FUJITSU central heat pumps: the whole house through the ducts, down to -26 °C.
Two R-32 series share the same AMUH indoor unit: the Centauri heats down to -21 °C in six sizes, the Centauri XLTH down to -26 °C in three sizes. LogisVert pays $1,272 to $4,464 depending on size.
Names from the sky
Altair, Orion, Aquila, Centauri: names of stars and constellations. Centauri is the Latin genitive of Centaurus, the Centaur. Fujitsu does not explain the choice.
One machine, the whole house.
Six facts from Fujitsu documents, the ENERGY STAR list, the LogisVert guide and Hydro-Québec’s rates. Sources are at the bottom of the page.
The same AMUH indoor unit serves both series, Centauri (down to -21 °C) and Centauri XLTH (down to -26 °C).
Fujitsu offers 2 to 16 kW electric heater kits that fit inside the indoor unit, on a dedicated circuit.
For LogisVert, the indoor unit and the ducts must stay inside the home’s insulated envelope, not in the attic.
At -15 °C, the 48,000 Centauri XLTH gives 51,000 BTU/h, against 41,000 for the standard Centauri of the same size.
A heat pump with electric back-up is not a dual-energy system under Rate DT, which requires a fuel.
ENERGY STAR files these systems as "Mini or Multi Split", while Hydro-Québec calls them central split heat pumps.
From the outdoor unit to every room.
A central heat pump replaces the furnace or joins the existing duct system. Here is the air’s path.
It draws heat from the outside air in winter and rejects the house’s heat in summer.
Two copper pipes connect the outdoor unit to the indoor unit.
Its coil heats or cools the air; its fan pushes it into the ducts. The electric back-up, if any, sits here.
Warm or cool air reaches each room through the supply registers.
Air comes back to the unit through the return, past the filter.
A question of cold.
Slide to the coldest temperature the heat pump must cover alone: the Centauri goes to -21 °C, the XLTH to -26 °C.
| The coldest temperature you aim for | |
|---|---|
| Centauri | down to -21 °C |
| Centauri XLTH | down to -26 °C |
Heating ranges published by Fujitsu. Below its range, a heat pump has no published capacity: the back-up takes over.
| Series | Heats down to | Sizes (BTU/h) | ENERGY STAR | LogisVert |
|---|---|---|---|---|
| Centauri AOUH..KUAS1 + AMUH | -21 °C | 12,000 to 48,000 (6 sizes) | cold climate, all six | $1,272 – $4,464 |
| Centauri XLTH AOUH..KUAH1 + AMUH | -26 °C | 30,000, 36,000, 48,000 | cold climate, Most Efficient | $2,520 – $4,080 |
| Previous generation R-410A | – | 24,000 to 48,000 | 2 of 7 | $0 – $3,528 |
Ranges published by Fujitsu; indicative LogisVert amounts per the ENERGY STAR list ($120 per 1,000 BTU/h at -8 °C for cold climate).
From 1 to 4 tons.
Tap a system: photo, sheet, efficiency and LogisVert amount. The same AMUH indoor unit serves both series.
| Model | Heats down to | Max at -15 °C | SEER2 | HSPF2 | LogisVert | AHRI |
|---|---|---|---|---|---|---|
| Centauri 12,000 BTU/h | -21 °C | 16,100 BTU/h | 19.9 | 10.3 | $1,272 | 217290592 |
| Centauri 18,000 BTU/h | -21 °C | 17,300 BTU/h | 19.2 | 10.5 | $1,932 | 217290593 |
| Centauri 24,000 BTU/h | -21 °C | 24,600 BTU/h | 17.7 | 10.1 | $2,184 | 217290594 |
| Centauri 30,000 BTU/h | -21 °C | 29,400 BTU/h | 19 | 10 | $2,664 | 217290595 |
| Centauri 36,000 BTU/h | -21 °C | 32,000 BTU/h | 17.6 | 9.8 | $3,288 | 217290596 |
| Centauri 48,000 BTU/h | -21 °C | 41,000 BTU/h | 17 | 9.6 | $4,464 | 217290597 |
| Centauri XLTH 30,000 BTU/h | -26 °C | 34,000 BTU/h | 18.8 | 10 | $2,520 | 217895716 |
| Centauri XLTH 36,000 BTU/h | -26 °C | 41,000 BTU/h | 18.3 | 10.2 | $3,024 | 217895717 |
| Centauri XLTH 48,000 BTU/h | -26 °C | 51,000 BTU/h | 19 | 10.2 | $4,080 | 217895718 |
At -15 °C, the XLTH 48,000 gives 10,000 BTU/h more.
Bars: capacity at -15 °C (ENERGY STAR) and maximum capacity at the coldest published point (NEEP). Red tick: the rated values.
| Size | -15 °C | -20.6 °C | -26.1 °C |
|---|---|---|---|
| Centauri 12,000 | 16,100 BTU/h | 14,520 BTU/h | – |
| Centauri 18,000 | 17,300 BTU/h | 14,570 BTU/h | – |
| Centauri 24,000 | 24,600 BTU/h | 21,860 BTU/h | – |
| Centauri 30,000 | 29,400 BTU/h | 25,190 BTU/h | – |
| Centauri 36,000 | 32,000 BTU/h | 27,850 BTU/h | – |
| Centauri 48,000 | 41,000 BTU/h | 37,960 BTU/h | – |
| Centauri XLTH 30,000 | 34,000 BTU/h | – | 26,000 BTU/h |
| Centauri XLTH 36,000 | 41,000 BTU/h | – | 32,000 BTU/h |
| Centauri XLTH 48,000 | 51,000 BTU/h | – | 51,000 BTU/h |
At -8 °C the rated value is a part-load test: it can be lower than at -15 °C.
From 2 to 16 kW, inside the AMUH unit.
Pick a size: the Fujitsu kits that fit it, each on a dedicated circuit.
| Indoor unit | Fujitsu kits |
|---|---|
| 12,000 BTU/h · AMUH12KUAS | UTZ-EU02MSA · 2 kW — 6,824 BTU/h · 1 stage · breaker field-supplied UTZ-EU04MSB2 · 4 kW — 13,648 BTU/h · 2 stages · breaker field-supplied |
| 18,000 BTU/h · AMUH18KUAS | UTZ-EU03MSA · 3 kW — 10,236 BTU/h · 1 stage · breaker included UTZ-EU06MSB2 · 6 kW — 20,472 BTU/h · 2 stages · breaker field-supplied |
| 24,000 BTU/h · AMUH24KUAS | UTZ-EU02MSA · 2 kW — 6,824 BTU/h · 1 stage · breaker field-supplied UTZ-EU04MSA · 4 kW — 13,648 BTU/h · 1 stage · breaker included UTZ-EU08MSB2 · 8 kW — 27,296 BTU/h · 2 stages · breaker field-supplied |
| 30,000 BTU/h · AMUH30KUAS | UTZ-EU03MMA · 3 kW — 10,236 BTU/h · 1 stage · breaker included UTZ-EU05MMA · 5 kW — 17,060 BTU/h · 1 stage · breaker included UTZ-EU10MMB2 · 10 kW — 34,120 BTU/h · 2 stages · breaker included |
| 36,000 BTU/h · AMUH36KUAS | UTZ-EU03MMA · 3 kW — 10,236 BTU/h · 1 stage · breaker included UTZ-EU06MMA · 6 kW — 20,472 BTU/h · 1 stage · breaker included UTZ-EU12MMB2 · 12 kW — 40,944 BTU/h · 2 stages · breaker included |
| 48,000 BTU/h · AMUH48KUAS | UTZ-EU05MMA · 5 kW — 17,060 BTU/h · 1 stage · breaker included UTZ-EU08MMA · 8 kW — 27,296 BTU/h · 1 stage · breaker included UTZ-EU16MMB2 · 16 kW — 54,592 BTU/h · 2 stages · breaker included |
Fujitsu brochure and submittal sheets. LogisVert pays nothing for a heater kit.
Electric back-up is not dual energy.
Hydro-Québec’s Rate DT requires a fuel back-up. Pick your back-up to see what applies.
Fujitsu electric kit
| System type | All-electric |
| Rate DT (dual energy) | No: it requires a fuel back-up |
| LogisVert | The heat pump only; $0 for the back-up |
Hydro-Québec rates and LogisVert guide.
Electric baseboards
| System type | All-electric |
| Rate DT (dual energy) | No: it requires a fuel back-up |
| LogisVert | The heat pump only; $0 for the back-up |
Hydro-Québec suggests keeping a back-up, for example existing baseboards (user guide, 2026).
Natural gas furnace
| System type | Dual energy possible |
| Rate DT (dual energy) | Possible if the central heat pump is the main source and the fuel (natural gas) takes over below -12 °C or -15 °C depending on the region |
| Fujitsu | The Fujitsu documents read do not describe the Centauri with a fuel furnace: we discuss it during the visit. |
| Énergir | Énergir gas customers have their own dual-energy program, separate from this product. |
Oil
| System type | Dual energy possible |
| Rate DT (dual energy) | Possible if the central heat pump is the main source and the fuel (oil) takes over below -12 °C or -15 °C depending on the region |
| Fujitsu | The Fujitsu documents read do not describe the Centauri with a fuel furnace: we discuss it during the visit. |
Propane
| System type | Dual energy possible |
| Rate DT (dual energy) | Possible if the central heat pump is the main source and the fuel (propane) takes over below -12 °C or -15 °C depending on the region |
| Fujitsu | The Fujitsu documents read do not describe the Centauri with a fuel furnace: we discuss it during the visit. |
Wood pellets
| System type | Dual energy possible |
| Rate DT (dual energy) | Possible if the central heat pump is the main source and the fuel (pellets) takes over below -12 °C or -15 °C depending on the region |
| Fujitsu | The Fujitsu documents read do not describe the Centauri with a fuel furnace: we discuss it during the visit. |
From $1,272 to $4,464 in R-32.
All nine R-32 systems are ENERGY STAR cold climate: $120 per 1,000 BTU/h at -8 °C. For a central system, the unit and the ducts must stay inside the insulated envelope.
| Model | Indicative amount | Calculation |
|---|---|---|
| Centauri 12,000 | $1,272 | 10,600 BTU/h ÷ 1,000 × $120 = $1,272 |
| Centauri 18,000 | $1,932 | 16,100 BTU/h ÷ 1,000 × $120 = $1,932 |
| Centauri 24,000 | $2,184 | 18,200 BTU/h ÷ 1,000 × $120 = $2,184 |
| Centauri 30,000 | $2,664 | 22,200 BTU/h ÷ 1,000 × $120 = $2,664 |
| Centauri 36,000 | $3,288 | 27,400 BTU/h ÷ 1,000 × $120 = $3,288 |
| Centauri 48,000 | $4,464 | 37,200 BTU/h ÷ 1,000 × $120 = $4,464 |
| Centauri XLTH 30,000 | $2,520 | 21,000 BTU/h ÷ 1,000 × $120 = $2,520 |
| Centauri XLTH 36,000 | $3,024 | 25,200 BTU/h ÷ 1,000 × $120 = $3,024 |
| Centauri XLTH 48,000 | $4,080 | 34,000 BTU/h ÷ 1,000 × $120 = $4,080 |
Since November 26, 2025, only ENERGY STAR certified heat pumps qualify.
The outdoor unit must be at least 12,000 BTU/h nominal in cooling.
For a central system, the indoor unit must not be in the attic or outside the insulation plane.
You apply no later than nine months after installation.
July 8, 2027
Four questions before counting on LogisVert
- Will the indoor unit or the ducts be in the attic or roof space? No
- Does the house already have a geothermal system? No
- Are you replacing only the outdoor unit, the indoor unit or a coil? No
- Does the replacement follow a breakdown covered by a warranty or insurance? No
Seven R-410A systems, retired by Fujitsu.
They stay in AirGreen’s catalogue. Only two are on the ENERGY STAR list; the others get no LogisVert.
| Product | Units | ENERGY STAR | Indicative LogisVert | Same size in R-32 |
|---|---|---|---|---|
| 24LAMS1 Fujitsu name: 24RGLXM | AMUG24LMAS + AOU24RGLX | not listed | $0 | Centauri 24 000 |
| 30LAMS1 Fujitsu name: 30RGLXM | AMUG30LMAS + AOU30RGLX | not listed | $0 | Centauri 30 000 / Centauri XLTH 30 000 |
| 36LAMS1 Fujitsu name: 36LMAS1 | AMUG36LMAS + AOUG36LMAS1 | cold climate | $3,528 | Centauri 36 000 / Centauri XLTH 36 000 |
| 48LAMS1 Fujitsu name: 48LMAS1 | AMUG48LMAS + AOUG48LMAS1 | not listed | $0 | Centauri 48 000 / Centauri XLTH 48 000 |
| 30LUAH1M Fujitsu name: 30LUAH1M | AMUG30LMAS + AOUH30LUAH1 | cold climate | $2,592 | Centauri 30 000 / Centauri XLTH 30 000 |
| 36LMAH1M Fujitsu name: 36LMAH1M | AMUG36LMAS + AOUH36LMAH1 | not listed | $0 | Centauri 36 000 / Centauri XLTH 36 000 |
| 48LMAH1M Fujitsu name: 48LMAH1M | AMUG48LMAS + AOUH48LMAH1 | not listed | $0 | Centauri 48 000 / Centauri XLTH 48 000 |
Fujitsu lists these systems among its retired models. The store names (24LAMS1, 30LAMS1…) are not Fujitsu’s. The R-32 match is made by AirGreen at equal size; Fujitsu publishes none.
Wall controller, Wi-Fi or your 24 V thermostat.
| Type | Model | Role |
|---|---|---|
| Wired wall controller | UTY-RVRU | KAGAMI touch-panel wired controller |
| Wired wall controller | UTY-RNRUZ5 | touch-panel wired remote |
| Wired wall controller | UTY-RSRY | simple wired remote, with mode |
| Wired wall controller | UTY-RHRY | simple wired remote, no mode |
| Wireless | UTY-LBTUM | IR receiver kit with wireless remote |
| 24 V thermostat | UTY-TTRXZ1 | Interface for a 24 V thermostat; used with no other control, according to Fujitsu. |
| Sensor | UTY-XSZXZ1 | Remote temperature sensor |
Controls listed by Fujitsu for these units. The exact Wi-Fi adapter is confirmed at quote time (Fujitsu’s brochure and web page name different ones).
The nine R-32 systems, line by line.
A dash: value not verified in the Fujitsu sheets consulted, so not shown.
| Centauri 12,000 | Centauri 18,000 | Centauri 24,000 | Centauri 30,000 | Centauri 36,000 | Centauri 48,000 | Centauri XLTH 30,000 | Centauri XLTH 36,000 | Centauri XLTH 48,000 | |
|---|---|---|---|---|---|---|---|---|---|
| Indoor unit | AMUH12KUAS | AMUH18KUAS | AMUH24KUAS | AMUH30KUAS | AMUH36KUAS | AMUH48KUAS | AMUH30KUAS | AMUH36KUAS | AMUH48KUAS |
| Outdoor unit | AOUH12KUAS1 | AOUH18KUAS1 | AOUH24KUAS1 | AOUH30KUAS1 | AOUH36KUAS1 | AOUH48KUAS1 | AOUH30KUAH1 | AOUH36KUAH1 | AOUH48KUAH1 |
| AHRI number | 217290592 | 217290593 | 217290594 | 217290595 | 217290596 | 217290597 | 217895716 | 217895717 | 217895718 |
| Heats down to | -21 °C | -21 °C | -21 °C | -21 °C | -21 °C | -21 °C | -26 °C | -26 °C | -26 °C |
| Rated heating | 16,000 BTU/h | 21,600 BTU/h | 27,000 BTU/h | 32,000 BTU/h | 38,000 BTU/h | 51,000 BTU/h | 32,000 BTU/h | 38,000 BTU/h | 51,000 BTU/h |
| Rated cooling | 12,000 BTU/h | 18,000 BTU/h | 24,000 BTU/h | 30,000 BTU/h | 36,000 BTU/h | 45,500 BTU/h | 30,000 BTU/h | 36,000 BTU/h | 45,500 BTU/h |
| SEER2 | 19.9 | 19.2 | 17.7 | 19 | 17.6 | 17 | 18.8 | 18.3 | 19 |
| EER2 | 13 | 12.2 | 11.8 | 11.7 | 10.6 | 9.5 | 12.2 | 11.4 | 11.2 |
| HSPF2 | 10.3 | 10.5 | 10.1 | 10 | 9.8 | 9.6 | 10 | 10.2 | 10.2 |
| Indoor sound (min / max) | 31 / 42 dB(A) | 33 / 44 dB(A) | 29 / 42 dB(A) | 32 / 42 dB(A) | 31 / 44 dB(A) | 34 / 49 dB(A) | 32 / 42 dB(A) | 31 / 44 dB(A) | 34 / 49 dB(A) |
| Outdoor sound | 49 dB(A) | 55 dB(A) | 54 dB(A) | 55 dB(A) | 56 dB(A) | 59 dB(A) | – | – | – |
| Indoor, w×h×d | 444×1,092×533 mm | 444×1,092×533 mm | 444×1,092×533 mm | 533×1,219×533 mm | 533×1,219×533 mm | 533×1,219×533 mm | 533×1,219×533 mm | 533×1,219×533 mm | 533×1,219×533 mm |
| Outdoor, w×h×d | 799×632×290 mm | 799×632×290 mm | 940×788×320 mm | 940×998×320 mm | 940×998×320 mm | 940×998×320 mm | – | – | – |
| Weight in / out | 45.8 / 38 kg | 48.5 / 38 kg | 49.9 / 52 kg | 62.1 / 62 kg | 62.1 / 62 kg | 62.1 / 71 kg | 62.1 / – kg | 62.1 / – kg | 62.1 / – kg |
| Max line set / height | 30 / 15 m | 30 / 15 m | 50 / 30 m | 50 / 30 m | 50 / 30 m | 75 / 30 m | – / – m | – / – m | – / – m |
| Breaker | 15 A | 20 A | 20 A | 25 A | 25 A | 30 A | – | – | – |
| Refrigerant charge | 1.0 kg | 1.2 kg | 1.5 kg | 2 kg | 2 kg | 2.7 kg | – | – | – |
| ENERGY STAR | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate |
| Indicative LogisVert | $1,272 | $1,932 | $2,184 | $2,664 | $3,288 | $4,464 | $2,520 | $3,024 | $4,080 |
What Fujitsu’s sheets tell.
