Project

SHARP ZU1 wall heat pump installation in Montréal-Nord: the job, and how it compares with the SHARP CU (18,000 BTU)

An 18,000 BTU SHARP ZU1 installed under a balcony in Montréal-Nord, then compared figure by figure with the same-size SHARP CU: AHRI certificates, extreme cold, sound, installation and estimated cost.

By AirGreen Climatisation & Chauffage Admin15 min read
SHARP ZU1 wall heat pump installation in Montréal-Nord: the job, and how it compares with the SHARP CU (18,000 BTU)
SHARP ZU1 wall heat pump installation in Montréal-Nord: the job, and how it compares with the SHARP CU (18,000 BTU)
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

Comparison · Wall heat pump · 18,000 BTU

SHARP ZU1 and SHARP CU: same cabinet, two generations, figure by figure

AirGreen installed an 18,000 BTU SHARP ZU1 in a Montréal-Nord house. SHARP also offers the CU series in the same size, and AirGreen offers both. Their certified seasonal ratings and their dimensions are identical; their figures part ways when it gets very cold. Here is what the AHRI certificates and SHARP documents say, without a ranking.

SEER2 24.0 · bothHSPF2 Region V 9.0 · bothColdest certified point −27.2 °C ZU1 · −30 °C CUR-32 · both
AirGreen product card SHARP ZU1 18,000
SHARP

SHARP ZU1 18,000

AY-XP18ZU1 / AE-X18ZU1 · AHRI 213246053Installed in Montréal-NordSee the product page
Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. Here the ZU1 and the CU have the same HSPF2 Region V (9.0) and the same SEER2 (24.0): the calculation gives the same amount for both.

How this amount is calculated
  1. Heat to deliver over the winter. A zone whose heat loss reaches 18,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 18,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The project

An 18,000 BTU unit mounted under a balcony in Montréal-Nord

The owner wanted to heat and cool the house with a single wall unit, keeping heat through Québec winters, with an 18,000 BTU capacity and Wi-Fi control. The choice was a SHARP ZU1.

The photos show the outdoor unit on a wall bracket against the foundation, under a wooden balcony, next to a basement window. The refrigerant lines run in a white raceway along the wall. The 41.4-inch-wide indoor unit is connected with 1/4 and 3/8-inch lines, at 208-230 V.

What this job teaches someone deciding today: the SHARP CU series has exactly the same outdoor cabinet (33.5 × 27.9 × 13 in, 95 lb). The spot under this balcony would therefore suit either one in terms of size; the difference lies elsewhere, further down this page.

SHARP ZU1 outdoor unit on a wall bracket under a wooden balcony, Montréal-Nord
The outdoor unit under the balcony. Photo: AirGreen, Montréal-Nord.
SHARP ZU1 outdoor unit and line-set raceway along the foundation, Montréal-Nord
The lines, in a raceway along the foundation. Photo: AirGreen.

Under your balcony: the room the outdoor cabinet takes

Scale diagram, front view. Same cabinet for the ZU1 and the CU: 33.5 in wide, 27.9 in tall. Set your own measurements.

The minimum clearances required by SHARP are not legible in the documents consulted: this calculation does not say whether a spot complies, only how much room is left.

Same cabinet, two generations

Line by line: what is identical and what differs

Twenty measures taken from both certificates and both SHARP documents. Hide the identical lines to keep only the differences; the bars use the same scale for both units.

MeasureSHARP ZU1SHARP CUStatus
SEER2AHRI certificate, via NEEP24.024.0Identical
EER2AHRI certificate13.013.0Identical
HSPF2 Region IVAHRI certificate11.011.0Identical
HSPF2 Region VAHRI certificate; used for the cost estimate9.09.0Identical
Rated cooling at 35 °CNEEP18,000 BTU/h18,000 BTU/hIdentical
Max. heating at 8.3 °CNEEP25,600 BTU/h27,000 BTU/hDiffers
Max. heating at −8.3 °CNEEP22,000 BTU/h22,400 BTU/hDiffers
Max. heating at −15 °CNEEP18,000 BTU/h19,000 BTU/hDiffers
Coldest certified pointNEEP11,500 BTU/h at −27.2 °C9,200 BTU/h at −30 °CDiffers
Stated heating rangeZU brochure / CU submittal−27 to 24 °C−30 to 24 °CDiffers
Turndown ratioNEEP: max. capacity at −15 °C ÷ min. capacity at 8.3 °C3.273.45Differs
Indoor unit W × H × D, weightZU brochure / CU submittal41.4 × 12.4 × 9.8 in, 31 lb41.4 × 12.4 × 9.8 in, 31 lbIdentical
Outdoor unit W × H × D, weightZU brochure / CU submittal33.5 × 27.9 × 13 in, 95 lb33.5 × 27.9 × 13 in, 95 lbIdentical
Indoor sound, highest speedsound pressure, heating49 dB(A)49 dB(A)Identical
Indoor sound, medium speed (cooling)sound pressure40 dB(A)38 dB(A)Differs
Outdoor soundsound pressure52 dB(A)52 dB(A)Identical
Max. piping · max. height differenceZU brochure / CU submittal66 ft · 33 ft66 ft · 33 ftIdentical
RefrigerantNEEPR-32R-32Identical
ENERGY STAR Cold ClimateNEEPYesYesIdentical
Built-in Wi-FiZU brochure / CU submittalYesYesIdentical

13 identical lines out of 20; 7 differences, all related to heating except one medium-speed sound value.

NEEP’s turndown ratio is the maximum capacity at −15 °C divided by the minimum capacity at 8.3 °C (18,000 ÷ 5,500 and 19,000 ÷ 5,500). “Differs” does not mean better or worse: it is a gap between two published figures.

Extreme cold

Below −15 °C, every published value and its source

The certificates give one point at −15 °C and one colder point: −27.2 °C for the ZU1, −30 °C for the CU. In between, SHARP publishes maximum capacities at −20 and −25 °C in the ZU brochure and in the CU submittal.

The ZU brochure prints model AY-XPC18ZU / AE-X18ZU; its values are identical to the ZU1 certificate at −8.3, −15 and −27 °C. Manufacturer values are measured with 21.1 °C indoors (CU submittal) and are not part of the certificate.

Features

What each document names

A feature missing from a document is not necessarily missing from the unit: it is simply not named there.

Hot Gas Pipe defrost
ZU1 · named in the ZU brochureCU · named in the submittal

SHARP describes a system that keeps the bottom of the outdoor unit clear of ice by reusing heat from the circuit, without a separate heating element.

Wi-Fi and app
ZU1 · built-in Wi-Fi; app not namedCU · built-in Wi-Fi; Sharp Air app

The Montréal-Nord owner wanted this remote control.

Airflow direction: Coanda and Multi Space
ZU1 · named in the ZU brochureCU · named in the submittal (50 ft throw)

Automatic vertical louvers, manual horizontal louvers for both according to the documents.

Plasmacluster filter and cleaning
ZU1 · named in the ZU brochureCU · not named in the submittal

SHARP technology name only; this page attributes no effect to it.

Auto restart
ZU1 · named in the ZU brochureCU · not named in the submittal

After a power outage, the unit resumes its settings.

Sound

Indoor unit sound, speed by speed

Cooling values, where the only gap is; in heating, all five values are identical (49, 47, 41, 31 and 25 dB(A)). Outdoors: 52 dB(A) for both.

dB

How to read these figures · dB(A) of sound pressure: the lower the number, the quieter. Each dot is a published fan speed.

Why this is not a ranking · Neither document states the measuring distance or room; a 2 dB(A) gap at a single speed should be read with that caveat.

Measurements taken by each manufacturer with its own method; here, the same manufacturer for both.

Installation

The published limits for installing either one

ItemSHARP ZU1 18,000SHARP CU 18,000
Maximum piping length66 ft (20 m)ZU/ZHU brochure (RBL), AY-XPC18ZU column66 ft (20 m); minimum 10 ftSHARP submittal, Jan. 2026
Pre-charged lengthNot published by the manufacturer in the ZU brochure consulted25 ft (7.6 m)SHARP submittal, Jan. 2026
Maximum height difference33 ft (10 m)ZU/ZHU brochure (RBL), AY-XPC18ZU column33 ft (10 m)SHARP submittal, Jan. 2026
Liquid – gas diameters1/4 – 3/8 inZU/ZHU brochure (RBL), AY-XPC18ZU column1/4 – 3/8 inSHARP submittal, Jan. 2026
Additional refrigerant chargeNot published by the manufacturer in the ZU brochure consulted0.16 oz/ft beyond 25 ft; R-32, 49.0 oz factory chargeSHARP submittal, Jan. 2026
Outdoor unit W × H × D, weight33.5 × 27.9 × 13 in, 95 lbZU/ZHU brochure (RBL), AY-XPC18ZU column33.5 × 27.9 × 13 in, 95 lbSHARP submittal, Jan. 2026
Indoor unit W × H × D, weight41.4 × 12.4 × 9.8 in, 31 lbZU/ZHU brochure (RBL), AY-XPC18ZU column41.4 × 12.4 × 9.8 in, 31 lbSHARP submittal, Jan. 2026
Electrical protection208-230 V; max. fuse 25 AZU/ZHU brochure (RBL), AY-XPC18ZU column208/230 V; max. fuse 25 A, breaker 20 A, outdoor MCA 16 ASHARP submittal, Jan. 2026
Dehumidification2.4 L/h (5.1 pt/h, label not defined in the brochure)ZU/ZHU brochure (RBL), AY-XPC18ZU column2.4 L/h (5.1 pints/h)SHARP submittal, Jan. 2026
Stated heating range−27 to 24 °CZU/ZHU brochure (RBL), AY-XPC18ZU column−30 to 24 °CSHARP submittal, Jan. 2026
Stated cooling range−10 to 46 °CZU/ZHU brochure (RBL), AY-XPC18ZU column−10 to 46 °CSHARP submittal, Jan. 2026

The ZU brochure gives neither the pre-charged length nor the additional charge; the CU submittal does. Values declared by SHARP, not certified.

FAQ

Questions about this job and these two series

Why compare the ZU1 with the SHARP CU rather than another brand?

Because it is the question someone who saw this job would ask: the same brand offers another 18,000 BTU wall series in the same cabinet. AirGreen offers both. Comparisons between brands are in the comparison hub.

Do they share the same certificate?

No. Each has its own AHRI certificate (213246053 for the ZU1, 217508915 for the CU). The SEER2, EER2 and HSPF2 seasonal ratings and cooling at 35 °C are identical; the published heating capacities differ, mostly below −8.3 °C.

What happens below −27 °C?

The ZU brochure states a heating range of −27 to 24 °C and the ZU1 certificate stops at −27.2 °C (11,500 BTU/h). The CU is stated down to −30 °C, where NEEP certifies 9,200 BTU/h. These are laboratory maximum values; the heat a home actually needs depends on the house.

Is the estimated cost really the same?

Yes, in the AirGreen method: it only uses the certified HSPF2 Region V and SEER2, and both values are identical (9.0 and 24.0). The differences in capacity in extreme cold are not part of this seasonal calculation.

Can the outdoor unit go under a balcony?

Minimum clearances are set by the SHARP installation manual; we could not read them in the documents consulted for this page. The diagram above only shows the room taken by the 27.9-inch-tall cabinet. Ask for the applicable clearances with your quote.

Is there financial assistance?

Programs such as Hydro-Québec’s LogisVert have their own equipment lists and conditions, which change. Check the current official list; this page gives no amount.

Why is this not a ranking?

Both series have the same certified seasonal ratings. They differ in a few published capacities and in the stated heating range. What matters depends on your house, your region and your use: the page shows the numbers and their sources, without a winner.

Certified data

The values of both AHRI certificates, published by NEEP

ItemSHARP ZU1 18,000SHARP CU 18,000
Certificate
AHRI certificate · NEEP record213246053 · 507396217508915 · 507388
RefrigerantR-32 (GWP 675, IPCC AR4; class A2L)R-32 (GWP 675, IPCC AR4; class A2L)
ENERGY STARYes; cold climate: yesYes; cold climate: yes
Seasonal efficiency
SEER224.024.0
EER213.013.0
HSPF2 Region IV11.011.0
HSPF2 Region V9.09.0
Cooling at 35 °C
Capacity min. / rated / max.6,000 / 18,000 / 21,600 BTU/h6,000 / 18,000 / 21,600 BTU/h
Heating at 8.3 °C
Capacity min. / rated / max.5,500 / 21,600 / 25,600 BTU/h5,500 / 21,600 / 27,000 BTU/h
COP min. / rated / max.5.76 / 4.22 / 3.685.76 / 4.22 / 3.68
Max. capacity at 8.3 °C25,600 BTU/h27,000 BTU/h
Heating at −8.3 °C
Capacity min. / rated / max.7,500 / 22,000 / 22,000 BTU/h7,500 / 22,400 / 22,400 BTU/h
COP min. / rated / max.3.38 / 2.38 / 2.383.38 / 2.34 / 2.34
Heating at −15 °C
Capacity min. / rated / max.5,800 / 18,000 / 18,000 BTU/h5,800 / 19,000 / 19,000 BTU/h
COP min. / rated / max.2.93 / 2.2 / 2.22.93 / 2.2 / 2.2
Max. capacity at −15 °C18,000 BTU/h19,000 BTU/h
Coldest point of each certificate
Test temperature−27.2 °C (−17 °F)−30 °C (−22 °F)
Capacity min. / max.3,200 / 11,500 BTU/h2,200 / 9,200 BTU/h
COP min. / max.2.04 / 1.881.50 / 1.72

“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation.

Both are on the AirGreen website.

In-home estimate and written quote: we start from your house and your spot, balcony included.

(514) 316-2973Request a quote
Sources

Documents consulted

NEEP · SHARP ZU1 18,000Record 507396, AHRI certificate 213246053 (AY-XP18ZU1 / AE-X18ZU1), accessed November 17, 2026
NEEP · SHARP CU 18,000Record 507388, AHRI certificate 217508915 (AY-XPC18CU / AE-X18CU), accessed November 17, 2026
SHARP · Submittal Data Sheet AY-XPC18CU / AE-X18CUAE-X18CU_AY-XPC18CU-EN1, effective January 2026, accessed November 17, 2026
SHARP · ZU / ZHU brochure (French)Distributor RBL A/C, undated; AY-XPC18ZU / AE-X18ZU column; accessed November 17, 2026
Hydro-QuébecElectricity rates (April 1, 2026, Rate D, sec. 2.5)
NRCanHOT2000 climate map, Montréal Intl
In figures
The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
The unit

What the unit delivers when it is cold

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment