Project

Installation of a HITACHI airHome Multi dual-zone multizone heat pump in Auteuil, Laval

In Auteuil, we install a HITACHI airHome Multi multizone heat pump on a raised concrete base, with two independent zones, protected lines, and carefully integrated drainage.

By AirGreen Climatisation & Chauffage Admin17 min read
Installation of a HITACHI airHome Multi dual-zone multizone heat pump in Auteuil, Laval
Installation of a HITACHI airHome Multi dual-zone multizone heat pump in Auteuil, Laval
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

An installation on an existing concrete base adapted to the property’s actual constraints

In Auteuil, in northern Laval, we installed a HITACHI airHome Multi dual-zone multi-zone heat pump to cool and heat two distinct areas of the residence using a single outdoor unit. The project clearly illustrates a common reality in residential renovations: the best location is not always an open area where a new prefabricated slab can simply be placed.

On this property, a substantial concrete structure was already located against the side wall of the house. Rather than occupying another part of the yard or unnecessarily creating a second base, we studied the possibility of using this existing surface. Its height, apparent stability, and location near the path of the lines made it an interesting option, provided that the heat pump was installed correctly and the necessary clearances were maintained.

The result visible in the photo is a discreet and functional installation: the HITACHI airHome Multi outdoor unit rests on anti-vibration mounts, the refrigerant lines are directed into a vertical trim piece matching the home’s siding, and the drainage was routed downward in a controlled manner.

This configuration addressed several of the homeowner’s priorities:

  • serve two indoor zones without multiplying the number of outdoor units;
  • preserve the available lawn space;
  • minimize the visual impact of the lines;
  • keep the unit above the usual snow level;
  • facilitate access to the connections for future HVAC maintenance.

Why a dual-zone heat pump was suitable for this Auteuil home

A home can have very different heating and cooling needs from one floor to another or from one room to another. In Auteuil, as elsewhere in Laval, many residences have a finished basement, a ground floor exposed to the sun, and bedrooms upstairs. A single wall-mounted unit placed in a central area cannot always distribute air evenly throughout all these zones.

A dual-zone multi-zone heat pump allows two indoor units to be connected to the same outdoor unit. Each one can have:

  • its own setpoint;
  • its own fan speed;
  • programming adapted to the room’s use;
  • independent control;
  • a capacity selected according to the zone’s thermal load.

This makes it possible to maintain a comfortable temperature in a living area while applying a different setting in a bedroom, office, upper floor, or basement.

The HITACHI airHome Multi line is designed to support two to five indoor units, depending on the outdoor model. The two-connection version, RAM-G18N2HAA, offers a rated cooling capacity of 18,000 BTU/h and a rated heating capacity of 22,000 BTU/h. Its actual capacity is distributed among the active indoor units according to their demand and the selected combination.

The practical advantage of a single outdoor unit

Installing two single-zone systems would also have made it possible to control two rooms separately, but this approach would have required two condensers, more wiring, two disconnect devices, and more space around the house.

In this HVAC installation project in Auteuil, the multi-zone system offered several advantages:

  1. A more orderly exterior appearance
    Only one unit is visible along the building.
  2. Better use of the available space
    The existing concrete base could accommodate a single outdoor unit without compromising access or the yard.
  3. Two distinct comfort zones
    Occupants can adjust each indoor unit according to their habits.
  4. Centralized outdoor maintenance
    The compressor and the main outdoor components are housed in a single unit.
  5. Modulating capacity
    Inverter technology adjusts the compressor’s operation to the combined needs of the two zones.

However, it is important to clearly explain how a multi-zone system works: the indoor units can be adjusted separately, but they must operate in compatible modes. In summer, they can be used for cooling, dehumidification, or ventilation. In winter, they can operate in heating or ventilation mode. It is not possible to heat one room while the other is simultaneously in cooling mode with the same outdoor unit.

A raised concrete base: a constraint turned into an advantage

The large concrete base visible in the photo occupies a significant portion of the side yard. At first glance, it could have been considered an obstacle. Upon analysis, however, it offered several favourable characteristics.

Valuable protection against snow

In Laval’s climate, a heat pump installed too close to the ground can become surrounded by snow after a storm or after the yard has been cleared. Accumulations can obstruct the rear heat exchanger or reduce the space in front of the fan.

The elevated positioning of this unit helps keep it above:

  • ordinary snowbanks;
  • snow pushed up against the foundation;
  • dead leaves;
  • grass and vegetation;
  • water that could accumulate at ground level.

This clearance does not eliminate the need for the owner to clear the unit in winter, but it considerably reduces the risk of obstruction at ground level.

A solid and stable surface

A multizone heat pump must rest on a stable base. Any movement, settling, or misalignment can contribute to vibration and place undesirable strain on the connections.

