SHARP ZU1 wall heat pump installation in Montréal-Nord: the job, and how it compares with the SHARP CU (18,000 BTU)
An 18,000 BTU SHARP ZU1 installed under a balcony in Montréal-Nord, then compared figure by figure with the same-size SHARP CU: AHRI certificates, extreme cold, sound, installation and estimated cost.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
SHARP ZU1 and SHARP CU: same cabinet, two generations, figure by figure
AirGreen installed an 18,000 BTU SHARP ZU1 in a Montréal-Nord house. SHARP also offers the CU series in the same size, and AirGreen offers both. Their certified seasonal ratings and their dimensions are identical; their figures part ways when it gets very cold. Here is what the AHRI certificates and SHARP documents say, without a ranking.


SHARP CU 18,000
AY-XPC18CU / AE-X18CU · AHRI 217508915See the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. Here the ZU1 and the CU have the same HSPF2 Region V (9.0) and the same SEER2 (24.0): the calculation gives the same amount for both.
How this amount is calculated
- Heat to deliver over the winter. A zone whose heat loss reaches 18,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 18,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
- Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.
AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
An 18,000 BTU unit mounted under a balcony in Montréal-Nord
The owner wanted to heat and cool the house with a single wall unit, keeping heat through Québec winters, with an 18,000 BTU capacity and Wi-Fi control. The choice was a SHARP ZU1.
The photos show the outdoor unit on a wall bracket against the foundation, under a wooden balcony, next to a basement window. The refrigerant lines run in a white raceway along the wall. The 41.4-inch-wide indoor unit is connected with 1/4 and 3/8-inch lines, at 208-230 V.
What this job teaches someone deciding today: the SHARP CU series has exactly the same outdoor cabinet (33.5 × 27.9 × 13 in, 95 lb). The spot under this balcony would therefore suit either one in terms of size; the difference lies elsewhere, further down this page.


Under your balcony: the room the outdoor cabinet takes
Scale diagram, front view. Same cabinet for the ZU1 and the CU: 33.5 in wide, 27.9 in tall. Set your own measurements.
The minimum clearances required by SHARP are not legible in the documents consulted: this calculation does not say whether a spot complies, only how much room is left.
Line by line: what is identical and what differs
Twenty measures taken from both certificates and both SHARP documents. Hide the identical lines to keep only the differences; the bars use the same scale for both units.
13 identical lines out of 20; 7 differences, all related to heating except one medium-speed sound value.
NEEP’s turndown ratio is the maximum capacity at −15 °C divided by the minimum capacity at 8.3 °C (18,000 ÷ 5,500 and 19,000 ÷ 5,500). “Differs” does not mean better or worse: it is a gap between two published figures.
Below −15 °C, every published value and its source
The certificates give one point at −15 °C and one colder point: −27.2 °C for the ZU1, −30 °C for the CU. In between, SHARP publishes maximum capacities at −20 and −25 °C in the ZU brochure and in the CU submittal.
The ZU brochure prints model AY-XPC18ZU / AE-X18ZU; its values are identical to the ZU1 certificate at −8.3, −15 and −27 °C. Manufacturer values are measured with 21.1 °C indoors (CU submittal) and are not part of the certificate.
What each document names
A feature missing from a document is not necessarily missing from the unit: it is simply not named there.
SHARP describes a system that keeps the bottom of the outdoor unit clear of ice by reusing heat from the circuit, without a separate heating element.
The Montréal-Nord owner wanted this remote control.
Automatic vertical louvers, manual horizontal louvers for both according to the documents.
SHARP technology name only; this page attributes no effect to it.
After a power outage, the unit resumes its settings.
Indoor unit sound, speed by speed
Cooling values, where the only gap is; in heating, all five values are identical (49, 47, 41, 31 and 25 dB(A)). Outdoors: 52 dB(A) for both.
How to read these figures · dB(A) of sound pressure: the lower the number, the quieter. Each dot is a published fan speed.
Why this is not a ranking · Neither document states the measuring distance or room; a 2 dB(A) gap at a single speed should be read with that caveat.
Measurements taken by each manufacturer with its own method; here, the same manufacturer for both.
The published limits for installing either one
| Item | SHARP ZU1 18,000 | SHARP CU 18,000 |
|---|---|---|
| Maximum piping length | 66 ft (20 m)ZU/ZHU brochure (RBL), AY-XPC18ZU column | 66 ft (20 m); minimum 10 ftSHARP submittal, Jan. 2026 |
| Pre-charged length | Not published by the manufacturer in the ZU brochure consulted | 25 ft (7.6 m)SHARP submittal, Jan. 2026 |
| Maximum height difference | 33 ft (10 m)ZU/ZHU brochure (RBL), AY-XPC18ZU column | 33 ft (10 m)SHARP submittal, Jan. 2026 |
| Liquid – gas diameters | 1/4 – 3/8 inZU/ZHU brochure (RBL), AY-XPC18ZU column | 1/4 – 3/8 inSHARP submittal, Jan. 2026 |
| Additional refrigerant charge | Not published by the manufacturer in the ZU brochure consulted | 0.16 oz/ft beyond 25 ft; R-32, 49.0 oz factory chargeSHARP submittal, Jan. 2026 |
| Outdoor unit W × H × D, weight | 33.5 × 27.9 × 13 in, 95 lbZU/ZHU brochure (RBL), AY-XPC18ZU column | 33.5 × 27.9 × 13 in, 95 lbSHARP submittal, Jan. 2026 |
| Indoor unit W × H × D, weight | 41.4 × 12.4 × 9.8 in, 31 lbZU/ZHU brochure (RBL), AY-XPC18ZU column | 41.4 × 12.4 × 9.8 in, 31 lbSHARP submittal, Jan. 2026 |
| Electrical protection | 208-230 V; max. fuse 25 AZU/ZHU brochure (RBL), AY-XPC18ZU column | 208/230 V; max. fuse 25 A, breaker 20 A, outdoor MCA 16 ASHARP submittal, Jan. 2026 |
| Dehumidification | 2.4 L/h (5.1 pt/h, label not defined in the brochure)ZU/ZHU brochure (RBL), AY-XPC18ZU column | 2.4 L/h (5.1 pints/h)SHARP submittal, Jan. 2026 |
| Stated heating range | −27 to 24 °CZU/ZHU brochure (RBL), AY-XPC18ZU column | −30 to 24 °CSHARP submittal, Jan. 2026 |
| Stated cooling range | −10 to 46 °CZU/ZHU brochure (RBL), AY-XPC18ZU column | −10 to 46 °CSHARP submittal, Jan. 2026 |
The ZU brochure gives neither the pre-charged length nor the additional charge; the CU submittal does. Values declared by SHARP, not certified.
Questions about this job and these two series
Why compare the ZU1 with the SHARP CU rather than another brand?
Because it is the question someone who saw this job would ask: the same brand offers another 18,000 BTU wall series in the same cabinet. AirGreen offers both. Comparisons between brands are in the comparison hub.
Do they share the same certificate?
No. Each has its own AHRI certificate (213246053 for the ZU1, 217508915 for the CU). The SEER2, EER2 and HSPF2 seasonal ratings and cooling at 35 °C are identical; the published heating capacities differ, mostly below −8.3 °C.
What happens below −27 °C?
The ZU brochure states a heating range of −27 to 24 °C and the ZU1 certificate stops at −27.2 °C (11,500 BTU/h). The CU is stated down to −30 °C, where NEEP certifies 9,200 BTU/h. These are laboratory maximum values; the heat a home actually needs depends on the house.
Is the estimated cost really the same?
Yes, in the AirGreen method: it only uses the certified HSPF2 Region V and SEER2, and both values are identical (9.0 and 24.0). The differences in capacity in extreme cold are not part of this seasonal calculation.
Can the outdoor unit go under a balcony?
Minimum clearances are set by the SHARP installation manual; we could not read them in the documents consulted for this page. The diagram above only shows the room taken by the 27.9-inch-tall cabinet. Ask for the applicable clearances with your quote.
Is there financial assistance?
Programs such as Hydro-Québec’s LogisVert have their own equipment lists and conditions, which change. Check the current official list; this page gives no amount.
Why is this not a ranking?
Both series have the same certified seasonal ratings. They differ in a few published capacities and in the stated heating range. What matters depends on your house, your region and your use: the page shows the numbers and their sources, without a winner.
The values of both AHRI certificates, published by NEEP
| Item | SHARP ZU1 18,000 | SHARP CU 18,000 |
|---|---|---|
| Certificate | ||
| AHRI certificate · NEEP record | 213246053 · 507396 | 217508915 · 507388 |
| Refrigerant | R-32 (GWP 675, IPCC AR4; class A2L) | R-32 (GWP 675, IPCC AR4; class A2L) |
| ENERGY STAR | Yes; cold climate: yes | Yes; cold climate: yes |
| Seasonal efficiency | ||
| SEER2 | 24.0 | 24.0 |
| EER2 | 13.0 | 13.0 |
| HSPF2 Region IV | 11.0 | 11.0 |
| HSPF2 Region V | 9.0 | 9.0 |
| Cooling at 35 °C | ||
| Capacity min. / rated / max. | 6,000 / 18,000 / 21,600 BTU/h | 6,000 / 18,000 / 21,600 BTU/h |
| Heating at 8.3 °C | ||
| Capacity min. / rated / max. | 5,500 / 21,600 / 25,600 BTU/h | 5,500 / 21,600 / 27,000 BTU/h |
| COP min. / rated / max. | 5.76 / 4.22 / 3.68 | 5.76 / 4.22 / 3.68 |
| Max. capacity at 8.3 °C | 25,600 BTU/h | 27,000 BTU/h |
| Heating at −8.3 °C | ||
| Capacity min. / rated / max. | 7,500 / 22,000 / 22,000 BTU/h | 7,500 / 22,400 / 22,400 BTU/h |
| COP min. / rated / max. | 3.38 / 2.38 / 2.38 | 3.38 / 2.34 / 2.34 |
| Heating at −15 °C | ||
| Capacity min. / rated / max. | 5,800 / 18,000 / 18,000 BTU/h | 5,800 / 19,000 / 19,000 BTU/h |
| COP min. / rated / max. | 2.93 / 2.2 / 2.2 | 2.93 / 2.2 / 2.2 |
| Max. capacity at −15 °C | 18,000 BTU/h | 19,000 BTU/h |
| Coldest point of each certificate | ||
| Test temperature | −27.2 °C (−17 °F) | −30 °C (−22 °F) |
| Capacity min. / max. | 3,200 / 11,500 BTU/h | 2,200 / 9,200 BTU/h |
| COP min. / max. | 2.04 / 1.88 | 1.50 / 1.72 |
“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation.
Both are on the AirGreen website.
In-home estimate and written quote: we start from your house and your spot, balcony included.
Documents consulted
Data verified on November 17, 2026. Certified values: AHRI certificates published by NEEP. Declared values: SHARP documents cited, not certified. Programs, rates and documents can change.
SHARP and the other brands cited belong to their owners. Logos and images identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturer.
Photos: AirGreen and manufacturers, for identification.
A figure looks wrong? Write to us at sales@airgreen.ca.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).