Project

Installing a SHARP BU dual-zone heat pump in Senneville, compared with the FUJITSU AIRSTAGE AQUILA XLTH

The SHARP BU job in Senneville (a 9,000 BTU head above a door) and the 24,000 BTU FUJITSU AIRSTAGE AQUILA XLTH: NEEP, extreme cold, cost.

By AirGreen Climatisation & Chauffage Admin14 min read
Installing a SHARP BU dual-zone heat pump in Senneville, compared with the FUJITSU AIRSTAGE AQUILA XLTH
Installing a SHARP BU dual-zone heat pump in Senneville, compared with the FUJITSU AIRSTAGE AQUILA XLTH
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

Comparison · 2-zone multi-zone · 24,000 BTU/h

SHARP BU and FUJITSU AIRSTAGE AQUILA XLTH: one head above a door, one in the living room

In Senneville, AirGreen installed a SHARP BU heat pump: a 24,000 BTU/h outdoor unit, a 9,000 BTU wall unit mounted above a door in the bedroom, and an 18,000 BTU one in the living room. Here is that job, then the 24,000 BTU/h two-zone FUJITSU AIRSTAGE AQUILA XLTH sold by AirGreen, published value by published value. This page’s angle: mounting a head in the narrow space between a door frame and the ceiling. No ranking.

Common nominal size: 24,000 BTU/hSame HSPF2 Region V: 9.0Both on R-32 (A2L)The job: 9,000 + 18,000 BTU of heads
SHARP installed in Senneville
SHARP BU dual-zone heat pump: two wall units and the AE-X3M24BU outdoor unit

SHARP BU dual-zone

Outdoor AE-X3M24BU · heads AY-XPC9BU + AY-XPC18BU
AHRI 213927543 · NEEP 507394

See the product page
FUJITSU AIRSTAGE two zones
FUJITSU AIRSTAGE AQUILA XLTH 2-zone heat pump: two wall units and the AOUH24KWAH3 outdoor unit

FUJITSU AIRSTAGE AQUILA XLTH 2-zone

Outdoor AOUH24KWAH3 · 9,000 head: ASUH09KPAS
AHRI 215447693 · NEEP 455167

See the product page

Both AHRI certificates cover a multi-zone system with non-ducted indoor units; certified values belong to the whole system. NEEP certifies the FUJITSU AIRSTAGE at 22,000 BTU/h cooling at 35 °C; the page compares at the common nominal size of 24,000 BTU/h.

Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for a Senneville house whose heat loss reaches 24,000 BTU/h, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated the same way, with the same method as on all our comparison pages, at the common size of 24,000 BTU/h; only their certified efficiencies change. Their HSPF2 Region V is identical (9.0): winter costs the same with either one, and the small difference comes from summer. Degree-days are Montréal’s, the nearest reference station published by Natural Resources Canada. Electric baseboards serve as the point of reference.

How this amount is calculated
  1. Heat needed over the winter. A house whose heat loss reaches 24,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 24,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: this is a maximum, since a variable-speed unit slows down when the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The Senneville job

Above the door: the room between the frame and the ceiling

In the bedroom, the only free wall was above the door. The 9,000 BTU head went there; the 18,000 BTU one is in the living room. The “9 / 18” combination is in SHARP’s table for the AE-X3M24BU. Both 9,000 BTU heads are drawn to scale from their published dimensions. Set the ceiling height, the top of the frame and its width.

Diagram to scale, front view, same scale for both heads. SHARP AY-XPC9BU: 34 39/64 × 11 3/8 in (2025 brochure). FUJITSU AIRSTAGE ASUH09KPAS: 32 13/16 × 10 5/8 in (FG2057B brochure). The ceiling and the frame are values you choose.

The minimum clearance below the ceiling and on the sides is in each manufacturer’s installation manual; it is not reproduced here. The condensate drain line also needs its slope. This figure does not replace a visit.

The SHARP heads of the job

AY-XPC9BU, above the door: 8,500 BTU/h cooling, 10,000 heating, 23 to 43 dB(A). AY-XPC18BU, living room: 18,000 and 19,500 BTU/h, 25 to 49 dB(A), 41 27/64 in wide. Per-head capacities published in the SHARP 2025 brochure; certified values remain the system’s.

The FUJITSU AIRSTAGE 9,000 head

ASUH09KPAS: 10 5/8 × 32 13/16 × 8 3/4 in, 21 lb; 21 to 40 dB(A) cooling and 22 to 42 dB(A) heating depending on speed (FG2057B brochure). The brochure gives a connectable indoor capacity of 14,000 to 31,000 BTU/h on the AOUH24KWAH3; 9,000 + 18,000 = 27,000 falls within that range, and the combination is confirmed in the manufacturer’s table.

Extreme cold

Below −15 °C, what each manufacturer publishes

At −15 °C, both certificates give a value at the same temperature. Further down, NEEP publishes each system’s coldest point: −26.1 °C for the FUJITSU AIRSTAGE, −27.2 °C for the SHARP. The SHARP brochure also prints a maximum capacity at −20 and −25 °C; between the FUJITSU AIRSTAGE’s published points, the page shows the bracket, with no calculation.

Documented features

What each brochure names, card by card

Only what the documents consulted name: the SHARP 2025 brochure, the FUJITSU AIRSTAGE FG2057B brochure (AQUILA XLTH pages) and the NEEP records.

Cut-off in extreme cold

SHARP Heating range advertised down to −27 °C (brochure).

FUJITSU AIRSTAGE Heating down to −26 °C and no shut-off device, per the FG2057B brochure, p. 18.

Base pan heater

SHARP Not stated in the brochure; the NEEP field is blank.

FUJITSU AIRSTAGE Yes, 150 W per NEEP; named in the brochure.

Connectable indoor capacity

SHARP 2 or 3 heads, per the combination table (including 9 / 18).

FUJITSU AIRSTAGE 2 to 3 units, 14,000 to 31,000 BTU/h in total (brochure).

Wi-Fi and app

SHARP Wi-Fi built into all units, per the SHARP 2025 brochure.

FUJITSU AIRSTAGE Not recorded in the brochure pages consulted.

Auto restart

SHARP Yes, after a power outage (brochure).

FUJITSU AIRSTAGE Not recorded in the pages consulted.

Indoor unit cleaning

SHARP Plasmacluster cleaning function, 40-minute internal cycle (brochure).

FUJITSU AIRSTAGE Not recorded in the pages consulted.

“Not recorded” means the pages consulted do not mention it, not that the feature is absent.

Sound

In the bedroom and outside: the published sound levels

dB(A)

How to read these numbers. The lower the number, the quieter the unit. The first two rows show the 9,000 BTU heads, the one above the bedroom door; each dot is a published speed. The last two show the outdoor units.

Why this is not a ranking. Different method, not comparable: each manufacturer measures at its own distance and in its own conditions, and SHARP publishes only the lowest and highest speed of its head.

Values published by each manufacturer, by its own method: they read side by side, without ranking.

Installation

Piping, height difference and power supply, per the brochures

ItemSHARP BUFUJITSU AIRSTAGE AQUILA XLTH
Maximum piping length230 ft (70 m) in totalSHARP 2025 brochure; length per head not stated230 ft in total; 16 to 82 ft per unit; 33 ft minimum in totalFG2057B brochure, p. 19
Precharged lengthNot stated in the brochure98 ft in totalFG2057B brochure, p. 19
Maximum height difference33 ft (10 m)SHARP 2025 brochure49 ft outdoor–indoor, 33 ft between indoor unitsFG2057B brochure, p. 19
Liquid – gas diameters1/4 – 3/8 in, ports A, B, CSHARP 2025 brochure1/4 – 3/8 in (two ports) and 1/4 – 1/2 in (one port)FG2057B brochure, p. 19
Connectable indoor units2 or 3SHARP 2025 brochure, combination table2 to 3 (14,000 to 31,000 BTU/h)FG2057B brochure, p. 19
Outdoor unit W × H × D, weight33 15/32 × 27 15/16 × 13 in, 115 lbSHARP 2025 brochure32 5/16 × 34 13/16 × 12 3/8 in, 119 lbFG2057B brochure, p. 19
Electrical protection208-230 V; max. fuse 25 ASHARP 2025 brochure25 A breaker; max. current 19.2 AFG2057B brochure, p. 19
Advertised heating / cooling range−27 to 24 °C / −10 to 46 °CSHARP 2025 brochure−26 to 24 °C / −10 to 50 °CFG2057B brochure, p. 19
Base pan heaterNot stated (brochure; NEEP field blank)Yes, 150 WNEEP 455167
RefrigerantR-32 · GWP 675 (IPCC AR4) · class A2LR-32 · GWP 675 (IPCC AR4) · class A2L

The FUJITSU AIRSTAGE brochure also prints an MCA of 13.6 A, lower than the 19.2 A maximum current: that value is not used here; the installation manual governs. Clearances around the units are confirmed in the manuals before the work.

Questions

What people ask before mounting a head above a door

Why the FUJITSU AIRSTAGE AQUILA XLTH next to the SHARP BU?

Both are 24,000 BTU/h multi-zone systems on R-32, certified with non-ducted wall units, ENERGY STAR and cold climate per NEEP, and sold by AirGreen. Their HSPF2 Region V is the same (9.0). The page makes no ranking.

Is above a door a good spot for a head?

It is often the only free wall in a bedroom. There must be enough height between the frame and the ceiling for the head and its clearances, a route for the lines and a slope for the drain. The “Above the door” section shows the room left for your ceiling; the minimum clearance is in each manufacturer’s manual.

9,000 + 18,000 makes 27,000 on a 24,000 unit: is that planned?

At SHARP, the brochure lists “9 / 18” among the AE-X3M24BU’s combinations. At FUJITSU AIRSTAGE, the brochure gives 14,000 to 31,000 BTU/h of connectable indoor capacity on the AOUH24KWAH3. The heads do not all ask for full output at the same time; the exact combination is confirmed in the manufacturer’s table before the quote.

Why does winter cost the same with both?

The heating calculation uses the certificate’s HSPF2 Region V, and both systems show 9.0. With the same house and the same number of hours, the result is identical. The small yearly difference comes from summer: SEER2 24.0 for the SHARP BU, 23.5 for the FUJITSU AIRSTAGE.

Are these systems eligible for incentive programs?

Eligibility is checked with the AHRI number in the program’s current official list (for example Hydro-Québec’s LogisVert), which can change. The numbers are 213927543 for the SHARP BU and 215447693 for the FUJITSU AIRSTAGE AQUILA XLTH. This page announces no amount.

What about the warranty?

The page does not compare warranties. Each manufacturer’s warranty documents come with the quote.

Certified sheet

The AHRI certificate, value by value

Value (NEEP, read Nov. 17, 2026)SHARP BUFUJITSU AIRSTAGE AQUILA XLTH
Seasonal efficiency
SEER224,023,5
EER214,013,5
HSPF2 Region IV11,511,5
HSPF2 Region V9,09,0
Rated capacity at 35 °C (cooling)24 000 BTU/h22 000 BTU/h
Heating, min. / rated / max.
Capacity min. / rated / max. at 8.3 °C8 800 / 26 000 / 30 000 BTU/h6 800 / 25 000 / 31 000 BTU/h
COP min. / rated / max. at 8.3 °C4,69 / 4,35 / 4,195,54 / 4,70 / 4,41
Capacity min. / rated / max. at −8.3 °C7 600 / 25 000 / 25 000 BTU/h4 700 / 16 200 / 26 800 BTU/h
COP min. / rated / max. at −8.3 °C2,93 / 2,53 / 2,533,83 / 3,34 / 2,53
Capacity min. / rated / max. at −15 °C8 400 / 21 200 / 21 200 BTU/h3 900 / 25 200 / 25 200 BTU/h
COP min. / rated / max. at −15 °C2,46 / 2,30 / 2,303,17 / 2,10 / 2,10
Coldest published point (different temperatures)
Test temperature−27,2 °C (−17 °F)−26,1 °C (−15 °F)
Capacity min. / max.5 100 / 14 600 BTU/h2 500 / 14 000 BTU/h
COP at min. / at max.1,74 / 1,842,04 / 1,68
Certification
ENERGY STARYesYes
ENERGY STAR cold climateYesYes
AHRI certificate · NEEP record213927543 · 507394215447693 · 455167
RefrigerantR-32R-32

“higher” marks the higher value of the same measure under the same conditions. It is not a recommendation. The HSPF2 values are identical: no mark.

Both are on AirGreen’s site.

An estimate visit lets you measure the wall above a door, choose the heads and the line route, room by room.

Sources

Documents consulted

NEEP, record 507394 (SHARP AE-X3M24BU)AHRI 213927543, “Multi Zone series”; consulted Nov. 17, 2026
NEEP, record 455167 (FUJITSU AIRSTAGE AOUH24KWAH3)AHRI 215447693, “AIRSTAGE H-series”; consulted Nov. 17, 2026
SHARP 2025 brochure, “BU multi-zone series”French version, p. 13 (undated, no number); consulted Nov. 17, 2026
FUJITSU AIRSTAGE brochure FG2057BRevision 8/2025, French version, pp. 18 and 19 (AQUILA XLTH); recorded Nov. 16, 2026
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, art. 2.5
NRCan, HOT2000 climate mapMontréal Intl station: 4,167 degree-days, −23.1 °C
In figures
The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
The unit

What the unit delivers when it is cold

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp BU 24 0002 Zones (Dual Zone)25,00021,200−27 °C: 14,6002.324.011.5$3,000
Sharp BU 24 0003 Zones (Triple Zone)25,00021,200−27 °C: 14,6002.324.011.5$3,000
Most EfficientENERGY STAR

Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.

8,800BTU/h at low speed

Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.

−27 °CColdest certified point

NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.

675R-32 GWP

Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment