FUJITSU electric furnace: the AMUH air handler and its 2 to 16 kW back-up.
What people call a Fujitsu “furnace” is the air handler of the Centauri central heat pump. A kit of electric elements slides into it: the heat pump heats first, the back-up takes over when it is no longer enough.
Not a furnace: an air handler
Fujitsu sells no “furnace”. The AMUH unit blows the central heat pump’s air; the UTZ-EU kit adds electric elements for back-up.
A heat pump, then a back-up.
Seven facts from Fujitsu’s brochure and sheets, Hydro-Québec’s rates and the LogisVert guide. Sources are at the bottom of the page.
Fujitsu doesn’t sell a "furnace": it’s the AMUH air handler, with an added electric heater kit of 2 to 16 kW.
Each size has its own kits: up to 4 kW on the 12,000 BTU/h model, up to 16 kW on the 48,000 BTU/h model.
The 16 kW kit gives about 54,600 BTU/h, more than the 51,000 BTU/h rating of the 48,000 heat pump at 8.3 °C.
A heat pump with electric backup is an all-electric system. Hydro-Québec’s Rate DT requires a fuel backup instead.
LogisVert funds the ENERGY STAR certified heat pump. The program guide sets no amount for a furnace or electric elements.
Backup heat turns on automatically when the heat pump can’t keep up, and there is an emergency heat mode.
Every kit needs a dedicated circuit, and some ship without a breaker.
The unit, the kit, the heat pump.
What is sold as a Fujitsu “electric furnace”, part by part.
The fan and the coil, in a cabinet that installs upright or lying down. It blows warm or cool air into your ducts.
Electric elements from 2 to 16 kW that slide into the unit, on a dedicated circuit.
The Centauri or Centauri XLTH outdoor unit. It heats first, and it is what LogisVert funds.
Then the back-up, when it gets colder.
Pick a system: what the heat pump gives at each published temperature, and what the largest kit adds. The back-up turns on automatically, according to Fujitsu.
Centauri 12
| Heat pump at 8.3 °C | 16,000 BTU/h · rated |
| Heat pump at -8.3 °C | 10,600 BTU/h · rated |
| Heat pump at -15 °C | 16,100 BTU/h · ENERGY STAR |
| Heat pump at -20.6 °C | 14,520 BTU/h · maximum, NEEP |
| Largest kit (4 kW) | about 13,600 BTU/h |
| Below -21 °C | capacity not published: the kit takes over |
Values from Fujitsu, ENERGY STAR and NEEP; the kit in BTU/h is a conversion (1 kW = 3,412 BTU/h). Fujitsu publishes no switch-over temperature in the documents read: we set it with you.
Centauri 18
| Heat pump at 8.3 °C | 21,600 BTU/h · rated |
| Heat pump at -8.3 °C | 16,100 BTU/h · rated |
| Heat pump at -15 °C | 17,300 BTU/h · ENERGY STAR |
| Heat pump at -20.6 °C | 14,570 BTU/h · maximum, NEEP |
| Largest kit (6 kW) | about 20,500 BTU/h |
| Below -21 °C | capacity not published: the kit takes over |
Values from Fujitsu, ENERGY STAR and NEEP; the kit in BTU/h is a conversion (1 kW = 3,412 BTU/h). Fujitsu publishes no switch-over temperature in the documents read: we set it with you.
Centauri 24
| Heat pump at 8.3 °C | 27,000 BTU/h · rated |
| Heat pump at -8.3 °C | 18,200 BTU/h · rated |
| Heat pump at -15 °C | 24,600 BTU/h · ENERGY STAR |
| Heat pump at -20.6 °C | 21,860 BTU/h · maximum, NEEP |
| Largest kit (8 kW) | about 27,300 BTU/h |
| Below -21 °C | capacity not published: the kit takes over |
Values from Fujitsu, ENERGY STAR and NEEP; the kit in BTU/h is a conversion (1 kW = 3,412 BTU/h). Fujitsu publishes no switch-over temperature in the documents read: we set it with you.
Centauri 30
| Heat pump at 8.3 °C | 32,000 BTU/h · rated |
| Heat pump at -8.3 °C | 22,200 BTU/h · rated |
| Heat pump at -15 °C | 29,400 BTU/h · ENERGY STAR |
| Heat pump at -20.6 °C | 25,190 BTU/h · maximum, NEEP |
| Largest kit (10 kW) | about 34,100 BTU/h |
| Below -21 °C | capacity not published: the kit takes over |
Values from Fujitsu, ENERGY STAR and NEEP; the kit in BTU/h is a conversion (1 kW = 3,412 BTU/h). Fujitsu publishes no switch-over temperature in the documents read: we set it with you.
Centauri 36
| Heat pump at 8.3 °C | 38,000 BTU/h · rated |
| Heat pump at -8.3 °C | 27,400 BTU/h · rated |
| Heat pump at -15 °C | 32,000 BTU/h · ENERGY STAR |
| Heat pump at -20.6 °C | 27,850 BTU/h · maximum, NEEP |
| Largest kit (12 kW) | about 40,900 BTU/h |
| Below -21 °C | capacity not published: the kit takes over |
Values from Fujitsu, ENERGY STAR and NEEP; the kit in BTU/h is a conversion (1 kW = 3,412 BTU/h). Fujitsu publishes no switch-over temperature in the documents read: we set it with you.
Centauri 48
| Heat pump at 8.3 °C | 51,000 BTU/h · rated |
| Heat pump at -8.3 °C | 37,200 BTU/h · rated |
| Heat pump at -15 °C | 41,000 BTU/h · ENERGY STAR |
| Heat pump at -20.6 °C | 37,960 BTU/h · maximum, NEEP |
| Largest kit (16 kW) | about 54,600 BTU/h |
| Below -21 °C | capacity not published: the kit takes over |
Values from Fujitsu, ENERGY STAR and NEEP; the kit in BTU/h is a conversion (1 kW = 3,412 BTU/h). Fujitsu publishes no switch-over temperature in the documents read: we set it with you.
Centauri XLTH 30
| Heat pump at 8.3 °C | 32,000 BTU/h · rated |
| Heat pump at -8.3 °C | 21,000 BTU/h · rated |
| Heat pump at -15 °C | 34,000 BTU/h · ENERGY STAR |
| Heat pump at -26.1 °C | 26,000 BTU/h · maximum, NEEP |
| Largest kit (10 kW) | about 34,100 BTU/h |
| Below -26 °C | capacity not published: the kit takes over |
Values from Fujitsu, ENERGY STAR and NEEP; the kit in BTU/h is a conversion (1 kW = 3,412 BTU/h). Fujitsu publishes no switch-over temperature in the documents read: we set it with you.
Centauri XLTH 36
| Heat pump at 8.3 °C | 38,000 BTU/h · rated |
| Heat pump at -8.3 °C | 25,200 BTU/h · rated |
| Heat pump at -15 °C | 41,000 BTU/h · ENERGY STAR |
| Heat pump at -26.1 °C | 32,000 BTU/h · maximum, NEEP |
| Largest kit (12 kW) | about 40,900 BTU/h |
| Below -26 °C | capacity not published: the kit takes over |
Values from Fujitsu, ENERGY STAR and NEEP; the kit in BTU/h is a conversion (1 kW = 3,412 BTU/h). Fujitsu publishes no switch-over temperature in the documents read: we set it with you.
Centauri XLTH 48
| Heat pump at 8.3 °C | 51,000 BTU/h · rated |
| Heat pump at -8.3 °C | 34,000 BTU/h · rated |
| Heat pump at -15 °C | 51,000 BTU/h · ENERGY STAR |
| Heat pump at -26.1 °C | 51,000 BTU/h · maximum, NEEP |
| Largest kit (16 kW) | about 54,600 BTU/h |
| Below -26 °C | capacity not published: the kit takes over |
Values from Fujitsu, ENERGY STAR and NEEP; the kit in BTU/h is a conversion (1 kW = 3,412 BTU/h). Fujitsu publishes no switch-over temperature in the documents read: we set it with you.
From 2 to 16 kW, depending on the unit.
Pick a unit size: its kits. The full catalogue follows.
| Indoor unit | Fujitsu kits |
|---|---|
| 12,000 BTU/h · AMUH12KUAS | UTZ-EU02MSA · 2 kW — 6,824 BTU/h · 1 stage · breaker field-supplied UTZ-EU04MSB2 · 4 kW — 13,648 BTU/h · 2 stages · breaker field-supplied |
| 18,000 BTU/h · AMUH18KUAS | UTZ-EU03MSA · 3 kW — 10,236 BTU/h · 1 stage · breaker included UTZ-EU06MSB2 · 6 kW — 20,472 BTU/h · 2 stages · breaker field-supplied |
| 24,000 BTU/h · AMUH24KUAS | UTZ-EU02MSA · 2 kW — 6,824 BTU/h · 1 stage · breaker field-supplied UTZ-EU04MSA · 4 kW — 13,648 BTU/h · 1 stage · breaker included UTZ-EU08MSB2 · 8 kW — 27,296 BTU/h · 2 stages · breaker field-supplied |
| 30,000 BTU/h · AMUH30KUAS | UTZ-EU03MMA · 3 kW — 10,236 BTU/h · 1 stage · breaker included UTZ-EU05MMA · 5 kW — 17,060 BTU/h · 1 stage · breaker included UTZ-EU10MMB2 · 10 kW — 34,120 BTU/h · 2 stages · breaker included |
| 36,000 BTU/h · AMUH36KUAS | UTZ-EU03MMA · 3 kW — 10,236 BTU/h · 1 stage · breaker included UTZ-EU06MMA · 6 kW — 20,472 BTU/h · 1 stage · breaker included UTZ-EU12MMB2 · 12 kW — 40,944 BTU/h · 2 stages · breaker included |
| 48,000 BTU/h · AMUH48KUAS | UTZ-EU05MMA · 5 kW — 17,060 BTU/h · 1 stage · breaker included UTZ-EU08MMA · 8 kW — 27,296 BTU/h · 1 stage · breaker included UTZ-EU16MMB2 · 16 kW — 54,592 BTU/h · 2 stages · breaker included |
Each kit needs a dedicated circuit; some ship without a breaker, supplied on site.
| Kit | Power | About | Stages | Breaker | Units |
|---|---|---|---|---|---|
| UTZ-EU02MSA | 2 kW | 6,824 BTU/h | 1 | field-supplied | AMUH12KUAS, AMUH24KUAS |
| UTZ-EU03MSA | 3 kW | 10,236 BTU/h | 1 | included | AMUH18KUAS |
| UTZ-EU04MSA | 4 kW | 13,648 BTU/h | 1 | included | AMUH24KUAS |
| UTZ-EU04MSB2 | 4 kW | 13,648 BTU/h | 2 | field-supplied | AMUH12KUAS |
| UTZ-EU06MSB2 | 6 kW | 20,472 BTU/h | 2 | field-supplied | AMUH18KUAS |
| UTZ-EU08MSB2 | 8 kW | 27,296 BTU/h | 2 | field-supplied | AMUH24KUAS |
| UTZ-EU03MMA | 3 kW | 10,236 BTU/h | 1 | included | AMUH30KUAS, AMUH36KUAS |
| UTZ-EU05MMA | 5 kW | 17,060 BTU/h | 1 | included | AMUH30KUAS, AMUH48KUAS |
| UTZ-EU06MMA | 6 kW | 20,472 BTU/h | 1 | included | AMUH36KUAS |
| UTZ-EU08MMA | 8 kW | 27,296 BTU/h | 1 | included | AMUH48KUAS |
| UTZ-EU10MMB2 | 10 kW | 34,120 BTU/h | 2 | included | AMUH30KUAS |
| UTZ-EU12MMB2 | 12 kW | 40,944 BTU/h | 2 | included | AMUH36KUAS |
| UTZ-EU16MMB2 | 16 kW | 54,592 BTU/h | 2 | included | AMUH48KUAS |
Fujitsu brochure. BTU/h is a conversion (1 kW = 3,412 BTU/h), not a Fujitsu rating. Each kit needs a dedicated circuit.
Four positions, two cabinets.
Upright in the basement, lying in a crawl space: only downflow needs a kit.
In the basement, air rises into the ducts. No kit.
Kit required: UTD-DFMSB1 (12,000 to 24,000) or UTD-DFMMB1 (30,000 to 48,000).
Lying in a crawl space or ceiling, outlet to the left.
Same, outlet to the right.
| Cabinet | Sizes | w×h×d | Static pressure | Filter base |
|---|---|---|---|---|
| Small cabinet | 12,000, 18,000 and 24,000 BTU/h | 444×1,092×533 mm | 0.08–0.8 in. w.c. | 86ET0002 · 16×20 in. |
| Medium cabinet | 30,000, 36,000 and 48,000 BTU/h | 533×1,219×533 mm | 0.2–0.8 in. w.c. | 86ET0001 · 20×20 in. |
Fujitsu submittal sheets and brochure. Clearances are not published in the documents read: we confirm them on site.
The unit and its heat pump.
Tap a system: photo, sheet, efficiency and LogisVert amount. The last four are the previous R-410A generation.
Electric back-up is not dual energy.
Pick your back-up: what Hydro-Québec’s rates and LogisVert say about it.
Fujitsu electric kit
| System type | All-electric |
| Rate DT (dual energy) | No: it requires a fuel back-up |
| LogisVert | The heat pump only; $0 for the back-up |
Hydro-Québec rates and LogisVert guide.
Electric baseboards
| System type | All-electric |
| Rate DT (dual energy) | No: it requires a fuel back-up |
| LogisVert | The heat pump only; $0 for the back-up |
Hydro-Québec suggests keeping a back-up, for example existing baseboards (user guide, 2026).
Natural gas furnace
| System type | Dual energy possible |
| Rate DT (dual energy) | Possible if the central heat pump is the main source and the fuel (natural gas) takes over below -12 °C or -15 °C depending on the region |
| Fujitsu | The Fujitsu documents read do not describe the Centauri with a fuel furnace: we discuss it during the visit. |
| Énergir | Énergir gas customers have their own dual-energy program, separate from this product. |
Oil
| System type | Dual energy possible |
| Rate DT (dual energy) | Possible if the central heat pump is the main source and the fuel (oil) takes over below -12 °C or -15 °C depending on the region |
| Fujitsu | The Fujitsu documents read do not describe the Centauri with a fuel furnace: we discuss it during the visit. |
Propane
| System type | Dual energy possible |
| Rate DT (dual energy) | Possible if the central heat pump is the main source and the fuel (propane) takes over below -12 °C or -15 °C depending on the region |
| Fujitsu | The Fujitsu documents read do not describe the Centauri with a fuel furnace: we discuss it during the visit. |
Wood pellets
| System type | Dual energy possible |
| Rate DT (dual energy) | Possible if the central heat pump is the main source and the fuel (pellets) takes over below -12 °C or -15 °C depending on the region |
| Fujitsu | The Fujitsu documents read do not describe the Centauri with a fuel furnace: we discuss it during the visit. |
The heat pump, not the furnace.
The LogisVert guide pays nothing for a furnace or electric elements. The amount comes from the ENERGY STAR certified heat pump.
| Model | Indicative amount | Calculation |
|---|---|---|
| Centauri 12 | $1,272 | 10,600 BTU/h ÷ 1,000 × $120 = $1,272 |
| Centauri 18 | $1,932 | 16,100 BTU/h ÷ 1,000 × $120 = $1,932 |
| Centauri 24 | $2,184 | 18,200 BTU/h ÷ 1,000 × $120 = $2,184 |
| Centauri 30 | $2,664 | 22,200 BTU/h ÷ 1,000 × $120 = $2,664 |
| Centauri 36 | $3,288 | 27,400 BTU/h ÷ 1,000 × $120 = $3,288 |
| Centauri 48 | $4,464 | 37,200 BTU/h ÷ 1,000 × $120 = $4,464 |
| Centauri XLTH 30 | $2,520 | 21,000 BTU/h ÷ 1,000 × $120 = $2,520 |
| Centauri XLTH 36 | $3,024 | 25,200 BTU/h ÷ 1,000 × $120 = $3,024 |
| Centauri XLTH 48 | $4,080 | 34,000 BTU/h ÷ 1,000 × $120 = $4,080 |
Since November 26, 2025, only ENERGY STAR certified heat pumps qualify.
The outdoor unit must be at least 12,000 BTU/h nominal in cooling.
For a central system, the indoor unit must not be in the attic or outside the insulation plane.
You apply no later than nine months after installation.
July 8, 2027
The 48,000 paradox
Three RBQ licences, one installation.
The unit, the heat pump and the kit circuit fall under three licence subclasses.
Forced-air heating devices and their ducts: the AMUH unit and the duct system.
Refrigeration: the heat pump and its refrigerant lines.
Electrical: the heater kit’s dedicated circuit.
RBQ 5645-9605-01: all three subclasses, so the whole installation by the same team.
What Fujitsu’s sheets tell.
Fujitsu’s "electric furnace" is an air handler that installs in four positions.
Source: FujitsuThe 16 kW kit gives about 54,600 BTU/h, more than the 48,000 heat pump at 8.3 °C.
Source: Fujitsu, U.S. EIA, ENERGY STARThe 48,000 Centauri XLTH keeps 51,000 BTU/h at -15 °C, the same as at 8.3 °C.
Source: ENERGY STARHydro-Québec’s Rate DT requires a fuel backup; electric backup doesn’t qualify.
Source: Hydro-QuébecSome Fujitsu heater kits ship without a breaker; it’s supplied on site.
Source: FujitsuTwo-stage kits bring the backup on in two steps instead of all at once.
Source: FujitsuThe Fujitsu system has a minimum heat mode at 10 °C to keep a cottage above freezing.
Source: FujitsuUp to 12 years on parts and compressor.
The longest tier needs online registration within 60 days and a Fujitsu Elite contractor. At AirGreen, both are done for you.
In Québec, the basic warranty needs no registration; the 10- and 12-year tiers do. Source: Fujitsu limited warranty statement (R-32).
We register your unit with Fujitsu, free, on time.
The condition for the 12-year tier. AirGreen is Elite Plus.
The warranty requires a licensed contractor. RBQ 5645-9605-01.
Fujitsu’s text excludes systems bought from an online retailer.
Fujitsu’s unit, AirGreen’s circuit.
A 16 kW kit means a dedicated circuit and a panel that can take it. AirGreen checks the panel, installs the air handler, the heat pump and the kit, and registers the warranty.
What FUJITSU AIRSTAGE brings
- AMUH unitFour positions, two cabinets.
- 2 to 16 kWThirteen UTZ-EU kits.
- Automatic back-upAnd an emergency heat mode.
- Up to 12 yearsHeat pump parts and compressor, on Fujitsu’s conditions.
What AirGreen brings
- Elite Plus dealerThe highest level of the AIRSTAGE Elite program.
- Free home estimateWe measure and check the insulation and the location.
- Warranty registered for youWith Fujitsu, within 60 days.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: a central heat pump that heats first, and a back-up ready for the coldest nights.
Centauri units and their AMUH air handler, in photos.
Real installations of the AMUH unit with its heat pump. The electric back-up is not always part of them: every project is different.






Elite Plus: the highest level of the AIRSTAGE Elite program.
Fujitsu’s Japanese engineering, installed by an Elite Plus team across Montreal, Laval, Longueuil, the North Shore, the South Shore and Montérégie.
The highest level of the AIRSTAGE Elite program.
Our technicians take the manufacturer’s training on AIRSTAGE systems.
Vacuum, refrigerant settings, electrical hookup, set up for winter.
Manufacturer parts and Fujitsu technical support, wherever we install.
Free. We measure and check the insulation and the location.
The model, the size and the indicative LogisVert amount, in writing.
Vacuum, refrigerant, electrical, winter settings.
We register the unit with Fujitsu and help you with LogisVert.
What people ask us about the Fujitsu electric furnace.
No question matches. Call us at 514 316-2973.
It’s the AMUH multi-position air handler, the indoor part of the Centauri central heat pump. You can add a 2 to 16 kW electric heater kit, depending on the size. The heat pump heats and cools; the elements take over in deep cold.
Fujitsu offers up to 4 kW for the 12,000 BTU/h, 6 kW for the 18,000, 8 kW for the 24,000, 10 kW for the 30,000, 12 kW for the 36,000 and 16 kW for the 48,000. We pick the kit based on your heating load and your electrical service.
No. LogisVert pays for the ENERGY STAR certified heat pump, based on its capacity at -8 °C. The program guide sets no amount for a furnace or electric elements.
No. Rate DT requires a fuel backup: natural gas, oil, propane or wood pellets. A heat pump with electric backup is an all-electric system.
The Fujitsu system brings on the backup automatically when the heat pump can’t keep up. It also has an emergency heat mode. The exact setting is made at installation.
Yes. Fujitsu requires a dedicated power supply for the heater kit, and some kits don’t include a breaker. Our electricians handle it.
Centauri: down to -21 °C. Centauri XLTH: down to -26 °C. In the 48,000 size, the XLTH still delivers 51,000 BTU/h at -15 °C.
The unit installs upflow, downflow (with a kit) or horizontal, left or right. For LogisVert, the indoor unit and its ducts must stay inside the insulated envelope, so not in an attic.
Often, yes. The 12,000 to 24,000 BTU/h sizes handle 0.08 to 0.80 in. of water column, and the 30,000 to 48,000 sizes 0.2 to 0.8 in. We check your ducts before confirming.
Yes, with Fujitsu’s UTY-TTRXZ1 24 V interface. It must then be the only control on the system.
Fujitsu covers parts for 5 years and the compressor for 7. With online registration within 60 days it’s 10 years, and 12 years when installed by a Fujitsu Elite contractor. Labour isn’t included in the manufacturer’s warranty.
The heat pump supplies the heat most of the time, and the ducts spread the air through the house. The furnace elements are only backup. With baseboards, each room heats on its own.
Related collections.
All FUJITSU central heat pumps, including the outdoor unit that goes with this air handler.
View the collectionCentralCentauriThe Centauri central heat pump, which heats down to -21 °C with this air handler.
View the collectionCentralCentauri XLTHThe XLTH version, which heats down to -26 °C with the same air handler.
View the collectionControlsThermostats and controlsFujitsu wall controls, including one with emergency heat control, and the 24 V thermostat interface.
View the collectionPartsParts and accessoriesHeater kits, downflow kits and filter bases for the AMUH air handler.
View the collectionIndoor unitDucted unitsOther FUJITSU ducted indoor units.
View the collectionYour AMUH unit and its back-up, installed by an Elite Plus team.
We come and look at the ducts and the electrical panel, choose the heat pump and the kit, and give you a clear quote.
Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump: hang up.
Sources checked on October 8, 2026
39 sources · show
- Fujitsu AIRSTAGE, airstagehvac.com/r32/kuas1m
- Fujitsu AIRSTAGE, airstagehvac.com/split/featureicon
- Fujitsu, product or archive page AS-MIRROR
- Fujitsu AIRSTAGE, airstagehvac.com/technology/xlth-low-temp-heating
- Fujitsu, brochure FG8161C
- Fujitsu AIRSTAGE, airstagehvac.com/contractor/elite-contractor-program
- Fujitsu, product or archive page LEG-IDX
- Fujitsu, product or archive page LEG-PAGES
- Fujitsu, product or archive page LEG-RET
- Fujitsu AIRSTAGE, airstagehvac.com/controller/uty-rnru
- Fujitsu, submittal sheet 12KUAS1M
- Fujitsu, submittal sheet 18KUAS1M
- Fujitsu, submittal sheet 24KUAS1M
- Fujitsu, submittal sheet 30KUAS1M
- Fujitsu, submittal sheet 36KUAS1M
- Fujitsu, submittal sheet 48KUAS1M
- Fujitsu, technical sheet AMUG48LMAS-SUB_IN (distributor copy)
- Fujitsu AIRSTAGE, document pdf-fcus-h-series-warranty-r32-202606
- ENERGY STAR, certified air-source heat pump list (dataset w7cv-9xjt)
- NEEP, cold-climate heat pump list
- Hydro-Québec, option credit hivernal
- Hydro-Québec, rate DT (dual energy)
- Hydro-Québec, logisvert energy star heat pumps
- Hydro-Québec, Flex rate
- Hydro-Québec, LogisVert residential participation guide, version 1.10
- Hydro-Québec, logisvert guide participation residentiel fr
- Government of Canada, closed canada greener homes grant
- Régie du bâtiment du Québec, subclass 15.10
- Régie du bâtiment du Québec, subclass 15.8
- Régie du bâtiment du Québec, subclass 16
- U.S. EIA, british thermal units.php
- U.S. NIH, NIDCD, noise induced hearing loss
- NASA, nearest_star_info
- NASA, proxima centauri b
- International Astronomical Union, star and constellation names
- Trade press, buildings.com
- Énergir, dual energy
- airgreen.ca product sheets, read October 8, 2026
- AirGreen, “Nos réalisations” projects blog
Amounts shown are estimates; only Hydro-Québec confirms the grant. Manufacturer data is quoted “according to Fujitsu”.