, on the scale of everyday sounds.
Levels published by Fujitsu for the ducted unit and the outdoor unit. The unit is outside the room: you mostly hear the air at the grilles.
| Model | Indoor, quiet speed | Indoor, high speed | Outdoor unit |
|---|---|---|---|
| Centauri R-32 ducted 12,000 | 24 dB(A) | 35 dB(A) | – |
| Centauri R-32 ducted 18,000 | 24 dB(A) | 34 dB(A) | 55 dB(A) |
| Centauri R-32 ducted 24,000 | 24 dB(A) | 36 dB(A) | 54 dB(A) |
| Centauri R-32 ducted 30,000 | 30 dB(A) | 39 dB(A) | 57 dB(A) |
| Centauri R-32 ducted 36,000 | 26 dB(A) | 37 dB(A) | 59 dB(A) |
| Centauri R-32 ducted 42,000 | 29 dB(A) | 40 dB(A) | 57 dB(A) |
| Centauri R-32 ducted 48,000 | 29 dB(A) | 40 dB(A) | 59 dB(A) |
Levels published by Fujitsu, measured in a lab; at home, the room, the furniture and the distance change what you hear. Scale: Government of Québec reference points.
Up to 75 m depending on size.
Drag the sliders: length and height between the two units, per Fujitsu’s limits.
| Model | Max length | Max height | Pre-charge | Minimum |
|---|---|---|---|---|
| Centauri R-32 ducted 12,000 | 30 m | 15 m | 20 m | 5 m |
| Centauri R-32 ducted 18,000 | 30 m | 15 m | – | 5 m |
| Centauri R-32 ducted 24,000 | 50 m | – | – | – |
| Centauri R-32 ducted 30,000 | 50 m | 30 m | 20 m | 5 m |
| Centauri R-32 ducted 36,000 | 50 m | 30 m | 20 m | 5 m |
| Centauri R-32 ducted 42,000 | 75 m | – | – | 5 m |
| Centauri R-32 ducted 48,000 | 75 m | 30 m | 30 m | 5 m |
A ducted unit can also be a multi-zone head.
The ARUH12, 18 and 24KUAS are on Fujitsu’s indoor-unit list for the R-32 multi-zones: a ducted unit can serve one floor, wall heads the rest.
These sizes pair only with their own outdoor unit.
The LUAS1 and RLF slim units have no outdoor unit of their own, nor a LogisVert amount of their own: they are R-410A multi-zone heads.
Fujitsu accepts the LUAS1 heads on this unit: 27,000 to 39,000 BTU/h connected, 70 m of line set in total and 25 m per room.
The previous generation, line by line.
Most RGLX are not on the ENERGY STAR list: $0 in LogisVert. Only the 18,000 and 24,000 are, without the cold-climate mention.
| Size | Indoor | Outdoor | ENERGY STAR | LogisVert | At Fujitsu |
|---|---|---|---|---|---|
| 12,000 | ARU12RGLX | AOU12RLFC | No | $0 | Retired by Fujitsu |
| 18,000 | ARU18RGLX | AOU18RGLX | Yes, without the cold-climate mention | $635 | Retired by Fujitsu |
| 24,000 | ARU24RGLX | AOU24RGLX | Yes, without the cold-climate mention | $865 | Retired by Fujitsu |
| 30,000 | ARU30RGLX | – | No | $0 | Retired by Fujitsu |
| 36,000 | ARU36RGLX | – | No | $0 | Retired by Fujitsu |
| 42,000 | ARU42RGLX | AOU42RGLX | No | $0 | Offered as RGLXD |
| 48,000 | ARU48RGLX | – | No | $0 | Offered as RGLXD |
ENERGY STAR list and Fujitsu pages. The RGLX are the previous R-410A generation; availability and pairing are confirmed at quote time.
A wall controller to choose.
| Model | Role |
|---|---|
| UTY-LBTUM | IR receiver kit with wireless remote |
| UTY-RVRU | KAGAMI touch-panel wired controller |
| UTY-RNRUZ5 | touch-panel wired remote controller |
| UTY-RHRY / UTY-RSRY | simple wired remotes |
| UTY-TTRXZ1 / TTRXZ1-KIT | 24 V thermostat interface (cannot be used with other control types) |
| UTY-XSZXZ1 | remote temperature sensor |
| FJ-IR-WIFI-1NA, BM101WA/BM102WA | Intesis or Cielo IR Wi-Fi (needs the UTY-LBTUM) |
| UTY-VMSX / FJ-AC-485-1 / UTY-DSGYZ2 | Modbus or BACnet gateway, AIRSTAGE Edge controller |
A ducted unit has no display: it needs a controller. Fujitsu lists them all as options; one is chosen at quote time. The exact Wi-Fi adapter is also confirmed at quote time.
What Fujitsu puts in its R-32 ducted units.
Unit hidden in a ceiling, bulkhead or closet: you only see the grilles.
300 mm tall at every size, from 12,000 to 48,000 BTU.
The unit detects your ducts’ static pressure by itself.
Up to 0.80 in WG (200 Pa) of external static pressure to feed several ducts.
Built-in refrigerant leak detection sensor.
Built-in drain pump.
Return air from the side or the bottom.
Optional Fujitsu long-life filter.
Compatible with Airzone third-party zoning.
Optional Wi-Fi with the Fujitsu adapter.
Hidden unit: a wall controller or the UTY-LBTUM infrared kit is needed.
BACnet and Modbus compatible with a gateway.
Inputs and outputs for a fire alarm, door switch, humidifier or back-up heat.
R-32 refrigerant: global warming potential of 675.
Also available as a head on an R-32 multi-zone system.
Up to 0.72 in WG (180 Pa) of external static pressure.
The R-32 ducted units, line by line.
| Centauri R-32 ducted 12,000 | Centauri R-32 ducted 18,000 | Centauri R-32 ducted 24,000 | Centauri R-32 ducted 30,000 | Centauri R-32 ducted 36,000 | Centauri R-32 ducted 42,000 | Centauri R-32 ducted 48,000 | |
|---|---|---|---|---|---|---|---|
| Indoor unit | ARUH12KUAS | ARUH18KUAS | ARUH24KUAS | ARUH30KUAS | ARUH36KUAS | ARUH42KUAS | ARUH48KUAS |
| Outdoor unit | AOUH12KUAS1 | AOUH18KUAS1 | AOUH24KUAS1 | AOUH30KUAS1 | AOUH36KUAS1 | AOUH42KUAS1 | AOUH48KUAS1 |
| AHRI number | 215434556 | 215434557 | 215434558 | 215434559 | 215434560 | 215812202 | 215812203 |
| Heats down to | -21 °C | -21 °C | -21 °C | -21 °C | -21 °C | -21 °C | -21 °C |
| Rated heating | 16,000 BTU/h | 21,600 BTU/h | 27,000 BTU/h | 32,000 BTU/h | 38,000 BTU/h | 47,000 BTU/h | 51,000 BTU/h |
| Rated cooling | 12,000 BTU/h | 18,000 BTU/h | 24,000 BTU/h | 30,000 BTU/h | 36,000 BTU/h | 42,000 BTU/h | 46,000 BTU/h |
| SEER2 | 19.1 | 18.6 | 18.5 | 18.5 | 18 | 17.3 | 16.4 |
| EER2 | 12.7 | 11.7 | 11.7 | 11 | 10.4 | 10.3 | 9.8 |
| HSPF2 | 10.5 | 10.3 | 10.2 | 10 | 9.8 | 10.2 | 10 |
| Indoor sound (min / max) | 24 / 35 dB(A) | 24 / 34 dB(A) | 24 / 36 dB(A) | 30 / 39 dB(A) | 26 / 37 dB(A) | 29 / 40 dB(A) | 29 / 40 dB(A) |
| Outdoor sound | – | 55 dB(A) | 54 dB(A) | 57 dB(A) | 59 dB(A) | 57 dB(A) | 59 dB(A) |
| Indoor, w×h×d | 700×300×700 mm | 1,000×300×700 mm | 1,000×300×700 mm | 1,000×300×700 mm | 1,400×300×700 mm | 1,400×300×700 mm | 1,400×300×700 mm |
| Outdoor, w×h×d | 799×632×290 mm | 799×632×290 mm | 940×788×320 mm | 940×998×320 mm | 940×998×320 mm | 940×998×320 mm | 940×998×320 mm |
| Weight in / out | 30 / 38 kg | 41 / 38 kg | 42 / 52 kg | – / 62 kg | 55 / 62 kg | 55 / 71 kg | 55 / 71 kg |
| Max line set / height | 30 / 15 m | 30 / 15 m | 50 / – m | 50 / 30 m | 50 / 30 m | 75 / – m | 75 / 30 m |
| Breaker | – | – | 20 A | 25 A | 25 A | – | – |
| Refrigerant charge | 1.0 kg | 1.2 kg | 1.5 kg | 2 kg | 2 kg | 2.7 kg | 2.7 kg |
| ENERGY STAR | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate |
| Indicative LogisVert | $1,284 | $1,728 | $2,136 | $2,544 | $3,048 | $3,840 | $4,320 |
What Fujitsu’s sheets tell.
From 12,000 to 48,000 BTU, the R-32 ducted unit keeps the same 300 mm height. Only its width changes.
Source: FujitsuThe unit detects the static pressure of your ducts by itself.
Source: FujitsuENERGY STAR sets a separate cold-climate bar for ducted systems: 8.1 HSPF2, versus 8.5 for ductless.
Source: ENERGY STARThe R-32 models include a refrigerant leak sensor.
Source: FujitsuThe previous RGLX series lifted condensate 33.5 in straight up.
Source: FujitsuAt Quiet speed, the 12,000 to 24,000 BTU models go down to 24 dB(A) in a lab.
Source: FujitsuThe 12,000 BTU model is rated at 16,000 BTU/h of heat at 8 °C.
Source: Fujitsu, ENERGY STARUp to 12 years on parts and compressor.
The longest tier needs online registration within 60 days and a Fujitsu Elite contractor. At AirGreen, both are done for you.
In Québec, the basic warranty needs no registration; the 10- and 12-year tiers do. Source: Fujitsu limited warranty statement (R-32).
We register your unit with Fujitsu, free, on time.
The condition for the 12-year tier. AirGreen is Elite Plus.
The warranty requires a licensed contractor. RBQ 5645-9605-01.
Fujitsu’s text excludes systems bought from an online retailer.
Fujitsu’s ducted unit, AirGreen’s ductwork.
A ducted unit is only as good as its ducts. AirGreen checks the space, runs short ducts inside the insulation, connects the drain and registers the warranty.
What FUJITSU AIRSTAGE brings
- 300 mm everywhereOne height for all seven R-32 sizes.
- Pressure measuredThe unit detects the ducts’ static pressure.
- Down to -21 °CWith the Centauri outdoor units.
- Up to 12 yearsParts and compressor, on Fujitsu’s conditions.
What AirGreen brings
- Elite Plus dealerThe highest level of the AIRSTAGE Elite program.
- Free home estimateWe measure and check the insulation and the location.
- Warranty registered for youWith Fujitsu, within 60 days.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: heated rooms with nothing on the wall.
Recent installations, in photos.
Each article on our blog tells a real installation: the place, the constraint and the solution.
Elite Plus: the highest level of the AIRSTAGE Elite program.
Fujitsu’s Japanese engineering, installed by an Elite Plus team across Montreal, Laval, Longueuil, the North Shore, the South Shore and Montérégie.
The highest level of the AIRSTAGE Elite program.
Our technicians take the manufacturer’s training on AIRSTAGE systems.
Vacuum, refrigerant settings, electrical hookup, set up for winter.
Manufacturer parts and Fujitsu technical support, wherever we install.
Free. We measure and check the insulation and the location.
The model, the size and the indicative LogisVert amount, in writing.
Vacuum, refrigerant, electrical, winter settings.
We register the unit with Fujitsu and help you with LogisVert.
What people ask us about ducted units.
No question matches. Call us at 514 316-2973.
The R-32 ducted unit is 300 mm tall at every size, from 12,000 to 48,000 BTU. Installation clearance comes on top, and we measure it on site.
Yes, through ducts. Fujitsu gives up to 0.80 in WG (200 Pa) of external static pressure from 12,000 to 36,000 BTU, and 0.72 in WG (180 Pa) at 42,000 and 48,000 BTU.
The R-32 models have a built-in drain pump. We then connect its outlet to a drain.
Fujitsu offers optional long-life filters: UTD-LFNC (12,000 BTU), UTD-LFNB (18,000 to 30,000 BTU) and UTD-LFNA (36,000 to 48,000 BTU).
Down to -21 °C with the standard outdoor unit. Fujitsu also offers an XLTH outdoor unit, from 30,000 to 48,000 BTU, that heats down to -26 °C.
The unit is hidden outside the room, so you mostly hear the air at the grilles. Fujitsu measures 24 dB(A) at Quiet speed on the 12,000 to 24,000 BTU models.
Yes for our seven R-32 ducted units installed inside the home’s insulated envelope: ENERGY STAR cold climate, 120 $ per 1,000 BTU/h at -8 °C, from 1,284 $ to 4,320 $. A unit or ducts installed outside the insulation, in a cold attic, are excluded by Hydro-Québec.
It is technically possible, but Hydro-Québec excludes from LogisVert indoor units and their air network installed outside the insulation. We factor this in from the quote.
The unit is hidden, so it needs a wall controller (for example KAGAMI UTY-RVRU) or the UTY-LBTUM receiver and remote kit. Wi-Fi is optional.
Yes for the ARUH12, 18 and 24KUAS, which Fujitsu lists as R-32 multi-zone indoor units.
Fujitsu states compatibility with Airzone third-party zoning.
The R-32 models have a built-in refrigerant leak detection sensor.
Related collections.
For the whole house through existing ducts, the Centauri R-32 air handler.
View the collectionCentralCentral heat pumpsAll FUJITSU central heat pumps and their electric back-up.
View the collectionIndoor unitCeiling cassettesIn a drop ceiling, a cassette only needs one tile opening.
View the collectionMulti-zoneMulti-zone heat pumpsThe 12,000 to 24,000 BTU ducted units can be heads of a multi-zone system.
View the collectionControlsThermostats and controlsThe wall controllers a hidden unit needs.
View the collectionYour ducted unit, installed by an Elite Plus team.
We come and look at the ceiling space and the duct route, choose the size and the controller, and give you a clear quote with the indicative LogisVert amount.
Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump: hang up.
Sources checked on October 8, 2026
32 sources · show
- Fujitsu AIRSTAGE, airstagehvac.com/r32/kuas1r
- Fujitsu AIRSTAGE, airstagehvac.com/products/split
- Fujitsu AIRSTAGE, airstagehvac.com/multi/r32-indoor
- Fujitsu AIRSTAGE, airstagehvac.com/r32-2-3-4rooms/kwas
- Fujitsu, submittal sheet 12KUAS1R
- Fujitsu, submittal sheet 18KUAS1R
- Fujitsu, submittal sheet 24KUAS1R
- Fujitsu, submittal sheet 30KUAS1R
- Fujitsu, submittal sheet 36KUAS1R
- Fujitsu, submittal sheet 42KUAS1R
- Fujitsu, submittal sheet 48KUAS1R
- Fujitsu, submittal sheet 24KUAS1U
- Fujitsu, submittal sheet 36KUAS1U
- Fujitsu, submittal sheet 30KUAS1B
- Fujitsu, submittal sheet 48KUAS1U
- Fujitsu, product or archive page LUAS1U
- Fujitsu, press release PR-RGLX
- Fujitsu, technical sheet Fujitsu-12RGLXD- (distributor copy)
- Fujitsu, technical sheet fujitsu_aru42rglx_article_2277393384679171_en_subs (distributor copy)
- Fujitsu, technical sheet 1572 (distributor copy)
- Fujitsu, technical sheet ARU12RLF-SUB (distributor copy)
- Fujitsu, technical sheet IndoorUnitSpecs (distributor copy)
- Fujitsu, technical sheet AOU36RLXFZ-TECH (distributor copy)
- Fujitsu, product or archive page AOU36RLXFZ1
- Fujitsu AIRSTAGE, document pdf-fcus-h-series-warranty-r32-202606
- ENERGY STAR, certified air-source heat pump list (dataset w7cv-9xjt)
- ENERGY STAR, program criteria
- NEEP, cold-climate heat pump list
- Hydro-Québec, LogisVert residential participation guide, version 1.10
- Hydro-Québec, LogisVert partner notice (ENERGY STAR required)
- Government of Québec, mesure du bruit
- airgreen.ca product sheets, read October 8, 2026
Amounts shown are estimates; only Hydro-Québec confirms the grant. Manufacturer data is quoted “according to Fujitsu”.