Installation of a Fujitsu AIRSTAGE Aquila XLTH dual-zone heat pump in Saint-Constant, on Montreal’s South Shore
In Saint-Constant, we installed a Fujitsu AIRSTAGE Aquila XLTH dual-zone heat pump with a sleek wall-mounted unit, accessible controls, and a configuration designed to provide precise comfort in two areas of the home.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A wall-mounted unit precisely installed in a simple, functional residential space
In Saint-Constant, we installed a Fujitsu AIRSTAGE Aquila XLTH dual-zone heat pump to improve the comfort of two distinct areas of the property using a single outdoor unit. This configuration makes it possible to heat and cool two zones from the same compressor while providing individual control of each indoor unit.
The photograph shows one of the wall-mounted units installed in a room with light-coloured walls, a standard ceiling, and few visible architectural features. This type of environment may seem simple, but it still requires careful planning. The choice of location directly affects air circulation, ease of maintenance, acoustic comfort, and the visual quality of the result.
The Fujitsu unit was positioned high on the wall, slightly to the left of the centre of the available section. This arrangement keeps the lower part clear for furniture while ensuring sufficient air coverage in the room. A wall controller is visible on the right, making it easier to access the settings without constantly having to handle a remote control.
This project illustrates our approach at AirGreen: we do not simply install a machine. We adapt each HVAC installation to the reality of the building, the occupants’ habits, and the physical constraints of the space.
Why a dual-zone heat pump was suitable for this property
A dual-zone heat pump connects two indoor units to a single outdoor unit. This solution is particularly suitable for homes where two areas have different needs.
For example:
- of a living room and a bedroom;
- of a ground floor and an upper floor;
- of an open-concept area and an office;
- of an older section and an addition;
- of two rooms with different sun exposure;
- of a main living area and a less frequently used zone.
In Saint-Constant, many properties combine open-concept rooms with enclosed bedrooms or finished basements. A single wall-mounted unit is not always enough to distribute air evenly throughout the house. A dual-zone configuration can therefore treat each area more precisely.
Fujitsu documentation for AIRSTAGE H Series multi-zone systems indicates that a single outdoor unit can power several indoor units. Each indoor unit can be controlled independently, allowing the temperature to be adjusted according to the specific needs of each room.
A high installation to promote air distribution
The unit visible in the photo is installed near the ceiling while maintaining clearance above the cabinet. This clearance is essential because room air enters the appliance through its upper section before passing through the filters and heat exchanger.
Installing the unit too close to the ceiling can reduce air intake and impair performance. It can also make it more difficult to open the front panel and remove the filters.
In this project, the installation height allows for:
- good air intake above the unit;
- wider air distribution throughout the room;
- an unobstructed lower louver;
- reasonable access to the front panel;
- discreet integration into the wall;
- preserving usable space for furniture.
The high mounting position also promotes cooling. Cool air naturally descends, which helps distribute the temperature throughout the occupied area. In heating mode, the louver should be directed farther downward to prevent warm air from remaining near the ceiling.
The importance of airflow direction
A properly sized heat pump can still cause discomfort if its airflow is poorly directed.
We therefore assess the unit’s position based on:
- the location of the bed or sofa;
- the direction of movement in the room;
- doors and openings;
- the height of the furniture;
- the presence of a workstation;
- the distance between the appliance and the occupants.
In the photo, the unit is installed on a relatively unobstructed wall. This position allows the airflow to travel through the room without being immediately blocked by a bookcase or tall piece of furniture.
During commissioning, we check different louver positions and several fan speeds. The goal is to find a setting that promotes an even temperature without creating a direct draft.
An easily accessible wall-mounted control
To the right of the unit, a small wall-mounted control can be seen. Depending on the exact configuration, this type of device can provide convenient access to the main settings.
Its location was chosen at an accessible height and at a distance from the indoor unit. A control should not be placed in an area directly affected by airflow, sunlight, or another heat source, as this could distort the perceived temperature.
A good control location should notably avoid:
- the unit’s direct airflow;
- a very sunny window;
- an exterior door;
- a heat-producing appliance;
- a cold or damp wall;
- an inaccessible area.
The presence of this controller makes the system easier to use, particularly for a unit installed high up.
Choosing the capacities for the two zones
The photograph does not show the complete model number or the indoor unit’s exact capacity. Several Fujitsu AIRSTAGE wall-mounted units may have similar cabinets while offering different capacities.
We therefore never determine the BTU capacity solely from appearance.
To choose each indoor unit, we consider:
- area;
- ceiling height;
- room volume;
- number of windows;
- solar orientation;
- insulation level;
- floor;
- exterior walls;
- air infiltration;
- number of occupants;
- daily use;
- heat-producing appliances.
Selecting a heat pump should not be based on an approximate square-footage formula. Two rooms of the same size may have very different requirements if one has a large south-facing window and the other is in the center of the building.
Combinations permitted by Fujitsu
The Fujitsu AIRSTAGE Aquila series is available with several outdoor unit capacities, including 18,000, 24,000, 36,000, and 45,000 BTU/h. Depending on the model, an outdoor unit can power two to five indoor units.
For an 18,000 BTU/h outdoor unit designed for a dual-zone configuration, the Fujitsu tables list the following combinations, among others:
- 7,000 + 7,000 BTU/h;
- 7,000 + 9,000 BTU/h;
- 7,000 + 12,000 BTU/h;
- 7,000 + 15,000 BTU/h;
- 9,000 + 9,000 BTU/h;
- 9,000 + 12,000 BTU/h;
- 9,000 + 15,000 BTU/h;
- 12,000 + 12,000 BTU/h.
These data are used to verify compatibility between the units, but they do not replace a thermal load analysis.
Fujitsu also specifies that its combination tables are not intended to be used on their own to select the system capacity. The manufacturer recommends using its Design Simulator software to select AIRSTAGE H series equipment.
Why the total capacity of the indoor units can exceed the outdoor unit’s capacity
In some multi-zone systems, the sum of the indoor units’ nominal capacities may be greater than that of the outdoor unit.
For example, an 18,000 BTU/h outdoor unit can be connected to two indoor units totaling 21,000, 22,000, or 24,000 BTU/h, depending on the permitted combinations.
This possibility is explained by the fact that the two zones do not always require their full capacity at the same time.
An open area may have greater demands in the afternoon, while a bedroom becomes the priority at night. In this context, some oversizing may be permitted.
However, it is important to understand that this configuration does not create additional capacity. Fujitsu clearly states that exceeding 100% in a combination does not increase the system’s heating or cooling capacity.
When both zones simultaneously call for maximum output, the available capacity is divided between them.
A multi-zone system with a shared mode
Each indoor unit can be controlled separately, but the two zones generally share the same main mode.
The system can:
- heat both zones;
- cool both zones;
- operate only one unit;
- maintain different temperatures;
- use different fan speeds.
However, it cannot actively heat one zone while the other is simultaneously operating in cooling mode.
Fujitsu documentation specifies that the system provides heating and cooling, but not both at the same time.
This feature is important to explain, especially during the transition periods in spring and fall. One room may become warm in the sun while another remains cooler. In this case, occupants must choose a consistent shared mode or temporarily use another heat source in a specific zone.
A system designed to provide consistent comfort throughout Quebec’s seasons
Heating down to -26 °C for cold-climate models
In Saint-Constant, as elsewhere on the South Shore of Montreal, winter heating is an essential criterion when choosing a heat pump.
Fujitsu documentation indicates that the Aquila CTEB cold-climate models can operate in heating mode down to -26 °C. It also states that they can operate in cooling mode up to 50 °C.
However, it is important to distinguish the minimum operating temperature from the capacity actually available at that temperature. Like all heat pumps, the system’s performance varies according to outdoor conditions.
To assess the role of the heat pump during the winter, we consider:
- the capacity available at low temperatures;
- the heat loss of each zone;
- window quality;
- insulation;
- airtightness;
- the presence of supplemental heating;
- the requested temperature;
- exposure to wind.
A low-temperature heat pump can significantly reduce the use of electric baseboard heaters or another existing heating system, but it must be selected based on the actual building.
Variable-speed technology
The Fujitsu system’s compressor uses inverter technology. This allows it to adjust its speed according to the demand from both zones.
When temperatures are far from the setpoints, the system can increase its output. As the rooms approach the desired temperature, it can reduce its operation rather than shut down completely.
This modulation helps to:
- maintain a more stable temperature;
- reduce frequent start-ups;
- improve acoustic comfort;
- adapt consumption to the load;
- limit sudden fluctuations;
- respond more precisely to the needs of both zones.
The Fujitsu documentation also mentions a blue-fin heat exchanger designed to improve corrosion resistance, as well as several built-in protections for the circuits, fan motor, and compressor.
The refrigerant line routing
Each indoor unit in a dual-zone system has its own circuit to the outdoor unit.
This circuit generally includes:
- a liquid line;
- a gas line;
- insulation;
- a communication cable;
- a condensate drain.
In the photo, no significant line-set cover route is visible around the unit. This integration suggests a discreet passage to the side or rear of the wall, depending on the property’s configuration.
When the building allows it, we favor a short, orderly route. This reduces the visual impact and limits the number of changes in direction.
Refrigerant connections must be made precisely. A slow leak can cause:
- reduced capacity;
- extended cycles;
- ice formation;
- increased energy consumption;
- poor heating;
- error codes;
- potential damage to the compressor.
We therefore perform leak tests and pull a vacuum before commissioning.
Condensate drainage
In air conditioning, the indoor unit removes moisture from the air. This water must be discharged through a drain.
When gravity drainage is possible, we aim to maintain a continuous slope. A proper installation must avoid upward bends, crushed sections, and improperly secured connections.
A drainage problem can cause:
- a leak on the wall;
- odors;
- a gurgling noise;
- an overflowing drain pan;
- a safety shutdown;
- damage to interior finishes.
In a room with light-colored walls like the one in the photo, a leak would quickly become visible. A complete drain inspection is therefore an integral part of commissioning.
Validation steps before handing the system over to the customer
A dual-zone heat pump installation is not complete when the units are merely mounted on the wall.
We check in particular:
- the strength of the supports;
- the level of the indoor units;
- the tightness of the connections;
- the quality of the vacuum;
- the operation of each zone;
- communication between the units;
- drainage;
- the movement of the louvers;
- the response of the controls;
- the absence of vibration or unusual noise.
We then explain to the owner how the system works in general, the limitations of multi-zone mode, and basic maintenance tasks.
Mistakes to avoid in a similar installation
Install the unit too close to the ceiling
Air must enter freely through the top. Insufficient clearance can reduce airflow.
Position the unit without considering the furniture
A sofa, wardrobe, or bed may receive the airflow directly or block its distribution.
Choose capacity based solely on floor area
Glazing, insulation, exposure, and floor level strongly influence requirements.
Confusing indoor capacity with outdoor capacity
A higher indoor reading does not mean that the compressor produces more.
Forgetting access to the filters
The front panel must be easy to open, and the filters must remain accessible.
Placing the wall control in the airflow
The temperature reading may be affected if the control receives hot or cold air directly.
Maintaining the Fujitsu indoor unit
The visible unit is installed at a height. The owner must therefore provide safe access for cleaning the filters.
Routine maintenance includes:
- regular filter cleaning;
- checking the airflow;
- monitoring unusual noises;
- checking for any signs of water;
- clearance above the unit;
- gentle cabinet cleaning.
Professional HVAC maintenance goes further by cleaning:
- the heat exchanger;
- the tangential fan;
- the condensate pan;
- the drain;
- the louvers;
- the internal surfaces.
A dirty fan can reduce airflow even when the filters appear clean. The system may then seem less efficient even though its cooling capacity is still available.
Eligibility for financial assistance
Eligibility for a subsidy cannot be confirmed solely from the photo or the Aquila XLTH name.
Verification generally requires:
- the complete model of the outdoor unit;
- the models of both indoor units;
- the AHRI number of the combination;
- the recognized capacity at the required temperature;
- the installation date;
- the detailed invoice;
- the criteria specific to the building;
- the rules of the program in effect.
Since the nameplate is not legible in the photo, no precise amount can be attributed to this installation based solely on the image.
A project adapted to the property's actual needs
This installation in Saint-Constant demonstrates that a multi-zone heat pump can integrate discreetly into a residential interior while providing precise control of two areas.
The Fujitsu AIRSTAGE unit was installed high on a clear wall, with good air circulation, accessible controls, and discreet visual integration. The dual-zone configuration allows the owner to control two spaces separately without multiplying the number of outdoor units.
For us, the work involved coordinating the positioning, capacity, airflow, drainage, refrigerant lines, and future access for maintenance.
At AirGreen, we install wall-mounted heat pumps, multi-zone systems, and HVAC solutions in Montréal, Laval, Longueuil, the North Shore, and the South Shore. Each project is adapted to the architecture, thermal loads, and actual use of the rooms.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).