Installation d’une thermopompe murale Fujitsu AIRSTAGE Altair 500 à Venise-en-Québec : unité extérieure sur support mural et installation CVAC soignée
Reading time: 15'

Installation of a Fujitsu AIRSTAGE Altair 500 wall-mounted heat pump in Venise-en-Québec: outdoor unit on a wall bracket and meticulous HVAC installation

In Venise-en-Québec, a Fujitsu Altair 500 installed to stay clear of the ground and remain easy to maintain

In this installation completed in Venise-en-Québec, one element immediately draws our attention: the outdoor unit of the Fujitsu AIRSTAGE Altair 500 wall-mounted heat pump was not simply placed on a ground-level pad. We positioned it on a metal wall bracket, at a sufficient height to keep it clear of the ground, leaves, water, and accumulations that can form around a residence over the seasons.

The project photograph also shows several characteristic features of a well-organized HVAC installation: the Fujitsu unit is securely supported against the building, the refrigerant lines enter neatly from the right side through a white exterior line-covering duct, an electrical disconnect box is installed nearby, and vibration-dampening elements are visible between the unit and its bracket.

These details, which are often less eye-catching than the brand choice or the number of BTUs, are precisely what contribute to the quality of a wall-mounted heat pump installation.

For this project, we installed a Fujitsu AIRSTAGE Altair 500, a single-zone heat pump from the H series that uses R-32 refrigerant and an Inverter-technology compressor. The range includes several capacities, from 9,000 to 33,000 nominal BTU/h in cooling, depending on the model, and Fujitsu states a heating operating range down to -15 °C.

Why we chose a wall bracket for the outdoor unit

The choice between a ground pad and a wall bracket should never be made automatically. Each building has its own constraints.

In this installation in Venise-en-Québec, the wall bracket offers several practical advantages.

Keep the unit above ground level

The photo clearly shows that the outdoor unit is installed several inches above the adjacent surface. This creates space beneath the heat pump and facilitates drainage of water produced by defrosting in winter.

A heat pump naturally produces water during its defrost cycles. If the unit is placed too close to the ground and this water refreezes directly beneath the chassis, ice buildup can gradually reach the bottom of the unit.

We therefore always aim to create an environment where the outdoor unit can breathe and where water has room to drain away.

Reducing contact with leaves and debris

In the photo of this installation, leaves can be seen on the ground around the residence. This clearly illustrates the benefit of keeping the outdoor unit elevated.

Leaves, small debris, and dirt must not accumulate against the outdoor heat exchanger. A clogged heat exchanger receives less air, and a heat pump depends directly on adequate airflow to transfer heat efficiently.

The wall bracket does not replace maintenance, but it helps keep the unit in a more open area.

Making future service easier

A properly installed unit must also be serviceable.

During HVAC maintenance, our technicians must be able to access the heat exchanger, service panels, electrical connections, and refrigerant fittings. The positioning shown here leaves the unit accessible from the front and from the side where the main connections are located.

This accessibility is important both for preventive cleaning and for any necessary diagnostics.

A compact outdoor installation despite the proximity of a window

The available space was not unlimited. The unit is located directly in front of part of a window and near an exterior corner of the building.

In a situation like this, the installation must account for several constraints simultaneously:

  • the actual width of the outdoor unit;
  • the clearances required around the heat exchanger;
  • the location of the piping;
  • cable routing;
  • the ability to securely fasten the bracket;
  • access to the electrical disconnect;
  • winter drainage;
  • vibration;
  • future service access.

The Fujitsu Altair 500 line uses relatively compact outdoor units. Depending on capacity, Fujitsu lists widths ranging from 26 1/8 in. for the smallest capacities to approximately 37 in. for the largest units in the series.

In a project where we have to work between a window, a wall corner, and existing electrical equipment, a difference of a few inches can considerably affect the final configuration.

The line-hide cover: a small detail that significantly improves the finish

To the right of the outdoor unit, the photograph shows the white piping cover descending vertically along the wall.

This type of cover generally houses the connections required for the system to operate: insulated refrigerant lines, communication wiring, and, depending on the selected configuration, other installation-related components.

We place great importance on the route of this line-hide cover.

A disorganized, unnecessarily long route or poorly aligned fittings can detract from the building’s appearance and make future service work more complicated.

Here, the route follows a clear vertical line and connects directly to the outdoor unit’s connection area.

For a HVAC installation in Venise-en-Québec, as with our projects in Montreal, Laval, Longueuil, on the North Shore or the South Shore, we consider the exterior finish an integral part of the work, not a secondary step.

What the Fujitsu AIRSTAGE Altair 500 technically brings to this installation

A single-zone range operating on R-32

The Altair 500 series is a range of single-zone wall-mounted systems. An indoor unit is therefore paired with a corresponding outdoor unit.

The combinations presented in Fujitsu’s documentation are:

  • ASUH09KPAS + AOUH09KPAS1
  • ASUH12KPAS + AOUH12KPAS1
  • ASUH18KPAS + AOUH18KPAS1
  • ASUH24KPAS + AOUH24KPAS1
  • ASUH30KPAS + AOUH30KPAS1
  • ASUH36KPAS + AOUH36KPAS1.

The nameplate is not clear enough in the photo to confirm the exact capacity of the unit installed in Venise-en-Québec without ambiguity. We therefore prefer not to arbitrarily assign a tonnage or BTU rating to this unit.

This is an important distinction. The name Altair 500 refers to an entire range, not a single capacity.

From 9,000 to 33,000 rated BTU/h in cooling mode

The technical data sheet lists the following rated cooling capacities:

  • 09KPAS1 : 9,000 BTU/h
  • 12KPAS1 : 12,000 BTU/h
  • 18KPAS1 : 18,000 BTU/h
  • 24KPAS1 : 22,000 BTU/h
  • 30KPAS1 : 30,000 BTU/h
  • 36KPAS1 : 33,000 BTU/h

In heating mode, the stated rated capacities are respectively 10,000, 14,000, 18,000, 24,000, 30,000, and 34,000 BTU/h.

This capacity modulation illustrates why sizing must be taken seriously.

Installing a 30,000 or 33,000 BTU heat pump in a space that requires much less power is not an improvement. Conversely, selecting an undersized unit can reduce comfort when heating demand increases.

We assess the floor area, room layout, insulation level, windows, exposure, and actual heating and cooling needs before recommending a capacity.

Inverter technology: matching output to actual demand

Inverter technology allows the compressor to modulate its operation.

Rather than operating continuously at full power and then stopping, the system gradually adjusts its capacity according to demand.

This helps maintain a more consistent temperature and reduces abrupt on-off cycles.

Fujitsu’s documentation also presents a low-noise outdoor operating mode, along with various energy-management and comfort modes.

In a residential installation where the outdoor unit is located relatively close to the building, this type of modulated operation provides a significant benefit.

Heating down to -15 °C

Fujitsu specifies the Altair 500 series for a heating operating range of -15 °C to 24 °C, for all six capacities presented in the technical data sheet.

This information must, however, be interpreted correctly.

A minimum operating temperature is not the same as a guarantee of rated capacity at that temperature. Like all air-source heat pumps, available capacity varies as the outdoor temperature decreases.

For a homeowner comparing an Altair 500 with a Fujitsu heat pump specifically designed for even lower temperatures, we therefore consider the building’s overall needs rather than a single temperature shown in a brochure.

R-32: a lower GWP than R-410A

The Altair 500 uses R-32.

In its documentation, Fujitsu compares a global warming potential of 675 for R-32 with 2,088 for R-410A, representing, depending on the reference used, a 68% reduction in GWP. The manufacturer also indicates that R-32 systems require less refrigerant to achieve their specified performance.

For the installer, switching to R-32 also involves procedures and practices adapted to the new refrigerant.

The quality of the connections, copper preparation, leak testing, evacuation, and commissioning must be carried out precisely.

Choosing a good machine cannot compensate for poor preparation of the refrigerant circuit.

Different piping diameters depending on capacity

One of the most important technical details of the Altair 500 concerns the refrigerant piping dimensions.

Fujitsu states:

  • 9,000 and 12,000 BTU: 1/4 in. liquid + 3/8 in. gas;
  • 18,000 and 22,000 nominal BTU: 1/4 in. liquid + 1/2 in. gas;
  • 30,000 and 33,000 nominal BTU: 3/8 in. liquid + 5/8 in. gas.

This becomes particularly important when replacing an older heat pump.

We never assume that the existing copper tubing is automatically suitable for the new equipment. The dimensions, condition of the lines, and compatibility must be verified.

The maximum permitted length also varies according to capacity: up to 66 ft on the 9,000 and 12,000 models, 98 ft on the 18,000 and 24KPAS1 models, and up to 164 ft on the 30,000 and 36KPAS1 models.

The wall bracket and vibration transmission

In the photo from Venise-en-Québec, we can distinguish elements placed between the unit’s feet and the metal support.

This mechanical separation is important.

A compressor and a fan necessarily create small vibrations when operating. If the outdoor unit is mounted directly to a structure without sufficient precautions, some of these vibrations may be transmitted to the wall.

We therefore seek to achieve all of the following simultaneously:

  1. a solid mounting;
  2. a perfectly stable unit;
  3. reduced vibration transmission;
  4. an adequate level to ensure proper operation and drainage.

This work is particularly important when the outdoor unit is mounted to the house rather than placed on an independent base.

An accessible electrical disconnect nearby

To the right of the heat pump, the photo also shows an outdoor electrical disconnect enclosure.

Its location close to the appliance makes it easier to electrically isolate the system when service work is required.

The Altair 500 series operates at 208 to 230 V, 60 Hz, single-phase. The breaker requirements listed in the documentation vary by capacity:

  • 15 A for the 09KPAS1, 12KPAS1, and 18KPAS1;
  • 20 A for the 24KPAS1;
  • 30 A for the 30KPAS1 and 36KPAS1;

Once again, simply knowing the name “Altair 500” is not enough to prepare the electrical supply. The exact model number must be confirmed.

Indoor operation as low as 19 dB(A)

The quality of a wall-mounted heat pump is also assessed inside the home.

For the 9,000 and 12,000 BTU models, Fujitsu indicates an indoor sound level as low as 19 dB(A) in cooling mode, in quiet mode. The minimum level then varies according to the larger capacities: 26 dB(A), 31 dB(A), or 32 dB(A), depending on the model.

This illustrates why we avoid using a single acoustic value to describe the entire range.

Noise performance depends on the selected capacity and fan speed.

ProCore coils and Hydro Fin fins

Fujitsu documentation also highlights ProCore copper coils in the indoor unit, as well as a heat exchanger using Hydro Fin fins to improve corrosion resistance.

These features are beneficial for durability, but proper maintenance remains essential.

The indoor unit’s filters are washable. They must remain clean to maintain airflow. Over time, the evaporator, fan wheel, and condensate drain pan may also require more thorough wall-mounted heat pump cleaning.

A well-maintained unit is better able to retain its performance and air circulation quality.

Wi-Fi available with a compatible adapter

The Altair 500 series can also be integrated with various control solutions.

Fujitsu specifically indicates that the AIRSTAGE app can be used with a compatible USB WLAN adapter, along with several optional controllers and interfaces. The documentation also mentions BACnet and Modbus integration options.

However, it is important to distinguish between Wi-Fi compatibility and Wi-Fi being included as standard.

Depending on the selected configuration, an additional accessory may be required.

ENERGY STAR and financial incentives: verify the exact model

The specification sheet associates several models in the Altair 500 lineup with different ENERGY STAR designations, including some categories related to cold climates. These classifications are not identical from one capacity to another.

For this reason, when a homeowner wants to take advantage of a subsidy or rebate, we always verify the exact combination of the indoor and outdoor units as well as the program criteria applicable at the time of the project.

A brand logo or the series' commercial name is not enough to confirm that a specific unit is eligible.

What this Venise-en-Québec installation shows better than a specification sheet

A brochure lets you compare the SEER2, CPSC2, BTUs, sound level, and maximum piping length. A real installation shows something else.

It shows whether the contractor thought carefully about the location.

It shows whether the outdoor unit remains off the ground.

It shows how the lines were routed.

It shows whether the electrical installation remains accessible.

It shows whether the work respects both the building and the equipment.

On this Fujitsu heat pump installation in Venise-en-Québec, the outdoor unit is neatly positioned against the building on a wall bracket that keeps it above the ground. The line set cover follows a compact, direct route. The electrical disconnect remains accessible. The connections are grouped on the same side of the unit rather than spread around the wall.

This is the kind of consistency we strive for at AirGreen.

Whether the project is in Venise-en-Québec, Montreal, Laval, Longueuil, the North Shore, or the South Shore, our work does not consist solely of getting a heat pump up and running. We must choose the right capacity, plan the piping route, meet electrical requirements, position both units correctly, and prepare the system so it is as easy to maintain as it is to use.

The Fujitsu AIRSTAGE Altair 500 offers an appealing combination of inverter technology, R-32 refrigerant, multiple capacities, quiet operation, and a compact outdoor design. But the difference between a heat pump that is simply installed and a durable, professional HVAC installation comes down to the details visible on a job like this.

Leave a comment