The same FUJITSU outdoor unit can serve several types of non-wall indoor units.
Source: FujitsuFujitsu’s largest back-up kit, 16 kW, gives about 54,600 BTU/h, more than the rated heating output of the 4-ton heat pump.
Source: Fujitsu, U.S. EIA, ENERGY STARFujitsu’s minimum heat mode holds the home at 10 °C to keep it above freezing.
Source: FujitsuMoving from R-410A to R-32 cuts the global warming potential from 2,088 to 675.
Source: ENERGY STARENERGY STAR files these systems as "Mini or Multi Split", while Hydro-Québec calls them central split heat pumps.
Source: ENERGY STAR, Hydro-QuébecFujitsu states an air leakage rate of less than 2% for its 36,000 BTU/h multi-position indoor unit.
Source: FujitsuFujitsu’s R-32 lines carry sky names: Altair, Orion, Aquila and Centauri.
Source: Fujitsu, NASA, IAUUp to 12 years on parts and compressor.
The longest tier needs online registration within 60 days and a Fujitsu Elite contractor. At AirGreen, both are done for you.
In Québec, the basic warranty needs no registration; the 10- and 12-year tiers do. Source: Fujitsu limited warranty statement (R-32).
We register your unit with Fujitsu, free, on time.
The condition for the 12-year tier. AirGreen is Elite Plus.
The warranty requires a licensed contractor. RBQ 5645-9605-01.
Fujitsu’s text excludes systems bought from an online retailer.
Fujitsu’s central systems, AirGreen’s ducts.
A central system heats the whole house if the ducts can carry it. AirGreen inspects the duct system, picks the series, the size and the back-up, installs and registers the warranty.
What FUJITSU AIRSTAGE brings
- Two R-32 seriesCentauri and Centauri XLTH.
- Down to -26 °CWith the Centauri XLTH.
- ENERGY STAR cold climateAll nine R-32 systems.
- Up to 12 yearsParts and compressor, on Fujitsu’s conditions.
What AirGreen brings
- Elite Plus dealerThe highest level of the AIRSTAGE Elite program.
- Free home estimateWe measure and check the insulation and the location.
- Warranty registered for youWith Fujitsu, within 60 days.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: a central system of the right size and series for your winter.
Recent installations, in photos.
Each article on our blog tells a real installation: the place, the constraint and the solution.






Elite Plus: the highest level of the AIRSTAGE Elite program.
Fujitsu’s Japanese engineering, installed by an Elite Plus team across Montreal, Laval, Longueuil, the North Shore, the South Shore and Montérégie.
The highest level of the AIRSTAGE Elite program.
Our technicians take the manufacturer’s training on AIRSTAGE systems.
Vacuum, refrigerant settings, electrical hookup, set up for winter.
Manufacturer parts and Fujitsu technical support, wherever we install.
Free. We measure and check the insulation and the location.
The model, the size and the indicative LogisVert amount, in writing.
Vacuum, refrigerant, electrical, winter settings.
We register the unit with Fujitsu and help you with LogisVert.
What people ask us about Fujitsu central systems.
No question matches. Call us at 514 316-2973.
An inverter outdoor unit connected to a multi-position air handler (AMUH) that delivers heating and cooling to the whole home through the ducts.
The Centauri heats down to -21 °C and comes in 1 to 4 tons. The XLTH heats down to -26 °C, comes in 2.5, 3 and 4 tons, and keeps more heat in the cold: 51,000 BTU/h at -15 °C in the 48,000, against 41,000 for the Centauri.
In the basement, a closet or a crawl space: it installs upflow, downflow with a kit, or horizontal. For LogisVert, it must stay inside the home’s insulated envelope, not in the attic.
It has to be checked on site. Fujitsu’s indoor unit works with external static pressure of 0.08 to 0.80 in. WG (small cabinet) or 0.2 to 0.8 in. WG (medium cabinet).
Yes. The guide accepts a new ducted split (central) air-to-air heat pump, ENERGY STAR certified, of at least 12,000 BTU/h nominal, installed by a business holding the appropriate RBQ licence.
From $1,272 to $4,464 depending on the model, at $120 per 1,000 BTU/h at -8 °C. The amount never exceeds the pre-tax cost.
Not with LogisVert: replacing a single coil or a single indoor or outdoor unit is not eligible.
No. The guide excludes installing or replacing a central heat pump in a home that has a geothermal system.
Fujitsu offers 2 to 16 kW electric kits that fit inside the indoor unit, on a dedicated circuit. Back-up heat switches on automatically.
No. Rate DT requires a fuel back-up: natural gas, oil, propane or wood pellets. A heat pump with electric back-up remains an all-electric system.
No. Natural Resources Canada states that the Canada Greener Homes Grant is closed.
Fujitsu lists the AMUG air handlers of that generation as retired. Only two combinations are still in the ENERGY STAR list.
Related collections.
Six sizes from 1 to 4 tons, heating down to -21 °C.
View the collectionCentralCentauri XLTHThree sizes from 2.5 to 4 tons, heating down to -26 °C.
View the collectionCentralAir handlersFUJITSU electric furnaces made to work with the Centauri.
View the collectionIndoor unitDucted unitsOther FUJITSU ducted indoor units that work with the same family of outdoor units.
View the collectionWall unitsWall heat pumpsWithout ducts, FUJITSU wall heat pumps heat room by room.
View the collectionMulti-zoneMulti-zone heat pumpsOne outdoor unit for several rooms, without ducts.
View the collectionYour Fujitsu central system, installed by an Elite Plus team.
We come and look at the ducts and the electrical panel, choose the series, the size and the back-up, and give you a clear quote with the indicative LogisVert amount.
Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump: hang up.
Sources checked on October 8, 2026
33 sources · show
- Fujitsu AIRSTAGE, airstagehvac.com/r32/kuas1m
- Fujitsu, product or archive page AS-MIRROR
- Fujitsu AIRSTAGE, airstagehvac.com/technology/xlth-low-temp-heating
- Fujitsu AIRSTAGE, airstagehvac.com/split/featureicon
- Fujitsu, brochure FG8161C
- Fujitsu, submittal sheet 12KUAS1M
- Fujitsu, submittal sheet 18KUAS1M
- Fujitsu, submittal sheet 24KUAS1M
- Fujitsu, submittal sheet 30KUAS1M
- Fujitsu, submittal sheet 36KUAS1M
- Fujitsu, submittal sheet 48KUAS1M
- Fujitsu AIRSTAGE, document pdf-fcus-h-series-warranty-r32-202606
- Fujitsu AIRSTAGE, airstagehvac.com/contractor/elite-contractor-program
- Fujitsu, product or archive page LEG-IDX
- Fujitsu, product or archive page LEG-RET
- Fujitsu, product or archive page LEG-PAGES
- ENERGY STAR, certified air-source heat pump list (dataset w7cv-9xjt)
- NEEP, cold-climate heat pump list
- Hydro-Québec, logisvert guide participation residentiel fr
- Hydro-Québec, logisvert energy star heat pumps
- Hydro-Québec, LogisVert residential participation guide, version 1.10
- Hydro-Québec, rate DT (dual energy)
- Government of Québec, quebec adopte un reglement afin deliminer le recours au mazout pour le chauffage residentiel 36186
- Government of Canada, closed canada greener homes grant
- Government of Canada, climate_normals
- U.S. EIA, british thermal units.php
- U.S. NIH, NIDCD, noise induced hearing loss
- International Astronomical Union, star and constellation names
- NASA, nearest_star_info
- NASA, proxima centauri b
- Trade press, buildings.com
- airgreen.ca product sheets, read October 8, 2026
- AirGreen, “Nos réalisations” projects blog
Amounts shown are estimates; only Hydro-Québec confirms the grant. Manufacturer data is quoted “according to Fujitsu”.
Every central system, right below.
Each product sheet gives the AHRI number, the rated capacity and the indicative LogisVert amount.