Installation d’une thermopompe multizone triple zone HITACHI airHome Multi à Laval-des-Rapides, Laval
Reading time: 19'

Installation of a HITACHI airHome Multi triple-zone multi-split heat pump in Laval-des-Rapides, Laval

Careful indoor integration in a home with an ornamental ceiling

In Laval-des-Rapides, we completed a HITACHI airHome Multi triple-zone multi-zone heat pump installation designed to improve comfort in three distinct areas of the property with a single outdoor unit. The project stood out because of an architectural constraint immediately visible in the photo: one of the wall-mounted units had to be installed in an older room with a detailed ceiling, prominent mouldings, and limited wall space above an interior opening.

This type of configuration requires much more than simply choosing a location. The unit must be able to distribute air effectively without interfering with the door opening, unnecessarily obscuring decorative elements, or creating an unsightly line-set route. We must also maintain the necessary clearances above and around the unit to allow air intake, filter removal, and future HVAC maintenance.

The photo shows a HITACHI indoor unit installed above a door, near a wall corner. The ceiling has mouldings that reduce the available vertical space. We therefore positioned the unit precisely to maintain sufficient clearance above the door while avoiding placing it too close to the ceiling.

The line set is routed toward the right side of the unit, then concealed in a vertical line-set cover that follows the angle of the wall. This solution minimizes the visual impact in a room where architectural details are particularly prominent.

Why a triple-zone heat pump was suitable for this property

A triple-zone multi-zone heat pump connects three indoor units to a single outdoor unit. Each unit serves a specific zone, making it possible to adjust comfort according to the actual needs of each room or floor.

In a Laval-des-Rapides property with several enclosed rooms, varying ceiling heights, or renovations completed at different times, it can be difficult to achieve an even temperature with a single wall-mounted unit. Heat does not automatically circulate through doors, hallways, and changes in level.

The triple-zone configuration can be used, among other things, to treat separately:

  • a main living area;
  • a bedroom or office;
  • a room on another floor;
  • an extension;
  • a zone more exposed to sunlight;
  • a room far from the existing heating system.

Each indoor unit compatible with the HITACHI airHome Multi platform can be adjusted individually. Occupants can change the temperature, fan speed and several other settings in one zone without imposing exactly the same settings on the other two. Some units can be turned off while the others remain operating.

However, the operating principle common to multi-zone systems must be respected. In summer, the system operates in cooling mode; the indoor units can then be set to cooling, dehumidification or fan mode. In winter, the system operates in heating mode; the indoor units can be set to heating or fan mode. Therefore, one zone cannot be actively heated while another is being cooled by the same outdoor unit.

Installation above a door: a compact but demanding solution

The space above a door is sometimes the best location for a wall-mounted air conditioner when the other walls are occupied by windows, furniture, artwork, bookcases or decorative elements.

However, this solution can become problematic if chosen without analysis. The unit must be installed high enough not to obstruct passage, but it must not be placed directly against the ceiling. Its louver must be able to open freely and direct air into the room rather than straight into the door frame.

Several factors had to be coordinated on this project:

  • the width of the indoor unit;
  • the height of the frame;
  • the proximity of the ceiling molding;
  • the angle of the wall on the right;
  • the drain route;
  • the refrigerant line routing;
  • access to the front panel;
  • the main direction of the airflow.

The unit was functionally centered above the opening, without attempting to follow only the door’s aesthetic axis. In HVAC installation, perfect symmetry is not always the top priority. We must first ensure clearance, drainage, airflow and service access.

The distinctive feature of the ornamental ceiling

The ceiling trim adds character to the room, but it complicates the work. A wall-mounted unit must draw air in through its upper section. If it is too close to a cornice or deep trim, airflow may be restricted.

We must also avoid unnecessarily damaging the existing details. The holes, anchors, and conduit outlet are therefore positioned with great precision.

The trim follows several curves and changes in level. An approximate installation could have produced a visually unbalanced result or forced the unit to be installed too low. Instead, we used the available space between the frame and the ceiling, taking the actual shape of the decorative elements into account.

This attention to detail is particularly important in older homes in Laval and Montréal, where ceilings may have plaster cornices, ceiling medallions, trim added during previous renovations, or surfaces that are not perfectly straight.

A line set cover adapted to the corner of the room

The line set cover visible to the right of the unit follows the wall up to the ceiling, then continues into the corner. It protects and conceals several components:

  • the two refrigerant lines;
  • the thermal insulation;
  • the communication cable;
  • the indoor unit’s power supply, depending on the configuration;
  • the condensate drain.

In an indoor installation, the line set cover serves more than an aesthetic purpose. It protects the insulation from impacts, reduces the risk of crushing, and makes it easier to inspect the route during service.

The corner of the room was a logical route here, but we had to work around the trim. The upper connection was adjusted to maintain a continuous path despite the ceiling’s unusual geometry.

A common mistake is to force the line set cover against uneven trim, leaving visible gaps or creating stress in the finishing pieces. Instead, we adapt the layout to the building, using transitions that remain accessible.

The importance of drainage in this position

In cooling mode, the indoor unit removes moisture from the air. This water is collected in a drain pan and then discharged through a drain.

When the unit is located above a door, any slope error can quickly become visible. An improperly positioned drain can cause:

  • water leaking indoors;
  • marks on the wall or trim;
  • water accumulating in the drain pan;
  • gurgling noises;
  • odors;
  • a protective shutdown depending on the type of installation.

We therefore pay particular attention to the drain slope along its entire route. When continuous gravity drainage is impossible, a condensate pump may be considered, but natural drainage remains preferable whenever it can be properly implemented.

The photo does not allow us to confirm the complete drain route beyond the pipe cover. However, it shows that the lines exit on the right side, allowing the refrigerant circuit and condensate drainage to be coordinated within the same finish.

A HITACHI platform designed for several types of indoor zones

The HITACHI airHome Multi range includes outdoor units from 18,000 to 42,000 BTU/h that can power two to five indoor units. It uses Inverter technology and R32 refrigerant. The manufacturer’s brochure indicates efficiency of up to a TRÉS2 of 23.0 and a CPSC2-5 of 7.85, depending on the selected combination.

For a three-zone configuration, the corresponding platform shown in the documentation is the RAM-G24N3HAA, designed for three indoor connections.

The photo does not show the outdoor unit’s label or the precise models of the three indoor units. We therefore cannot confirm the exact combination installed based solely on the image. However, the documentation makes it possible to describe the technical specifications of the series’ three-zone platform.

Capacity and performance of the three-zone platform

The RAM-G24N3HAA has a rated cooling capacity of 24,000 BTU/h and a rated heating capacity of 24,000 BTU/h. Depending on the combination, its cooling capacity can modulate within an approximate range of 7,000 to 28,000 BTU/h, while the heating capacity can reach up to 26,200 BTU/h.

For a ductless configuration, the documentation indicates, among other things:

  • a TRÉ2 of 12.5;
  • a TRÉS2 of 22.0;
  • a CPSC2 of 9.5 in Region 4;
  • a CPSC2 of 7.8 in Region 5;
  • a COP of 3.5 at 8 °C;
  • a maximum heating capacity of 18,500 BTU/h at -15 °C;
  • a maximum heating capacity of 13,000 BTU/h at -20 °C.

These values show why a heat pump should not be evaluated solely based on its rated capacity. As the outdoor temperature decreases, the available output changes. The existing heating system must therefore be taken into account when we assess requirements during very cold periods.

Operation down to -20 °C

The manufacturer indicates a heating operating range down to -20 °C for this series. The cooling range extends from -10 °C to 46 °C.

For a property in Laval-des-Rapides, this low-temperature operating capacity allows the heat pump to be used throughout a large portion of the heating season. However, it does not mean that the unit delivers its full nominal capacity at -20 °C.

We therefore assess:

  • the heat losses of each zone;
  • the building’s insulation;
  • the area served;
  • the type of windows;
  • exposure to wind;
  • the available supplementary heating;
  • occupancy habits;
  • the expected comfort level.

This analysis is essential in a triple-zone system because the three indoor units share the outdoor unit’s available capacity.

Three zones do not mean three times the nominal capacity

A common mistake is to assume that an outdoor unit rated at 24,000 BTU/h and connected to three 9,000 BTU/h indoor units will automatically produce a total of 27,000 BTU/h at all times.

In a multi-zone system, the allowable indoor capacities may exceed the outdoor unit’s nominal capacity in certain combinations specified by the manufacturer. The heat pump then distributes its output according to demand. If only one zone requires little heating, the system can modulate at low speed. If all three zones simultaneously require their maximum capacity, the outdoor unit distributes the available output.

Sizing must therefore be carried out for the building as a whole, not just room by room. At AirGreen, we check the complete combination before installation to avoid an imbalance between one large, high-demand area and two small secondary areas.

Several types of compatible indoor units

The airHome Multi series allows several indoor unit formats to be combined:

  • airHome 400, a wall-mounted unit;
  • airHome 650, a wall-mounted unit with smart features;
  • airHome Floor, a floor console;
  • airHome Mini Cassette, a four-way ceiling unit;
  • airHome Ducted, a concealed unit connected to short ducts.

Available capacities generally range from 7,000 to 24,000 BTU/h, depending on the indoor model.

In this installation in Laval-des-Rapides, the visible unit is a wall-mounted model. This choice makes sense for a room with limited technical space in the ceiling, where a ducted unit would have required more invasive work.

In other areas of the same house, the choice could be different. A floor console may suit an attic room; a mini-split cassette can be used in an open-plan area; a concealed ducted unit can be hidden in a dropped ceiling.

Sound level of wall-mounted units

The sound level depends on the series, capacity, and fan speed. The airHome 650 wall-mounted units presented in the brochure can operate at as little as approximately 27 dB(A), while several airHome 400 units can operate at as little as approximately 29 dB(A).

This operating level is particularly useful for bedrooms, offices, and rooms where occupants want to limit mechanical noise.

Positioning also affects acoustic comfort. An indoor unit placed directly facing a bed or workstation may be more noticeable, even at low speed. We therefore analyze the louver orientation and furniture layout before securing the unit.

Air quality functions

Depending on the selected indoor unit, the system may include various functions:

  • PM2.5 activated carbon filter;
  • ViroSense S filter;
  • FrostWash technology;
  • Mold Guard function;
  • R32 refrigerant leak sensor.

The FrostWash function uses a freezing and thawing process to help remove contaminants accumulated on the coil. The Mold Guard function circulates air for approximately 60 minutes after cooling or dehumidification to dry the internal components.

These functions can reduce moisture accumulation, but they do not replace periodic filter cleaning or thorough maintenance of the fan wheel and condensate pan.

R32 refrigerant leak sensor

Compatible indoor units include a sensor that can issue an alert in the event of a refrigerant leak. Depending on the configuration, the alarm may come directly from the indoor unit or from an optional receiver assembly. An airPoint Room H700 wall controller can also provide an additional alert.

The presence of this sensor does not eliminate the need for rigorous refrigerant system installation. Connections must be prepared, tightened, and checked according to the manufacturer's procedures.

The invisible steps that determine project quality

Once the indoor units have been secured and the lines connected, several essential tasks still need to be completed.

Checking refrigerant connections

Each indoor unit has connections that must be carefully prepared. Improper flaring or incorrect tightening can cause a slow leak that is difficult to detect at first.

Leak test

The circuit must be tested using the appropriate method to confirm that there are no leaks before commissioning.

Evacuation

The vacuum removes air and moisture from the lines. This step protects the compressor oil and contributes to system reliability.

Checking the drains

Each zone has its own condensate drain. We check the flow before fully closing the covers.

Starting up the three zones

We operate the units, verify their communication with the outdoor unit, and check their response to commands.

Explaining the system to occupants

We explain, in particular:

  • how to select the correct mode;
  • why the zones must share the same overall mode;
  • how to clean the filters;
  • how to adjust the louvers;
  • how to use the fan speeds;
  • when to request service.

Piping constraints for the triple-zone model

For the RAM-G24N3HAA model, the documentation specifies:

  • a maximum total piping length of 200 feet;
  • a maximum total height of 66 feet;
  • a maximum length of 82 feet per indoor unit;
  • a minimum length of 16 feet;
  • a maximum elevation difference of 16 feet between the indoor units.

The outdoor unit has three 1/4-inch liquid connections and three 3/8-inch gas connections.

These limits provide some flexibility in a multistory home, but they must be verified during the planning stage. An indoor unit may seem well placed in a room while requiring an overly complex refrigerant line route to the outdoors.

Electrical data for the triple-zone platform

The RAM-G24N3HAA model operates at 208–230 V, single-phase, 60 Hz. The technical data sheet specifies a minimum circuit ampacity of 19 A and maximum overcurrent protection of 35 A.

These values apply to the model described in the brochure. The nameplate on the equipment actually installed remains the final reference on site.

We check, in particular:

  • the panel capacity;
  • the conductor gauge;
  • the required circuit breaker;
  • the presence of an outdoor disconnect switch;
  • the wiring route;
  • the compliance of the connections.

Mistakes to avoid in such a tight indoor installation

Placing the unit too close to the ceiling

Insufficient clearance above the unit can restrict air intake and make filter removal more difficult.

Failing to account for the door opening

The shutter, door, or trim must not interfere during use.

Choosing the location solely to hide the lines

The routing should be discreet, but air-distribution quality remains the priority.

Installing the unit without checking the wall

Studs, masonry, old repairs, and existing conduits must be located before drilling.

Forcing the line-set cover against the moldings

An improperly fitted rigid finish can warp or leave visible openings.

Directing the airflow straight toward an occupied area

A constant draft over a bed, armchair, or desk can become uncomfortable.

Undersizing the large zone to favor the smaller ones

In a triple-zone system, capacity distribution must reflect the building’s actual loads.

An installation that respects the character of the room

The unit shown in the photo is integrated into a complex space without concealing the main moldings or encroaching on the door frame. The line-set cover follows the angle of the room, limiting its visual presence.

The result remains clearly identifiable as a mechanical installation, but it is organized and consistent with the existing constraints. In older properties in Laval-des-Rapides, it is rarely possible to make all components invisible without undertaking major renovations. Our objective is therefore to find a balance between:

  • performance;
  • ease of maintenance;
  • drainage quality;
  • protecting the lines;
  • visual integration;
  • preserving the architectural details.

Three comfort zones with a single outdoor unit

This HITACHI airHome Multi triple-zone multi-zone heat pump installation in Laval-des-Rapides makes it possible to condition three areas independently while limiting the number of outdoor units.

The visible wall-mounted unit clearly illustrates the level of precision required when space is limited. The door, decorative ceiling, moldings, and wall angle all influenced the final placement.

At AirGreen, we apply the same level of rigor to our multi-zone heat pump, wall-mounted air conditioner, central system, and HVAC maintenance services in Laval-des-Rapides, Laval, Montréal, Longueuil, the North Shore, and the South Shore.

A good heat pump is not defined solely by its brand or BTU capacity. Its performance depends on the selected combination, the load of each zone, the routing of the lines, drainage, the quality of the connections, and the precision of the indoor installation.