SHARP BU dual-zone
Outdoor AE-X3M24BU · heads AY-XPC9BU + AY-XPC18BU
AHRI 213927543 · NEEP 507394
The SHARP BU job in Sainte-Julie (9,000 and 18,000 BTU heads) and the 24,000 BTU SAMSUNG FJM Premium: fence to scale, NEEP, extreme cold, cost.

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp BU 24 0002 Zones (Dual Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
| Sharp BU 24 0003 Zones (Triple Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
In Sainte-Julie, AirGreen installed a SHARP BU heat pump: a 24,000 BTU/h outdoor unit, a 9,000 BTU wall unit in the main bedroom and an 18,000 BTU one in the living room. Here is that job, then the 24,000 BTU/h two-zone SAMSUNG FJM Premium sold by AirGreen, published value by published value. In the suburbs, the outdoor unit can be seen and heard from the yard next door: that is this page’s angle. No ranking.

Outdoor AE-X3M24BU · heads AY-XPC9BU + AY-XPC18BU
AHRI 213927543 · NEEP 507394

Outdoor AJ024DXS4CG/AA · wall heads AJ009DNADCG and AJ018DNADCG
AHRI 216372794 · NEEP 417117
Both AHRI certificates cover a multi-zone system with non-ducted indoor units; certified values belong to the whole system. NEEP certifies the SAMSUNG at 25,000 BTU/h cooling at 35 °C; the page compares at the common nominal size of 24,000 BTU/h.
AirGreen estimate for a Sainte-Julie house whose heat loss reaches 24,000 BTU/h, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated the same way, with the same method as on all our comparison pages, at the common size of 24,000 BTU/h; only their certified efficiencies change. Degree-days are Montréal’s, the nearest reference station published by Natural Resources Canada. Electric baseboards serve as the point of reference.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
The owner wanted two zones of different sizes: 9,000 BTU in the main bedroom, 18,000 BTU in the living room, both connected to a single outdoor unit. The “9 / 18” combination is in SHARP’s table for the AE-X3M24BU. Outside, the suburban question is simple: will the unit stick out above the fence? Both outdoor units are drawn to scale from their published dimensions. Set the fence height and the stand height.
Diagram to scale, front view, same scale for both units. SHARP: 33 15/32 × 27 15/16 in (2025 brochure). SAMSUNG: 37 × 47 5/8 in (AJ024DXS4CG/AA submittal sheet). The fence and the stand are values you choose.
The allowed fence height and the location of an outdoor unit depend on the municipal by-law; the stand depends on the installation and the snow. This figure does not replace a visit.
AY-XPC9BU, bedroom: 8,500 BTU/h cooling, 10,000 heating, 23 to 43 dB(A), 34 39/64 in wide. AY-XPC18BU, living room: 18,000 and 19,500 BTU/h, 25 to 49 dB(A), 41 27/64 in wide. Per-head capacities published in the SHARP 2025 brochure; certified values remain the system’s.
AirGreen’s product page for the FJM Premium set lists the AJ009DNADCG and AJ018DNADCG wall units. Their Samsung spec sheet was not consulted for this page: their dimensions and sound level are not compared here. The 9 / 18 combination is checked in Samsung’s table before the quote.
At −15 °C, both certificates give a value at the same temperature. NEEP also publishes a point at −25 °C for the SAMSUNG, the heating limit stated on its sheet. For the SHARP, the brochure prints a maximum capacity at −20, −25 and −27 °C, and NEEP publishes its coldest point at −27.2 °C.
Only what the documents consulted name. For the SAMSUNG, the source is the outdoor unit’s submittal sheet and the NEEP record; the wall heads’ features are not in them.
SHARP Not stated in the brochure; the NEEP field is blank.
SAMSUNG 150 W, switched on at −8 °C in heating per NEEP; standard per the submittal sheet.
SHARP Wi-Fi built into all units, per the SHARP 2025 brochure.
SAMSUNG Not named on the outdoor unit sheet; AirGreen’s product page lists it as included.
SHARP 2 or 3, per the combination table.
SAMSUNG Up to 4, per the submittal sheet.
SHARP Yes, after a power outage (brochure).
SAMSUNG Not named in the documents consulted.
SHARP Plasmacluster cleaning function, 40-minute internal cycle (brochure).
SAMSUNG Not named in the documents consulted.
SHARP −27 to 24 °C (brochure).
SAMSUNG −25 to 24 °C (−13 to 75 °F, submittal sheet).
“Not named” means the document consulted does not mention it, not that the feature is absent.
How to read these numbers. The lower the number, the quieter the unit. Each dot is a value published by the manufacturer.
Why this is not a ranking. Different method, not comparable: each manufacturer measures at its own distance and in its own conditions, and a fence, a wall or a hedge changes what is heard next door. Indoors, SHARP publishes 23 to 43 dB(A) for the 9,000 head and 25 to 49 dB(A) for the 18,000 one.
Values published by each manufacturer, by its own method: they read side by side, without ranking.
| Item | SHARP BU | SAMSUNG FJM Premium |
|---|---|---|
| Maximum piping length | 230 ft (70 m) in totalSHARP 2025 brochure; length per head not stated | 230 ft in total, 82 ft per headAJ024DXS4CG/AA submittal sheet (02142025A) |
| Maximum height difference | 33 ft (10 m)SHARP 2025 brochure | 49 ft outdoor–indoor, 25 ft between headsSubmittal sheet |
| Connectable indoor units | 2 or 3SHARP 2025 brochure, combination table | Up to 4Submittal sheet |
| Outdoor unit W × H × D, weight | 33 15/32 × 27 15/16 × 13 in, 115 lbSHARP 2025 brochure | 37 × 47 5/8 × 13 in, 194 lbSubmittal sheet |
| Electrical protection | 208-230 V; max. fuse 25 ASHARP 2025 brochure | MCA 35.9 A; breaker 40 ASubmittal sheet |
| Advertised heating / cooling range | −27 to 24 °C / −10 to 46 °CSHARP 2025 brochure | −25 to 24 °C / −10 to 46 °CSubmittal sheet (−13 to 75 °F / 14 to 115 °F) |
| Base pan heater | Not stated (brochure; NEEP field blank) | Yes, standard, 150 WNEEP 417117; submittal sheet |
| Refrigerant | R-32 · GWP 675 (IPCC AR4) · class A2L | R-32 · GWP 675 (IPCC AR4) · class A2L |
The SAMSUNG’s connection diameters, precharged length and clearances were not recorded for this page; the SHARP’s are not all published in the brochure. They are confirmed in the installation manual before the work.
Both are 24,000 BTU/h multi-zone systems on R-32, certified with non-ducted wall units, ENERGY STAR and cold climate per NEEP, and sold by AirGreen. Both accept two heads of different sizes on one outdoor unit. The page names no winner.
At SHARP, yes: the brochure lists “9 / 18” among the AE-X3M24BU’s dual-zone combinations. The heads do not all ask for full output at the same time, and the compressor shares its capacity between them. For the SAMSUNG, the exact combination is checked in the manufacturer’s table before the quote.
The published values are 49 and 50 dB(A) for the SHARP (brochure) and 51 and 52 dB(A) for the SAMSUNG (submittal sheet), but each manufacturer measures its own way: they do not rank. The unit’s height also matters: the SAMSUNG is 47 5/8 in tall, the SHARP 27 15/16 in. The “Behind the fence” section shows what that gives with your fence.
At −15 °C, NEEP certifies 21,200 BTU/h for the SHARP BU and 25,000 BTU/h for the SAMSUNG, at full output. At −25 °C, NEEP publishes 18,000 BTU/h for the SAMSUNG; for the SHARP, the brochure prints 15,700 BTU/h at that temperature, outside the certificate. The two values come from different sources: the Extreme cold section shows them with their source.
Eligibility is checked with the AHRI number in the program’s current official list (for example Hydro-Québec’s LogisVert), which can change. The numbers are 213927543 for the SHARP BU and 216372794 for the SAMSUNG FJM Premium. This page announces no amount.
The page does not compare warranties. Each manufacturer’s warranty documents come with the quote.
| Value (NEEP, read Nov. 17, 2026) | SHARP BU | SAMSUNG FJM Premium |
|---|---|---|
| Seasonal efficiency | ||
| SEER2 | 24,0 | 23,0 |
| EER2 | 14,0 | 14,55 |
| HSPF2 Region IV | 11,5 | 10,4 |
| HSPF2 Region V | 9,0 | 7,1 |
| Rated capacity at 35 °C (cooling) | 24 000 BTU/h | 25 000 BTU/h |
| Heating, min. / rated / max. | ||
| Capacity min. / rated / max. at 8.3 °C | 8 800 / 26 000 / 30 000 BTU/h | 7 600 / 25 000 / 42 000 BTU/h |
| COP min. / rated / max. at 8.3 °C | 4,69 / 4,35 / 4,19 | 4,95 / 4,70 / 3,58 |
| Capacity min. / rated / max. at −8.3 °C | 7 600 / 25 000 / 25 000 BTU/h | 13 500 / 15 200 / 25 000 BTU/h |
| COP min. / rated / max. at −8.3 °C | 2,93 / 2,53 / 2,53 | 2,91 / 2,89 / 2,12 |
| Capacity min. / rated / max. at −15 °C | 8 400 / 21 200 / 21 200 BTU/h | 13 500 / 25 000 / 25 000 BTU/h |
| COP min. / rated / max. at −15 °C | 2,46 / 2,30 / 2,30 | 2,20 / 1,85 / 1,85 |
| Coldest published point (different temperatures) | ||
| Test temperature | −27,2 °C (−17 °F) | −25 °C (−13 °F) |
| Capacity min. / max. | 5 100 / 14 600 BTU/h | 11 000 / 18 000 BTU/h |
| COP at min. / at max. | 1,74 / 1,84 | 1,65 / 1,61 |
| Certification | ||
| ENERGY STAR | Yes | Yes |
| ENERGY STAR cold climate | Yes | Yes |
| AHRI certificate · NEEP record | 213927543 · 507394 | 216372794 · 417117 |
| Refrigerant | R-32 | R-32 |
“higher” marks the higher value of the same measure under the same conditions. It is not a recommendation. At −8.3 °C, the SAMSUNG’s certified rated value (15,200 BTU/h) is lower than its maximum (25,000 BTU/h): that is what NEEP publishes.
An estimate visit lets you choose the heads, the outdoor unit location and the line route, room by room.
Data verified on November 17, 2026. Certified values come from the AHRI certificates published by NEEP; the others come from the manufacturers’ documents, named under each value. When two sources differ, the page follows the certificate.
The SHARP and SAMSUNG marks belong to their owners. Logos and images identify the products. AirGreen is a dealer; this article is not produced, sponsored or approved by the manufacturers. Photos: AirGreen and manufacturers, for identification.
Does a value look wrong? Write to us at sales@airgreen.ca.
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Six simple habits that keep the unit going. Your list stays on this device.
Three habits per season for this unit. They take a few minutes and prevent many calls.
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
No question matches. Write to us: we answer.
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).