The existing concrete surface provided a rigid support. Nevertheless, we added blocks and anti-vibration supports beneath the unit in order to:

  • to limit direct contact with the base;
  • to reduce vibration transmission;
  • to facilitate drainage beneath the unit;
  • to create a small space for inspection;
  • to protect the lower part of the cabinet from persistent moisture.

Leveling the unit remains essential. A poorly seated condenser can vibrate, produce more noise, or drain water from the defrost cycles less efficiently.

Visible drainage: a detail that plays an important role

On the side of the concrete base, we can see a transparent line descending toward the ground. In a multizone installation, each indoor unit produces condensation in cooling and dehumidification mode. This water must be drained by gravity or, when the configuration requires it, with a condensate pump.

Poorly designed drainage can lead to:

  • indoor leaks;
  • water accumulating inside the molding;
  • odors;
  • the buildup of deposits in the pipe;
  • damage to walls or ceilings;
  • water returning to the indoor unit.

In this project, the outdoor line was routed downward and secured against the structure to prevent it from remaining loose or being exposed to movement. The slope, outlet point, and stability of the pipe are just as important as its appearance.

It is also important to distinguish water from the indoor units from water produced by defrosting the outdoor unit. During winter heating, a heat pump extracts heat from the outdoor air. Frost may form on the heat exchanger and then melt during the defrost cycle. This water drains beneath the condenser and may freeze on the base.

The available clearance beneath the unit and the absence of an immediate obstruction help reduce the risk of an ice mass reaching the chassis. Nevertheless, the owner must monitor this area during extended periods of freezing temperatures.

A vertical molding selected to protect the connections

One of the most visually discreet elements in this Auteuil installation is the vertical molding that extends to the upper part of the wall. Its light color is close to that of the exterior cladding, reducing the visual impact of the lines.

This trim cover protects several essential components:

  • the copper refrigerant lines;
  • the insulation surrounding the gas line;
  • the communication cables;
  • certain drainage components, depending on the route;
  • the penetrations and transitions between the exterior and interior.

Without protection, the refrigerant insulation can be damaged by ultraviolet rays, birds, the weather, or maintenance work around the house. Damaged insulation can cause condensation and impair performance.

For the RAM-G18N2HAA dual-zone configuration, the manufacturer specifies two 1/4 in. liquid connections and two 3/8 in. gas connections on the outdoor unit side. The indicated minimum total length is 16 feet, while the maximum total length can reach 165 feet, subject to compliance with the system’s other technical limits.

This data does not mean that all installations should use the maximum permitted length. The more direct and well-planned the route, the easier it is to protect the piping, limit losses, and maintain an accessible installation.

Special attention to the vinyl siding

The exterior wall is covered with vinyl siding. This material must not directly support the weight of the trim cover or technical components. The fasteners must reach a solid structure behind the siding while avoiding crushing the panels.

When carrying out this type of installation, we must consider:

  • the expansion and contraction of the vinyl;
  • the watertightness of penetration points;
  • the location of the studs;
  • water management behind the siding;
  • the visual alignment of the trim cover;
  • the ability to access the lines later.

A trim cover installed at an angle or tightened excessively against the siding may deform with temperature changes. On this project, the vertical routing makes it possible to group the lines without creating a series of horizontal sections visible on the facade.

The day-to-day performance and features of the HITACHI airHome Multi

Efficiency of up to a SEER2 of 23.0

The airHome Multi range covers outdoor capacities from 18,000 to 42,000 BTU/h. Depending on the model and the type of connected indoor units, it can achieve a SEER2 of 23.0 and an EER2-5 of 7.85.

For the RAM-G18N2HAA two-zone ductless configuration, the manufacturer’s table indicates, among other things:

  • a rated cooling capacity of 18,000 BTU/h;
  • a rated heating capacity of 22,000 BTU/h;
  • a TRÉ2 of 12.5;
  • a TRÉS2 of 23.0;
  • a CPSC2 of 10.0 in Region 4 and 7.85 in Region 5;
  • a COP of 3.3 at 8 °C;
  • a maximum heating capacity of 14,300 BTU/h at -15 °C;
  • a maximum heating capacity of 9,700 BTU/h at -20 °C.

These figures demonstrate why sizing must be carried out carefully. A rated capacity stated at a moderate temperature is not the same as the capacity available during a very cold night in Laval.

We therefore assess the heat loss of each zone, insulation, windows, building orientation, and the presence of a supplementary heating system before confirming the combination of units.

Heating operation down to -20 °C

The manufacturer indicates a heating operating range from -20 °C to 24 °C for the outdoor units in this range. The cooling range extends from -10 °C to 46 °C.

This cold-weather operating capability is relevant for a residence in Auteuil. However, it does not mean that the heat pump will produce its full rated capacity at -20 °C. Performance and capacity gradually decrease as the outdoor temperature drops.

In a well-designed installation, we seek to maximize the efficient use of the heat pump while maintaining appropriate backup heating for periods when demand exceeds its available capacity.

Several indoor unit options

The airHome Multi platform can be combined with different indoor formats:

  • airHome 400, a wall-mounted unit focused on essential features;
  • airHome 650, a wall-mounted unit with additional smart features;
  • airHome Floor, a floor console;
  • airHome Mini Cassette, integrated into the ceiling;
  • airHome Ducted, concealed in a mechanical space.

Available indoor capacities generally range from 7,000 to 24,000 BTU/h, depending on the selected family. This flexibility makes it possible to adapt each zone to its architecture rather than imposing two identical units in very different rooms.

A sound level suitable for a residential area

The outdoor model with two connections is rated for a high sound level of 52 dB(A). Depending on the model, some wall-mounted indoor units can operate at 27 or 29 dB(A) at low speed, while floor consoles can go as low as 22 dB(A).

However, the outdoor unit’s placement affects acoustic comfort just as much as its specifications. A unit installed in a recess, against several reflective surfaces, or directly beneath a bedroom window may seem noisier.

On this project, the front of the fan faces an open space. The discharged air can therefore disperse without immediately hitting a wall located a few inches in front of the unit.

FrostWash and Mold Guard: useful features that do not replace cleaning

Some compatible indoor units use FrostWash technology. The coil is cooled to form a layer of frost, which then melts and carries away some of the contaminants accumulated on the heat exchanger.

The Mold Guard function continues internal ventilation for approximately 60 minutes after certain cooling or drying operations. It helps dry the internal components and limit conditions that promote odors and mold.

These features can help keep the inside of the appliance clean, but they do not replace:

  • periodic filter cleaning;
  • inspecting the drain;
  • professional cleaning of the tangential fan;
  • checking the heat exchanger;
  • complete HVAC maintenance when the appliance is dirty.

R32 refrigerant filtration and monitoring

Depending on the indoor model, the range may use a PM2.5 activated carbon filter or a ViroSense S filter. Some units also include an R32 refrigerant leak sensor, accompanied by a visual and audible alarm or an optional receiver kit.

The system uses the refrigerant R32. The installation must therefore be carried out using the appropriate tools, practices, and procedures. The quality of the flared connections, the leak test, evacuation, and commissioning are critical to the system’s reliability.

Smart control with airCloud Go

An optional Wi-Fi interface allows use of the airCloud Go app. The owner can then manage certain settings remotely, create schedules, and monitor the system’s operation.

For a dual-zone installation, this controller can be particularly practical when one unit is on another floor or in a less accessible room. Each zone can be adjusted according to its occupancy while respecting the system’s general mode.

Mistakes to avoid in a multi-zone installation in Laval

This project highlights several common mistakes that we aim to prevent.

Choosing the base simply because it already exists

An existing structure is not automatically suitable. Its stability, level, dimensions, and the clearances around the unit must be checked.

Block access to the connections

The technical side of the heat pump must remain accessible for testing, repairs, and maintenance. A trim piece or obstacle placed too close can unnecessarily complicate servicing.

Underestimating defrost water

An installation elevated on concrete can produce a significant sheet of ice in winter. Space must be maintained beneath the chassis, and buildup must be monitored.

Installing an indoor unit that is too powerful for a small room

An oversized unit can quickly reach the requested temperature without providing good dehumidification. Capacity selection must be based on the needs of each zone.

Assuming that two zones can operate in opposite modes

The controls are independent, but the outdoor unit remains shared. Occupants must understand this feature during commissioning.

Neglecting line protection

Insulation exposed to sunlight deteriorates. The exterior trim is not merely decorative: it protects an essential part of the refrigeration system.

An installation designed to remain accessible

The outdoor unit is positioned high enough to protect it from the ground, while remaining accessible without heavy specialized equipment. The service panels, electrical connections, and lines can be inspected from the base.

This accessibility is important. A highly aesthetic but unserviceable installation often leads to additional costs several years later. At AirGreen, we consider the following from the outset:

  • potential replacement of a component;
  • heat exchanger cleaning;
  • access to the valves;
  • wiring inspection;
  • drainage control;
  • the safe removal of the unit if necessary.

The final result of our installation in Auteuil

This multi-zone heat pump installation in Laval transforms an architectural constraint into a practical solution. The existing concrete base now serves as a stable, elevated support, while the vertical trim protects the lines and blends discreetly with the home’s light-colored siding.

The homeowner now benefits from two separately controlled comfort zones powered by a single HITACHI outdoor unit.

The main elements of the project include:

  • a HITACHI airHome Multi dual-zone heat pump;
  • an installation raised above the ground;
  • anti-vibration supports;
  • a protected vertical route for the lines;
  • drainage secured along the base;
  • a completely unobstructed ventilation facade;
  • a configuration adapted to the needs of two spaces;
  • an installation designed for Auteuil’s winter conditions.

This project reflects our approach to installations in Montréal, Laval, Longueuil, the North Shore, and the South Shore: observe the building, use the available space intelligently, and build an HVAC solution that remains logical long after our team has left.

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment